DOWNLOAD Harman Kardon HS 200 (serv.man5) Service Manual ↓ Size: 5.42 MB | Pages: 66 in PDF or view online for FREE

Model
HS 200 (serv.man5)
Pages
66
Size
5.42 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-200-sm5.pdf
Date

Harman Kardon HS 200 (serv.man5) EMC - CB Certificate ▷ View online

 
                                                                  Page 26 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
         
 N/A 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
         
 N/A 
 
IT: user instructions in Italian language including a 
conformity declaration 
         
 N/A 
 
IT: certification number on the back cover 
         
 N/A 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
No such switch used. 
N/A 
 
 
Amendment 1 to EN60065, 7th edition 
 
5.4.1 
A warning that batteries (battery pack or batteries 
installed) shall not be exposed to excessive heat 
such as sunshine, fire or the like. 
 N/A 
 
Special stability warning for the apparatus with 
CRT 
Warning: the CRT in this product employs a 
protective film on the face. This film must not be 
removed as it serves a safety function and removal 
will increase the risk of serious injury. 
 N/A 
8.7 Void 
 
N/A 
8.8 
For requirements for non-separable thin sheet 
insulation in two or more layers, see 8.22. 
 N/A 
8.22 
Requirements for non-separable thin sheet 
insulation in two or more layers 
 N/A 
15.2 
Delete the paragraph:  In supply apparatus of 
Class I with non-hazardous live output voltage: 
output circuit shall not be connected to the 
protective earthing conductor. 
 N/A 
18.1 
Protective film as part of the implosion protection 
system:  all edges covered by the enclosure of the 
apparatus 
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability. 
 N/A 
20.1 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 Pass 
 
b) Exemption for small components as defined in 
20.1 excluding metal, glass and ceramic. 
 Pass 
 
                                                                  Page 27 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
5.1 
TABLE: rated current/power consumption 
Pass 
 
Model  
Input voltage 
(V) 
Rated 
current 
(mA) 
Measured 
current 
(mA) 
Rated 
power (W) 
Measured 
power (W) 
condition/status 
240  - 
366 300 43.0 
HS 200 
100  - 
720 300 41.5 
Normal DVD playing 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
7.1 
TABLE: temperature rise measurements  
Pass 
 
Power consumption in the OFF/Stand-by 
0W/2.1W max. 
— 
 
Position of the functional switch (W) ...................... :
On 
— 
 
Room temperature t1 (°C)  ...................................:
20.0 
 
 
Room temperature t2 (°C)  ...................................:
20.0 
 
 
Operating conditions 
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours 
until steady condition reached. Ambient 20
o
C. 
Un (V) 
In (mA)  
Pn (W)  
Pout (V / mA) 
264 347 
43.6 
N.A. 
90 785 
41.5 
N.A. 
 
         
 
Loudspeaker impedance (Ω) ................................. : 6Ω X 2 
— 
         
 
Several loudspeaker systems 
2 channel speakers 
Pass 
         
 
Marking of loudspeaker terminals 
Printed on rear enclosure 
Pass 
dT (K) 
monitored point: 
264 
90 
Permitted dT (K) 
Power cord 
25.1
 
27.4
 
60  
Connector  
25.9
 
27.7
 
PCB near RZ503 
36.8
 
53.3
 
85 
CY502 (Y1 capacitor)  
23.3
 
23.5
 
60 (85-25) 
CX502 (X2 capacitor ) 
29.6
 
30.5
 
60 (85-25) 
 
                                                                  Page 28 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Operating conditions 
CX503 (X2 capacitor ) 
30.6
 
30.4
 
60 (85-25) 
Winding of LF502 
31.3
 
34.5
 
75* 
PCB near BD501 
30.7
 
30.7
 
85 
PCB near Q509 
35.4
 
29.7
 
85 
PCB near U503 
34.7
 
29.7
 
85 
EC502 (electrolytic capacitor) 
32.0
 
29.6
 
80 (105-25) 
Winding of T502 
44.3
 
37.9
 
75* 
Bobbin of T502 
40.3
 
35.7
 
-- 
PCB near T502 
39.4
 
34.7
 
85 
CY504 (Y1 capacitor)  
35.1
 
32.0
 
60 (85-25) 
Winding of T503 
43.3
 
37.1
 
75* 
Bobbin of T503 
40.4
 
35.1
 
-- 
PCB near T503 
37.9
 
33.4
 
85 
CY503 (Y1 capacitor)  
35.8
 
31.9
 
60 (85-25) 
PCB near D515 
39.1
 
33.7
 
85 
EC518 (electrolytic capacitor) 
37.9
 
32.3
 
80 (105-25) 
PCB of amplifier board 
43.7
 
42.7
 
85 
PCB of main board 
36.9
 
36.0
 
85 
Enclosure (metallic)  
15.5
 
14.7
 
40  
Enclosure (non-metallic) 
7.3
 
7.0
 
60 
 
winding temperature rise measurements: 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) 
dT (K) 
required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
100 
Between parts separated by basic or supplementary insulation 
100 
 
                                                                  Page 29 of 63                            Report No. SH09051259-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between parts separated by double or reinforced insulation 
4.3 
Between parts of T502 separated by basic or supplementary 
insulation 
100 2 
Between parts of T503 separated by basic or supplementary 
insulation 
100 2 
 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
2120Vp 
No 
Between parts separated by basic or supplementary insulation 
2120Vp 
No 
Between parts separated by double or reinforced insulation 
4240Vp 
No 
Between parts of T502 separated by basic or supplementary 
insulation 
2542Vp No 
Between parts of T503 separated by basic or supplementary 
insulation 
2586Vp No 
 
11.2 
TABLE: summary of fault condition tests 
Pass 
         
  Model/type of power supply  .................................: -- 
— 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. : 100-240 
 
         
  Ambient temperature (
o
C) ...................................... : 24 
— 
 
No. 
Component 
No. 
Fault 
Test 
voltage 
(V) 
Test 
time 
Fuse 
No. 
Fuse 
current
(A) 
Result 
Dielectric 
strength 
test after 
the test
1.  
U502: 
secondary     
  
SC 264 
10 
min.
F501
0.063 
P=1.7W. No high 
temperature, no hazard.  
Pass 
2.   
R531          SC 
264 
10 min.
F501
0.062 
P=1.5W. No high 
temperature, no hazard.  
Pass 
3.   
D510      
SC 
264 
10 min.
F501
0.124 
P=10.5W max. No high 
temperature, no hazard.  
Pass 
4.   
D512      
SC 
264 
10 min.
F501
0.160 
P=13.4W max. No high 
temperature, no hazard.  
Pass 
5.   
D513          SC 
264 
10 min.
F501
0.142 
P=12.0W. No high 
temperature, no hazard.  
Pass 
6.   
D514      
SC 
264 
10 min.
F501
0.162 
P=13.2W. No high 
temperature, no hazard.  
Pass 
7.   
EC506   
SC 
264 
10 min.
F501
0.188 
P=17.5W max. No high 
temperature, no hazard.  
Pass 
Page of 66
Display