Test report no. 1018989I
Page 5 (14)
5.
PERFORMANCE CRITERIA
5.1 Performance criteria
The performance criteria are based on the general criteria in the standard.
Performance criteria
Criterion A:
The equipment shall continue to operate as intended during the test. No change
of actual operating state (see below) is allowed as a result of the application of
the test.
Criterion B:
The equipment shall continue to operate as intended after the test. No loss of
function is allowed after the test when the apparatus is used as intended. No
change of actual operating state (see below) is allowed as a result of the
application of the test. During the test, degradation of performance is allowed.
Change of actual operating state of the EUT:
The EUT stops amplify the signal from the generator.
The criterion concerning acceptable sound interference is a wanted to unwanted audio signal
ratio of
40 dB at a wanted audio signal level of 50 mW.
5.2 Performance verification
The test engineer observed the performance of the EUT directly or via video cameras.
The audio output power was checked via software T80-K1 and speakers connected to the EUT
respectively.
The audio output was checked via a microphone connected to a measuring amplifier.
Test report no. 1018989I
Page 6 (14)
6.
TEST PROCEDURES
6.1 Input immunity (S1)
This test is applicable only for equipment with a connection facility for an external antenna.
6.2 Induced voltages (S2a)
During the measurement of immunity to induced voltages the EUT was placed 0,1 m above a
metallic ground plane of dimensions 2 x 1 m.
The wanted signal was fed to all relevant input terminals respectively and the unwanted signal
was fed to mains input, audio output and input terminals respectively.
Performance criterion: A
6.3 RF voltages in common mode (S2b)
This test is applicable only for equipment with a connection facility for an external antenna.
6.4 Radiated fields, AM modulated carrier (S3)
The EUT was placed 0,1 m above a non-metallic support, in the centre of the stripline.
The wanted signal was fed to all input terminals respectively. The unwanted signal was fed to a
matching network at the feeding point of the stripline.
Performance criterion: A
6.5 Screening effectiveness (S4)
This test is applicable only for equipment with a connection facility for an external antenna.
Test report no. 1018989I
Page 7 (14)
6.6 Electrostatic discharge
See chapter 7.
6.7 Radiated electromagnetic fields, keyed carrier
See chapter 8.
6.8 Electrical fast transients, burst
See chapter 9.
6.9 Measurement uncertainty
The measurement uncertainty for S1 is: ± 1,2 dB.
The measurement uncertainty for S2 is: ± 2,1 dB.
The measurement uncertainty for S3 is: ± 2,1dB.
The measurement uncertainty for S4 is: ± 3,3 dB.
Measurement uncertainty is calculated in accordance with EA-4 /02:1997. The measurement
uncertainty is given with a confidence of 95%. The uncertainty calculations exclude influence of
phenomena like inhomogenity of the electric field intensity.
6.10 Test equipment
Equipment
Manufacturer
Type
Inv. No.
Software
Rohde & Schwarz
T80-K1, version 2.21
Signal generator
Rohde & Schwarz
SMH
3564
Power meter
Rohde & Schwarz
NRVD
7475
100-V Insertion unit
Rohde & Schwarz
URV5-Z4
12611
Audio analyzer
Rohde & Schwarz
UPL
12601
Power amplifier
Bonn
BSA1515-25
12606
Strip line cell
361
Matching network
Erika Fiedler
MN 50-150
Ω
30364
Termination
Erika Fiedler
TI 150
Ω
30365
Test report no. 1018989I
Page 8 (14)
7.
IMMUNITY TO ELECTROSTATIC DISCHARGE
7.1 Operating environment
Temperature:
23
C
Relative Humidity:
56 %
7.2 Test set-up
A horizontal coupling plane (HCP) was placed on a non-metallic table 0,8 m above a reference
ground plane (RGP) and connected to it with a cable with two 470 k
resistors. The EUT was
placed on an insulation sheet on the HCP and was operating according to the specified operating
mode.
A vertical coupling plane (VCP) was connected to the RGP with a cable with two 470 k
resistors.
7.3 Test conditions
Test level:
+/- 2, 4 kV Contact discharge
+/- 2, 4, 8 kV Air discharge
Number of discharges at each point:
10 of each polarity
Performance criterion:
B
Operating mode:
42 Hz sinus signal.
The selected test points are listed in this table, the numbers refer to the photos on the next page.
Point
Description
VCP 1 0,1 m from the front of the EUT
VCP 2 0,1 m from the back of the EUT
VCP 3 0,1 from the right of the EUT
VCP 4 0,1 from the left side of the EUT
HCP 1 0,1 m from the front of the EUT
HCP 2 0,1 m from the back of the EUT
HCP 3 0,1 from the right of the EUT
HCP 4 0,1 from the left side of the EUT
1
Control panel in metal, screws and inlet within reachable
metal LINE LEVEL IN
2
Cover all sides, signal LED, all knobs and button without
reachable metal, inlet EXT.Trigger input
Contact discharges were applied to the VCP and the HCP.