                                                                  Page 14 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No such components 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
F501 approved. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : F501: T5A L 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : Soldered in the power board, 
only one location for fuse. 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
Tools required. 
 
Pass 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such parts 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 
N/A 
14.6 Switches 
No 
switch 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
         
 N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
         
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
         
 N/A 
 
                                                                  Page 15 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
         
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
         
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
         
 N/A 
 
Socket outlet current marking correct 
         
 N/A 
14.7 Safety 
interlocks 
No such parts 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
         
 N/A 
14.8 
Voltage setting devices 
No such parts 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
         
 N/A 
14.9 Motors 
 
N/A 
14.9.1 
Endurance test on motors 
Only low voltage DC servo 
motor in DVD loader 
N/A 
 
Motor start test 
         
 N/A 
 Dielectric 
strength 
test 
         
 N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
         
 N/A 
14.9.3 
Protection against moving parts 
         
 N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 
and B.10 of IEC 60950, Annex B 
         
 N/A 
14.10 Batteries 
 Pass 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
Only non-rechargeable alkali 
batteries in IR remote 
controller. 
Pass 
14.10.2 No 
possibility of recharging non-rechargeable 
batteries 
No recharging circuit in 
apparatus 
N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
No recharging circuit in 
apparatus 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
No lithium battery 
N/A 
14.10.4 
Battery mould stress relief 
No such battery 
N/A 
14.10.5 
Battery drop test 
No such battery 
N/A 
14.11 Optocouplers 
Separately 
approved, 
see 
appended table 
Pass 
 
                                                                  Page 16 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Optocouplers comply with Cl. 8 
Internal DTI >0.40mm min. 
Pass 
 
Internal and external dimensions to 13.1. or 
alternatively 13.6 (jointed insulation) 
int./ext. Cl. &Cr.  4mm min. / 
≥6.0mm min. 
Pass 
14.12 
Surge suppression varistors 
VDE approved 
Pass 
 
Comply with IEC 61051-2 
 
Pass 
 
Not connected between mains and accessible 
parts except for earthed parts of permanently 
connected apparatus 
 Pass 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12 
 Pass 
 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
 Pass 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
 
No risk of insertion in mains socket-outlets 
 
Pass 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-
outlets 
         
 N/A 
15.2 
Provision for protective earthing 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment 
Class II 
N/A 
 
Class I supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 
N/A 
 
Protective earth conductors correctly coloured 
 
N/A 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 
N/A 
 
Protective earth terminal resistant to corrosion 
 
N/A 
 
Earth resistance  test: < 0,1 
Ω at 25 A ................... :  
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 Pass 
 
                                                                  Page 17 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
15.3.1 
Adequate terminals for connection of permanent 
wiring 
 N/A 
15.3.2 
Reliable connection of non-detachable cords: 
 
N/A 
 
Not soldered to conductors of a printed circuit 
board 
No. Pass 
 
Adequate clearances and creepage distances 
between connections should a wire break away 
 Pass 
 
Wire secured by additional means to the conductor Mating lock connector 
Pass 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar 
         
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal 
prior to soldering or held in place by additional 
means 
 
N/A 
 
Clamping of conductor and insulation if not 
soldered or held by screws 
Mating lock connector, both the 
conductor and insulation are 
crimped. 
Pass 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current 
of the equipment 
         
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by 
table 16 
         
 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure 
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened 
 
N/A 
 
Terminals adequately fixed to avoid loosening 
when the clamping is tightened or loosened and 
stress on internal wiring is avoided 
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic 
 Pass 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other 
 N/A 
 
Terminals located and shielded: test with 8 mm 
strand 
 
N/A 
15.4 
Devices forming a part of the mains plug 
No such device 
N/A 
15.4.1 
No undue strain on mains socket-outlets 
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs 
 
N/A 