Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
11.2 TABLE: 
summary 
of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage ........ : 
220-230 
— 
 Frequency 
(Hz)................................................... : 
50/60 
— 
 Ambient 
temperature 
(
o
C) ................................. :  21 
— 
No 
Component 
Fault 
Temp Rise/ 
Component 
Other results 
(include description and test duration) 
Speaker out. 
 
Max 
69K/windings max 
44K/PCB, heat sink 
22K/metal enclosure
Un=253V, Pn= 120W, In= 0.6A.  
Test time= 4h. 
No high temperatures, no remarks. 
Speaker 
sc 
-- 
Un=253V, Pn= 9W, In= 0.067A. The unit shutdown.
Test time= 30min.                                                      
No high temperatures, no remarks. 
3 C501 sc 
-- 
Un=253/198V. F501 opened immediately. 
No high temperatures, no remarks. 
4 Q301 
(c-e) sc 
-- 
253V, Pn= 15W, In= 0.1A. Test time: 30 min.        
No high temperatures, no remarks. 
5 Q302 
(c-e) sc 
-- 
253V, Pn= 15W, In= 0.1A. Test time: 30 min.        
No high temperatures, no remarks.. 
Q111 (c-e) 
sc 
-- 
Un=253V, Pn= 9W, In= 0.067A. The unit shutdown.
Test time= 30min.                                                      
No high temperatures, no remarks. 
PW150D 
V+ to AGND 
sc -- 
Un=253/198V. F501 opened immediately. 
No high temperatures, no remarks. 
PW150D 
V- to AGND 
sc -- 
Un=253/198V. F501 opened immediately. 
No high temperatures, no remarks. 
 
 
Page 28 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
13 
TABLES: clearances and creepage distances 
Rated supply voltage:  220-230 V 
Pollution degree: 
II 
Material Group: 
IIIb 
2 N force on internal parts applied: 
30 N force on outside of conductive enclosure applied: 
 
 
Location 
 
Operating Voltage 
 
Clearance (mm) 
 
Creepage (mm) 
 
 
V rms 
 
V peak 
 
Min 
 
Actual 
 
Min 
 
Actual 
 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
 
Primary (ac) to Earth (B) 
 
 
 
 
 
 
 
Primary (+dc) to Earth max (B) 
 
 
 
 
 
 
 
Primary (-dc) to Earth max (B) 
 
 
 
 
 
 
 
Across mains fuse (B) 
 
230 
 
345 
 
2.0 
 
8.2 
 
2.3 
 
8.4 
Across primary directly connected to 
the mains (in the main switch)(B) 
 
230 
 
345 
 
2.0 
 
6.1 
 
2.3 
 
6.1 
 
Hazardous live secondary to Earth (B)
 
 
 
 
 
 
Optocoupler input to output (R) 
 
 
 
 
 
 
Primary to Secondary in transformer  
TT0900305570-E (R) 
 
328 
 
463 
 
4.2
 
 
>10 
 
6.9 
 
>10 
Primary to Secondary in transformer  
150-r4055904-e (R) 
 
328 
 
463 
 
4.2
 
 
>10 
 
6.9 
 
9.0 
Primary to Secondary in transformers
  
TD-230-0250K (R)
 
 
325 
 
460 
 
4.5 
 
>10 
 
6.9 
 
7.1 
Primary to accessible conductive 
parts (R) 
 
230 
 
345 
 
4.0 
 
>10 
 
4.6 
 
6.0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. 
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in 
Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed 
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the 
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an 
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth 
via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from 
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 
or 10 as required, then the value for clearance is used as the minimum creepage distance . 
 
"Min" = minimum required.
 
"Actual = Actual dimensions measured. 
 
 
Page 29 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Transformer T501 
Shanghai 
Transtec 
TT0900305570-E
50Hz  230V 
IEC 60065 
Tested in the 
appliance 
*)
Thermal cut-out 
Seki 
ST-22 
130
°C 5A 250V
IEC 60065 
— 
Xuzhou Gloria 
Electronics 
TD-230-0250K  
50Hz  230V 
IEC 60065 
Tested in the 
appliance 
Alt. Transformer T501 
 
*)
Thermal cut-out 
Seki ST-22 
130
°C 5A 250V
IEC 60065 
— 
Zhong Shan 
HuiRan 
150-r4055904-e
 
50Hz  230V 
IEC 60065 
Tested in the 
appliance 
Alt. Transformer T501 
 
Alt. thermal link 
Aupo electronics
A2 
115
°C 5A 250V
IEC 60691 
VDE 
Mains Fuse F501 
Conquer 
UTE 
T1.6AL   250V 
IEC 60127 
 
Mains fuse holder 
Bussman 
HTB-32M 
10A    250V 
(94V-0) 
Complies with 
IEC 60707      
HB75 
__ 
Mains switch SW501 
CHILY 
3024 
16(4) 8/128A, 
250V Class II 
IEC 61058-1 
IEC60065:2001
Sub-clause 
14.6 1a) 
FI 
Plug 
I Sheng 
SP-021A 
2.5A   250V 
CEE 7 
Cord 
 
H03VVH2-F 
2 x 0.75mm² 
IEC 60227 
 
X2-capacitors across 
L-N 
(EMI filter) 
Europtronic MPX  0.1µF 
and 
0.22µF 275V 
IEC 60384-14 
2
nd
 edition 
 
Heat shrinkable tube 
Shenzhen 
Changyuan 
VW-1 Min 
FV0 
Complies 
with 
IEC 60707     
HB75 
— 
Jian He 
(Cheng Ho) 
104-HKTS7A00 
104-HKTS1400 
PCB 
 
Alt. 
Hsiang Kuo 
104-LF03001 
104DS15000 
FV-0 
Complies with 
IEC 60707      
HB75 
— 
 
*) Did not open during fault condition tests 
 
 
 
 
 
 
Page 30 of 48 
Report Ref No.: 615320 
IEC 60065 
Clause 
Requirement + Test 
 
Result - Remark 
Verdict
 
 
 
 
Group differences  
IEC 60065:2001          
                                                                
CB Bulletin 110A / GRP 06  I
 
 
Contents 
Add the following annexes: 
Annex ZA (normative) Other international publications quoted in this standard 
with the references of the relevant European publications (See the CB Bulletine) 
Annex ZB (nominative) Special national conditions 
Annex ZC (informative) A-deviations  
3.1 
Add the following indent at the end of the list 
Exposure to excessive sound pressures 
from headphones or earphones 
NOTE  A new method of measurement is described in 
EN 50332-1, Sound system equipment: Headphones 
and earphones associated 
with portable audio equipment – Maximum sound 
pressure level measurement methodology and limit 
considerations – Part 1: General 
method for ”one package equipment”, and in EN 
50332-2, Sound system equipment: Headphones and 
earphones associated with 
portable audio equipment – Maximum sound pressure 
level measurement methodology and limit 
considerations – Part 2: Guidelines to 
associate sets with headphones coming from different 
manufacturers. 
 N/A 
4.1.1 
Replace 
the text of the note by: 
NOTE For ROUTINE TEST reference is made to EN 
50333
 P 
5.1.i) 
Add 
the following note: 
NOTE For RATED POWER CONSUMPTION 
mesurements of TVs reference is made to EN 60107. 
 N/A 