Harman Kardon HS 200 (serv.man5) EMC - CB Certificate ▷ View online
Page 26 of 63 Report No. SH09051259-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No such switch used.
N/A
Amendment 1 to EN60065, 7th edition
5.4.1
A warning that batteries (battery pack or batteries
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
N/A
Special stability warning for the apparatus with
CRT
CRT
Warning: the CRT in this product employs a
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
N/A
8.7 Void
N/A
8.8
For requirements for non-separable thin sheet
insulation in two or more layers, see 8.22.
insulation in two or more layers, see 8.22.
N/A
8.22
Requirements for non-separable thin sheet
insulation in two or more layers
insulation in two or more layers
N/A
15.2
Delete the paragraph: In supply apparatus of
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
N/A
18.1
Protective film as part of the implosion protection
system: all edges covered by the enclosure of the
apparatus
system: all edges covered by the enclosure of the
apparatus
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
N/A
20.1
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
Pass
b) Exemption for small components as defined in
20.1 excluding metal, glass and ceramic.
20.1 excluding metal, glass and ceramic.
Pass
Page 27 of 63 Report No. SH09051259-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.1
TABLE: rated current/power consumption
Pass
Model
Input voltage
(V)
(V)
Rated
current
(mA)
current
(mA)
Measured
current
(mA)
current
(mA)
Rated
power (W)
power (W)
Measured
power (W)
power (W)
condition/status
240 -
366 300 43.0
HS 200
100 -
720 300 41.5
Normal DVD playing
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-by
0W/2.1W max.
—
Position of the functional switch (W) ...................... :
On
—
Room temperature t1 (°C) ...................................:
20.0
Room temperature t2 (°C) ...................................:
20.0
Operating conditions
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours
until steady condition reached. Ambient 20
until steady condition reached. Ambient 20
o
C.
Un (V)
In (mA)
Pn (W)
Pout (V / mA)
264 347
43.6
N.A.
90 785
41.5
N.A.
Loudspeaker impedance (Ω) ................................. : 6Ω X 2
—
Several loudspeaker systems
2 channel speakers
Pass
Marking of loudspeaker terminals
Printed on rear enclosure
Pass
dT (K)
monitored point:
264
90
Permitted dT (K)
Power cord
25.1
27.4
60
Connector
25.9
27.7
-
PCB near RZ503
36.8
53.3
85
CY502 (Y1 capacitor)
23.3
23.5
60 (85-25)
CX502 (X2 capacitor )
29.6
30.5
60 (85-25)
Page 28 of 63 Report No. SH09051259-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Operating conditions
CX503 (X2 capacitor )
30.6
30.4
60 (85-25)
Winding of LF502
31.3
34.5
75*
PCB near BD501
30.7
30.7
85
PCB near Q509
35.4
29.7
85
PCB near U503
34.7
29.7
85
EC502 (electrolytic capacitor)
32.0
29.6
80 (105-25)
Winding of T502
44.3
37.9
75*
Bobbin of T502
40.3
35.7
--
PCB near T502
39.4
34.7
85
CY504 (Y1 capacitor)
35.1
32.0
60 (85-25)
Winding of T503
43.3
37.1
75*
Bobbin of T503
40.4
35.1
--
PCB near T503
37.9
33.4
85
CY503 (Y1 capacitor)
35.8
31.9
60 (85-25)
PCB near D515
39.1
33.7
85
EC518 (electrolytic capacitor)
37.9
32.3
80 (105-25)
PCB of amplifier board
43.7
42.7
85
PCB of main board
36.9
36.0
85
Enclosure (metallic)
15.5
14.7
40
Enclosure (non-metallic)
7.3
7.0
60
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω)
dT (K)
required
dT (K)
dT (K)
Insulation
class
class
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
100
2
Between parts separated by basic or supplementary insulation
100
2
Page 29 of 63 Report No. SH09051259-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between parts separated by double or reinforced insulation
4.3
4
Between parts of T502 separated by basic or supplementary
insulation
insulation
100 2
Between parts of T503 separated by basic or supplementary
insulation
insulation
100 2
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Between parts separated by basic or supplementary insulation
2120Vp
No
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of T502 separated by basic or supplementary
insulation
insulation
2542Vp No
Between parts of T503 separated by basic or supplementary
insulation
insulation
2586Vp No
11.2
TABLE: summary of fault condition tests
Pass
Model/type of power supply .................................: --
—
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240
Ambient temperature (
o
C) ...................................... : 24
—
No.
Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1.
U502:
secondary
SC 264
10
min.
F501
0.063
P=1.7W. No high
temperature, no hazard.
temperature, no hazard.
Pass
2.
R531 SC
264
10 min.
F501
0.062
P=1.5W. No high
temperature, no hazard.
temperature, no hazard.
Pass
3.
D510
SC
264
10 min.
F501
0.124
P=10.5W max. No high
temperature, no hazard.
temperature, no hazard.
Pass
4.
D512
SC
264
10 min.
F501
0.160
P=13.4W max. No high
temperature, no hazard.
temperature, no hazard.
Pass
5.
D513 SC
264
10 min.
F501
0.142
P=12.0W. No high
temperature, no hazard.
temperature, no hazard.
Pass
6.
D514
SC
264
10 min.
F501
0.162
P=13.2W. No high
temperature, no hazard.
temperature, no hazard.
Pass
7.
EC506
SC
264
10 min.
F501
0.188
P=17.5W max. No high
temperature, no hazard.
temperature, no hazard.
Pass