Test report no. 1018989I
Page 13 (14)
8.6 Test equipment
Equipment
Manufacturer
Type
Inv. No.
Test site:
Semi-anechoic shielded chamber
12690
Software
RSUS
RSUS, Version 2.134
Signal generator:
Rohde & Schwarz
SMY 01
7831
Waveform Generator:
Hewlett Packard
33120A
5863
RF Power Meter:
Rohde & Schwarz
NRVD
7860
Amplifier 80 - 1000 MHz:
Amplifier Research 200 W1000M7A
12458
Transmitting antenna
30 - 1000 MHz:
CHASE
CBL6111B
12474
AF oscillator
Chung Instruments 555
5211
8.7 Test protocol
Date of test: 6 August, 2010
Test
No.
Freq.
[MHz]
Level
[V/m]
Pol.
V/H
Exposed side
Pass/
Fail
Comment
1
895-905
3
V
Left
Pass
-
2
895-905
3
V
Right
Pass
-
Test report no. 1018989I
Page 14 (14)
9.
IMMUNITY TO ELECTRICAL FAST TRANSIENTS, BURST
9.1 Operating environment
Temperature:
20
C
Relative Humidity:
70 %
9.2 Test set-up
The EUT was placed on a non-metallic distance 0,1 m above a reference ground plane (RGP)
and was put into operation according to the specified operating mode.
and was put into operation according to the specified operating mode.
9.3 Test conditions
Test level:
+/- 1,0 kV
Performance criterion:
B
Repetition rate:
5 kHz
Application method:
AC mains - Coupling/decoupling network, (CDN)
Duration of each test:
2 min
Operating mode:
42 Hz sinus signal
9.4 Measurement uncertainty
The uncertainty of the applied fast transient/burst is within the tolerance specified by the
standard.
standard.
9.5 Test equipment
Equipment
Manufacturer
Type
Inv. No.
Test generator including CDN: EM test
EFT500
7490
AF oscillator
Chung Instruments 555
5211
Reference ground plane
Aluminium 3,5 m x 3,0 m x 1,5 mm
9.6 Test protocol
Date of test: 9 August, 2010
Test
No.
Level
[kV]
Polarity
+/-
Line/Cable
Coupling
Device
Pass/
Fail
Comment
1
1
+
AC-power (L/N)
CDN
Pass
-
2
1
-
AC-power (L/N)
CDN
Pass
-
Test report no.1018989I
Appendix S2a Page 1 (2)
Test:
Immunity Conducted Voltages S2a <1018989 Meiloon>
Test Mode:
Amplifier -
Monitor:
Speaker
Operating Mode:
Audio input L/R
S/N:
77.8 dB
Frequency:
-
AF Level:
51.7 mW
Interf. Signal: Input L/R, 100810 -00005-001, 2010 -08-10, 12:00:15
80/70
70/80
60/90
50/100
40/110
30/120
20/130
10/140
0/150
S/N
[dB]
//
Level
(E.M.F.)
[dBµV]
150k
400k
1M
2M
3M
5M 7M 10M
20M30M 50M
150M
Frequency
[Hz]
Test report no.1018989I
Appendix S2a Page 2 (2)
Test:
Immunity Conducted Voltages S2a <1018989 Meiloon>
Test Mode:
Amplifier -
Monitor:
Speaker
Operating Mode:
Audio input L/R
S/N:
77.8 dB
Frequency:
-
AF Level:
51.7 mW
Interf. Signal: Mains, 100810 -00005-002, 2010-08-10, 12:07:12
80/70
70/80
60/90
50/100
40/110
30/120
20/130
10/140
0/150
S/N
[dB]
//
Level
(E.M.F.)
[dBµV]
150k
400k
1M
2M
3M
5M 7M 10M
20M30M 50M
150M
Frequency