Harman Kardon HKTS 210SUB (serv.man2) EMC - CB Certificate ▷ View online
Page 3 of 12
Report No.:1112717
TRF No. IEC60065J
Summary of testing:
Tests performed (name of test and test clause):
See r
elevant part of the
IEC 60065 Test report
Testing location:
See page 2
Summary of compliance with National Differences:
National differences for Singapore.
Copy of marking plate
Page 4 of 12 Report No.:1112717
TEST REPORT issued by an Accredited Testing Laboratory. Accredited by Swedac, no 1003, ISO/IEC 17025
Test item particulars:
Classification of installation and use........................: Class II
Supply connection ....................................................: Mains plug
...................................................................................:
...................................................................................:
Possible test case verdicts:
- test case does not apply to the test object.............: N/A (Not applicable)
- test object does meet the requirement...................: P
(Pass)
- test object does not meet the requirement.............: F
(Fail)
Testing.:
Date of receipt of test items ......................................: 1 April 2011
Date(s) of performance of tests ................................: 1
–
8 April 2011
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (comma) is used as the decimal separator.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (comma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
Factory:
Dongguan Meiloon Acoustic Equipments Co., Ltd
No. 77 Yuan Lin Road, Feng Huang Industrial Zone
No. 77 Yuan Lin Road, Feng Huang Industrial Zone
Tangxia, Dongguan City
Guangdong Province 523727, CHINA
Note: The Zenerdiode (TVS) is for protection of optocoupler U2.
Page 5 of 12
Report No.1112717
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N/A
10.2
Humidity treatment 48 h or 120 h ...........................: 120
h
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 10
Min. 2
Between parts separated by basic or supplementary insulation
-
-
* Between parts separated by double or reinforced insulation
>10
Min. 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120
No
Between parts separated by basic or supplementary insulation
-
-
* Between parts separated by double or reinforced insulation
4240
No
* This test includes dielectric strength test 3kV / 1 min. on optocoupler U2.
Page 6 of 12
Report No.1112717
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. 220-240
—
Frequency
(Hz)........................................................ 50/60
—
Ambient
temperature
(
o
C) ...................................... 26 – 27
—
No
Component
Fault
dT (K) / Component Other results
(include description and test duration)
1
Apparatus
Maximum no
clip output
power
clip output
power
Transf. T2 = 67K
Transf. T1 = 51K
Heatsink HS2 = 50K
Other temperature
no higher
Transf. T1 = 51K
Heatsink HS2 = 50K
Other temperature
no higher
U
n
= 264V, P
n
= 60W, I
n
= 0.58A U
out
= 18V
After 3.5 hours temperature stabilized
U
U
n
= 264V, P
n
= 58W, I
n
= 0.57A U
out
= 18V
2
C6
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.42A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.7W, I
n
= 47mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
3
C6
Short circuit No heat
development
U
n
= 198V, P
n
= 44W, I
n
= 0.48A U
out
= 10.8V
Immediately after fault condition
U
n
= 198V, P
n
= 0.6W, I
n
= 36mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
4
C26
Short circuit No heat
development
U
n
= 264V, P
n
= 45W, I
n
= 0.36A U
out
= 10.8V
U
n
= 198V, P
n
= 44W, I
n
= 0.45A U
out
= 10.8V
Immediately after fault condition
U
n
= 264V, P
n
= 0.8W, I
n
= 48mA U
out
= 0V
U
n
= 198V, P
n
= 0.6W, I
n
= 37mA U
out
= 0V
Went immediately in to protection mode and
the test went on for 5 more minutes.
Click on the first or last page to see other HKTS 210SUB (serv.man2) service manuals if exist.