DOWNLOAD Harman Kardon HKTS 210SUB (serv.man5) Service Manual ↓ Size: 876 KB | Pages: 17 in PDF or view online for FREE

Model
HKTS 210SUB (serv.man5)
Pages
17
Size
876 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-210sub-sm5.pdf
Date

Harman Kardon HKTS 210SUB (serv.man5) EMC - CB Certificate ▷ View online

Test report no. 1018989I
Page 9 (14)
Photos of the EUT showing the location of the selected test points.
Test points (1) and (2)
Test report no. 1018989I
Page 10 (14)
7.4 Measurement uncertainty
The uncertainty of the applied electrostatic discharges is within the tolerance specified by the
standard.
7.5 Test equipment
Equipment
Manufacturer
Type
Inv. No.
ESD-generator:
Schaffner
NSG 435 ESD simulator 5854
AF oscillator
Chung Instruments 555
5211
Reference ground plane
Aluminium: 3,5 m x 3,0 m x 1,5 mm
Horizontal coupling plane
Aluminium: 1,6 m x 0,8 m x 1,5 mm
Vertical coupling plane
Aluminium: 0,5m x 0,5 m x 1,5 mm
7.6 Test protocol
Date of test: 10 August, 2010
Test point
#
Test level
[kV]
Air/
Contact
Polarity
(+/-)
Pass/
Fail
Comment
2
Contact
+/-
Pass
-
HCP 1-4
4
Contact
+/-
Pass
-
2
Contact
+/-
Pass
-
VCP 1-4
4
Contact
+/-
Pass
-
2
Contact
+/-
Pass
-
1
4
Contact
+/-
Pass
-
2
Air
+/-
Pass
-
4
Air
+/-
Pass
-
2
8
Air
+/-
Pass
-
Test report no. 1018989I
Page 11 (14)
8.
IMMUNITY TO RADIATED ELECTROMAGNETIC FIELD, KEYED CARRIER
8.1 Operating environment
The test was performed in a semi-anechoic shielded chamber.
Temperature:
24
C
Relative Humidity:
51 %
8.2 Test set-up
The EUT was placed on a non-metallic table 0,8 m above the reference ground plane and was
operated according to its specified operating mode.
Ferrite tiles/absorbers were placed on the RGP between the EUT and the antenna to reduce the
reflections from the RGP. The cables were exposed for the electromagnetic field for 1 m vertically
and 1 m horizontally.
Photos of the test set-up.
Test report no. 1018989I
Page 12 (14)
8.3 Generation of the electromagnetic field
The electromagnetic field is generated from a computer controlled signal generator. The output
power is amplified and then radiated from broad band log periodic antennas. For each sweep a
pre-recorded empty chamber calibration file is used to establish the required field strength. When
using these files the field strength inside an area of 1,5 m x 1,5 m is in accordance with the
standard.
8.4 Test conditions
Test level:
3 V/m, 1/8 duty cycle, 217 Hz rep. frequency
Frequency range:
895 MHz - 905 MHz
Performance criterion:
A
Frequency step:
5 MHz
Dwell time at each frequency:
15 s
Field orientation:
Vertical
Antenna distances:
3 m
Exposed sides:
Left and right (The front side of the EUT is positioned parallel to
the antenna line of sight.)
Operating mode:
42 Hz sinus signal
8.5 Measurement uncertainty
The measurement uncertainty is: ± 0,82 V/m.
Measurement uncertainty is calculated in accordance with EA-4 /02:1997. The measurement
uncertainty is given with a confidence of 95%. The uncertainty calculations exclude influence of
phenomena like inhomogenity of the electric field intensity.
Page of 17
Display

Click on the first or last page to see other HKTS 210SUB (serv.man5) service manuals if exist.