Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate ▷ View online
Page 31 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
6.1
Replace
the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Soldered joints and paint lockings are
examples of adequate locking.
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any
point 10 cm from the outer surface of the
apparatus, the dose-rate shall not exceed 1µSv/h
(0.1 Mr/h) taking account of the background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70% of the
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1.5 MHz in the centre, with a similar vertical
degradation;
- not more than over flashover per 5 min.
examples of adequate locking.
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any
point 10 cm from the outer surface of the
apparatus, the dose-rate shall not exceed 1µSv/h
(0.1 Mr/h) taking account of the background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70% of the
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1.5 MHz in the centre, with a similar vertical
degradation;
- not more than over flashover per 5 min.
N/A
13.3.1
Delete
note 4.
N/A
14
Delete
note 4 and note 5.
P
15.1.1
Delete
notes 1 and 2.
N/A
15.2
Delete
note 2.
N/A
16.1
Delete
note 1.
N/A
16.2
Delete
the note.
N/A
20
Delete
note 2.
N/A
Annex B
Replace
note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
special national conditions apply.
P
Page 32 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Annex G
Delete
the note.
N/A
Annex J.2 Delete the notes of Table J.1.
N/A
Annex N
Add
after the introduction:
For ROUTINE TEST reference is made to EN
50333.
50333.
P
Bibliography
Add
the following standards:
EN 60332-1: 2000, Sound system equipement: Headphones and earphones
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for ”one package equipment”.
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for ”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipement: Headphones and
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology
and limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers.
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology
and limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers.
Add the following notes for the standards indicated:
IEC 60130
NOTE
Parts 9 and 17: 1998 are harmonized as Ens (not modified).
IEC 60169
NOTE Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE Harmonized as HD 27 S1: 1978 (not modified).
IEC 60335-2-56 NOTE
Harmonized as EN 60335-2-56: 1997 (not modified).
IEC 60335-2-82 NOTE Harmonized as EN 60335-2-82: 2000 (not modified).
IEC 60695
IEC 60695
NOTE Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE Harmonized as EN 61040: 1992 (not modified).
IEC 61558-2-1
NOTE
Harmonized as EN 61558-2-1: 1997 (not modified).
IEC 61558-2-4
NOTE Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6
NOTE Harmonized as EN 61558-2-6: 1997 (not modified).
N/A
Page 33 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Annex ZA
Other international publications quoted in this standard with the references of the
relevant European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited
at the appropriate places in the text and the publications are listed hereafter. For dated
references, subsequent amendments to or revisions of
any of these publications apply to this European Standard only when incorporated in it by
amendment or revision. For undated references the
latest edition of the publication referred to applies (including amendments).
relevant European publications
This European Standard incorporates by dated or undated reference, provisions from other
publications. These normative references are cited
at the appropriate places in the text and the publications are listed hereafter. For dated
references, subsequent amendments to or revisions of
any of these publications apply to this European Standard only when incorporated in it by
amendment or revision. For undated references the
latest edition of the publication referred to applies (including amendments).
NOTE When an international standard has been modified by common modification, indicated by (mod), the
relevant EN/HD applies.
P
Page 34 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Annex ZA
Cont.
P
Click on the first or last page to see other HKTS 11 (serv.man13) service manuals if exist.