Harman Kardon HKTS 210SUB (serv.man2) EMC - CB Certificate ▷ View online
Page 7 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
5
C3
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.36A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 47mA U
out
= 0V
U
n
= 198V, P
n
= 0.5W, I
n
= 35mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
6
U2
Short circuit
On the
secondary
side.
On the
secondary
side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.44A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 48mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 38mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
7 U2
Short
circuit
On the
primary side.
primary side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.4W, I
n
= 45mA U
out
= 0V
U
n
= 198V, P
n
= 0.3W, I
n
= 34mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
8 U2
Disconnect
device on
primary side.
device on
primary side.
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.43A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 49mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 38mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
Page 8 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
9
C22
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 2.8W, I
n
= 53mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 52mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
10
R38
Short circuit T2 = 16K
DT1 = 30K
U1 = 65K
CT1 = 36K
Other temperature
no higher
U1 = 65K
CT1 = 36K
Other temperature
no higher
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 7.3W, I
n
= 76mA U
out
= 0V
The test went on for 2 hours.
11
R38
Short circuit T2 = 16K
DT1 = 24K
U1 = 66K
CT1 = 37K
Other temperature
no higher
U1 = 66K
CT1 = 37K
Other temperature
no higher
U
n
= 198V, P
n
= 44W, I
n
= 0.46A U
out
= 10.8V
Immediately after fault condition
U
n
= 198V, P
n
= 6.8W, I
n
= 83mA U
out
= 0V
The test went on for 2 hours and 10 minutes.
12 BR1
Short
circuit
-
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.41A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 0V, P
n
= 0W, I
n
= 0A U
out
= 0V
U
n
= 0V, P
n
= 0W, I
n
= 0A U
out
= 0V
Fuse activated immediately
13
C1 near U1
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
The test went on for 5 more minutes.
No remarks
Page 9 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
14 U1
(SG3525AP)
Short circuit
Vc – GND
Vc – GND
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
The test went on for 5 more minutes.
No remarks
15 U1
(ICE3B0365J)
Short circuit
Vc – GND
Vc – GND
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 46mA U
out
= 0V
U
n
= 198V, P
n
= 0.5W, I
n
= 34mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
16 U1
(ICE3B0365J)
Short circuit
Vc – D
Vc – D
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.34A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
Fuse activated immediately.
17
IC1
Short circuit
pin Vcc – InLA
PWB 34K
IC 19K
Other temperature
no higher
IC 19K
Other temperature
no higher
U
n
= 264V, P
n
= 45W, I
n
= 0.38A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 36W, I
n
= 0.34A U
out
= 6.0V
The test went on for 20 more minutes.
18
C21
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.35A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 3.0W, I
n
= 66mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
Page 10 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
19 CN2
Short
circuit
Pin 1 – 2
(U
(U
speaker
)
No heat
development
development
U
n
= 264V, P
n
= 45W, I
n
= 0.4A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 2.4W, I
n
= 62mA
U
out
Declined for 45 seconds and then damage
components in PSU.
No remark
No remark
* 20
U1
(ICE3B0365J)
(ICE3B0365J)
Short circuit
pin 2 – 5
pin 2 – 5
No heat
development
development
U
n
= 264V
Apparatus shut down immediately.
Test time 10 min.
U
Test time 10 min.
U
n
= 264V, P
n
= 0.5 W, I
n
= 114mA U
out
= 0V
Damage components no hazard.
Dielectric strength test 3kV / 1 min. on
optocoupler U2. / OK
No remark
Dielectric strength test 3kV / 1 min. on
optocoupler U2. / OK
No remark
Winding temperature rise measurements
Ambient temperature t1 (
o
C) .................................. : -
—
Ambient temperature t2 (
o
C) .................................. : -
—
* New fault condition No. 20: U1 Short circuit pin 2 – 5.
Click on the first or last page to see other HKTS 210SUB (serv.man2) service manuals if exist.