Harman Kardon HKTS 11 (serv.man13) EMC - CB Certificate ▷ View online
Page 27 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
11.2 TABLE:
summary
of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ........ :
220-230
—
Frequency
(Hz)................................................... :
50/60
—
Ambient
temperature
(
o
C) ................................. : 21
—
No
Component
Fault
Temp Rise/
Component
Component
Other results
(include description and test duration)
(include description and test duration)
1
Speaker out.
Max
69K/windings max
44K/PCB, heat sink
22K/metal enclosure
Un=253V, Pn= 120W, In= 0.6A.
Test time= 4h.
No high temperatures, no remarks.
2
Speaker
sc
--
Un=253V, Pn= 9W, In= 0.067A. The unit shutdown.
Test time= 30min.
No high temperatures, no remarks.
3 C501 sc
--
Un=253/198V. F501 opened immediately.
No high temperatures, no remarks.
4 Q301
(c-e) sc
--
253V, Pn= 15W, In= 0.1A. Test time: 30 min.
No high temperatures, no remarks.
5 Q302
(c-e) sc
--
253V, Pn= 15W, In= 0.1A. Test time: 30 min.
No high temperatures, no remarks..
6
Q111 (c-e)
sc
--
Un=253V, Pn= 9W, In= 0.067A. The unit shutdown.
Test time= 30min.
No high temperatures, no remarks.
7
PW150D
V+ to AGND
sc --
Un=253/198V. F501 opened immediately.
No high temperatures, no remarks.
8
PW150D
V- to AGND
sc --
Un=253/198V. F501 opened immediately.
No high temperatures, no remarks.
Page 28 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
13
TABLES: clearances and creepage distances
P
Rated supply voltage: 220-230 V
Pollution degree:
II
Material Group:
IIIb
2 N force on internal parts applied:
P
30 N force on outside of conductive enclosure applied:
P
Location
Operating Voltage
Clearance (mm)
Creepage (mm)
V rms
V peak
Min
Actual
Min
Actual
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
Primary (ac) to Earth (B)
-
-
-
-
-
-
Primary (+dc) to Earth max (B)
-
-
-
-
-
-
Primary (-dc) to Earth max (B)
-
-
-
-
-
-
Across mains fuse (B)
230
345
2.0
8.2
2.3
8.4
Across primary directly connected to
the mains (in the main switch)(B)
the mains (in the main switch)(B)
230
345
2.0
6.1
2.3
6.1
Hazardous live secondary to Earth (B)
-
-
-
-
-
-
Optocoupler input to output (R)
-
-
-
-
-
-
Primary to Secondary in transformer
TT0900305570-E (R)
TT0900305570-E (R)
328
463
4.2
>10
6.9
>10
Primary to Secondary in transformer
150-r4055904-e (R)
150-r4055904-e (R)
328
463
4.2
>10
6.9
9.0
Primary to Secondary in transformers
TD-230-0250K (R)
325
460
4.5
>10
6.9
7.1
Primary to accessible conductive
parts (R)
parts (R)
230
345
4.0
>10
4.6
6.0
Notes:
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g.
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in
Tables 8 and 9.
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth
via a component such as a capacitor.
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9
or 10 as required, then the value for clearance is used as the minimum creepage distance .
"Min" = minimum required.
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g.
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in
Tables 8 and 9.
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed
(e.g. antenna signal input), are subjected to the requirements for circuits conductively connected to the
mains in Tables 8 and 9 unless the floating secondary circuit is separated from the primary circuits by an
earthed metal screen (e.g. in the power transformer), or the floating secondary circuit is connected to earth
via a component such as a capacitor.
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from
secondary circuits to earth, see Cl. 4.3.1, 4.3.2 and 11.2.
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9
or 10 as required, then the value for clearance is used as the minimum creepage distance .
"Min" = minimum required.
"Actual = Actual dimensions measured.
Page 29 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
14
TABLE: list of critical components and materials
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Transformer T501
Shanghai
Transtec
TT0900305570-E
50Hz 230V
IEC 60065
Tested in the
appliance
*)
Thermal cut-out
Seki
ST-22
130
°C 5A 250V
IEC 60065
—
Xuzhou Gloria
Electronics
TD-230-0250K
50Hz 230V
IEC 60065
Tested in the
appliance
Alt. Transformer T501
*)
Thermal cut-out
Seki ST-22
130
°C 5A 250V
IEC 60065
—
Zhong Shan
HuiRan
150-r4055904-e
50Hz 230V
IEC 60065
Tested in the
appliance
Alt. Transformer T501
Alt. thermal link
Aupo electronics
A2
115
°C 5A 250V
IEC 60691
VDE
Mains Fuse F501
Conquer
UTE
T1.6AL 250V
IEC 60127
Mains fuse holder
Bussman
HTB-32M
10A 250V
(94V-0)
Complies with
IEC 60707
HB75
__
Mains switch SW501
CHILY
3024
16(4) 8/128A,
250V Class II
IEC 61058-1
IEC60065:2001
Sub-clause
14.6 1a)
FI
Plug
I Sheng
SP-021A
2.5A 250V
CEE 7
Cord
H03VVH2-F
2 x 0.75mm²
IEC 60227
X2-capacitors across
L-N
(EMI filter)
Europtronic MPX 0.1µF
and
0.22µF 275V
IEC 60384-14
2
nd
edition
Heat shrinkable tube
Shenzhen
Changyuan
VW-1 Min
FV0
Complies
with
IEC 60707
HB75
—
Jian He
(Cheng Ho)
104-HKTS7A00
104-HKTS1400
PCB
Alt.
Hsiang Kuo
104-LF03001
104DS15000
FV-0
Complies with
IEC 60707
HB75
—
*) Did not open during fault condition tests
Page 30 of 48
Report Ref No.: 615320
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
Group differences
IEC 60065:2001
CB Bulletin 110A / GRP 06 I
Contents
Add the following annexes:
Annex ZA (normative) Other international publications quoted in this standard
with the references of the relevant European publications (See the CB Bulletine)
with the references of the relevant European publications (See the CB Bulletine)
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
P
3.1
Add the following indent at the end of the list
-
Exposure to excessive sound pressures
from headphones or earphones
from headphones or earphones
NOTE A new method of measurement is described in
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
EN 50332-1, Sound system equipment: Headphones
and earphones associated
with portable audio equipment – Maximum sound
pressure level measurement methodology and limit
considerations – Part 1: General
method for ”one package equipment”, and in EN
50332-2, Sound system equipment: Headphones and
earphones associated with
portable audio equipment – Maximum sound pressure
level measurement methodology and limit
considerations – Part 2: Guidelines to
associate sets with headphones coming from different
manufacturers.
N/A
4.1.1
Replace
the text of the note by:
NOTE For ROUTINE TEST reference is made to EN
50333
50333
.
P
5.1.i)
Add
the following note:
NOTE For RATED POWER CONSUMPTION
mesurements of TVs reference is made to EN 60107.
mesurements of TVs reference is made to EN 60107.
N/A
Click on the first or last page to see other HKTS 11 (serv.man13) service manuals if exist.