Page 3 of 12 
 
Report No.:1112717
  
 
TRF No. IEC60065J 
 
Summary of testing: 
Tests performed (name of test and test clause): 
See r
elevant part of the 
IEC 60065 Test report 
Testing location:  
See page 2 
Summary of compliance with National Differences: 
National differences for Singapore. 
Copy of marking plate 
 
                                                                            Page 4 of 12                                               Report No.:1112717 
 
TEST REPORT issued by an Accredited Testing Laboratory. Accredited by Swedac, no 1003, ISO/IEC 17025
 
 
 
Test item particulars: 
 
Classification of  installation and use........................:  Class II 
Supply connection ....................................................: Mains plug 
...................................................................................:  
...................................................................................:  
Possible test case verdicts: 
 
- test case does not apply to the test object.............:  N/A (Not applicable) 
- test object does meet the requirement...................: P 
(Pass) 
- test object does not meet the requirement.............: F 
(Fail) 
Testing.: 
 
Date of receipt of test items ......................................:  1 April 2011 
Date(s) of performance of tests ................................: 1 
– 
8 April 2011 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report, a point (comma) is used as the decimal separator. 
List of test equipment must be kept on file and available for review. 
General product information: 
Factory:  
             Dongguan Meiloon Acoustic Equipments Co., Ltd 
             No. 77 Yuan Lin Road, Feng Huang Industrial Zone 
 
Tangxia, Dongguan City 
 
Guangdong Province 523727, CHINA  
 
Note: The Zenerdiode (TVS) is for protection of optocoupler U2. 
 
Page 5 of 12 
 
Report No.1112717 
  
IEC60065  
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation .................................................................: 
 N/A 
10.2 
Humidity treatment 48 h or 120 h  ...........................: 120 
10.3 
Insulation resistance and dielectric strength 
between mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1)  
 N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table 10.3) 
 
10.3 
TABLE: insulation resistance measurements 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected)  
> 10 
Min. 2 
Between parts separated by basic or supplementary insulation 
* Between parts separated by double or reinforced insulation  
>10 
Min. 4 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected)  
2120 
No 
Between parts separated by basic or supplementary insulation 
* Between parts separated by double or reinforced insulation 
4240 
No 
 
This test includes dielectric strength test 3kV / 1 min. on optocoupler U2.
Page 6 of 12 
 
Report No.1112717 
  
IEC60065 - ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. 220-240 
— 
 Frequency 
(Hz)........................................................ 50/60 
— 
 Ambient 
temperature 
(
o
C) ...................................... 26 – 27 
— 
 
No 
Component 
Fault 
dT (K) / Component  Other results 
(include description and test duration) 
Apparatus  
Maximum no 
clip output 
power  
Transf. T2 = 67K 
Transf. T1 = 51K 
Heatsink HS2 = 50K 
Other temperature 
no higher 
U
n
 = 264V, P
n
 = 60W, I
n
 = 0.58A U
out
 = 18V 
After 3.5 hours temperature stabilized  
U
n
 = 264V, P
n
 = 58W, I
n
 = 0.57A U
out
 = 18V 
C6 
Short circuit  No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.42A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 0.7W, I
n
 = 47mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes.  
C6 
Short circuit  No heat 
development 
U
n
 = 198V, P
n
 = 44W, I
n
 = 0.48A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 198V, P
n
 = 0.6W, I
n
 = 36mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes.  
C26 
Short circuit  No heat 
development 
U
n
 = 264V, P
n
 = 45W, I
n
 = 0.36A U
out
 = 10.8V 
U
n
 = 198V, P
n
 = 44W, I
n
 = 0.45A U
out
 = 10.8V 
 
Immediately after fault condition 
U
n
 = 264V, P
n
 = 0.8W, I
n
 = 48mA U
out
 = 0V 
U
n
 = 198V, P
n
 = 0.6W, I
n
 = 37mA U
out
 = 0V 
 
Went immediately in to protection mode and 
the test went on for 5 more minutes.  