Harman Kardon HK 970 (serv.man14) EMC - CB Certificate ▷ View online
INTERTEK TESTING SERVICES
6 of 19
Applicant: Harman Consumer Group
Report No.: 04173782
Model: HK 970
Worst Case Operating Mode: Amplifying
Worst Case Operating Mode: Amplifying
EN55013
RFI Voltage Test
Used Test Equipment
Equipment
Registration No. Manufacturer Model No. Serial No.
EMI Test Receiver EW-0015
R&S
ESHS30
827128/009
LISN EW-0090
R&S
ESH3-Z5
840731/0013
Pulse Limiter
EW-0698
R&S
ESH3-Z2
830.836/033
Notes: 1. A graph of Ctrl. No.: 4.3.1 consisting of one page and a data table of Ctrl
No.: 4.3.2 consisting of one page are attached.
2. Uncertainty: ±2.5 dB at a level of confidence of 95%
Ctrl. No.: 4.3
Report No.:
04173782
1/8 Out power
AC Mains
1/8 Out power
AC Mains
Ctrl No.:
4.3.
PAGE 1
Tested By:Hong, Report No.:04173782
Scan Settings (1 Range)
|--------- Frequencies -----------||----------- Receiver Settings ------------|
Start Stop Step IF BW Detector M-Time Atten Preamp OpRge
150k 30M 5k 10k PK+AV 10ms AUTO LN OFF 60dB
Final Measurement: x QP / + AV
Meas Time: 1 s
Subranges: 16
Acc Margin: 20dB
Transducer No. Start Stop Name
21 9k 30M EW0698
0
10
20
30
40
50
60
70
dBuV
80
0.15
MHz
30
1
10
13Q
13A
Report No.:
04173782
1/8 Out power
AC Mains
1/8 Out power
AC Mains
Ctrl No.:
4.3.
Tested By:Hong, Report No.:04173782
Scan Settings (1 Range)
|--------- Frequencies -----------||----------- Receiver Settings ------------|
Start Stop Step IF BW Detector M-Time Atten Preamp OpRge
150k 30M 5k 10k PK+AV 10ms AUTO LN OFF 60dB
Final Measurement Results:
Frequency QP Level QP Limit
MHz dBuV dBuV
0.15000 42.2 66.0
2.38500 32.9 56.0
Frequency AV Level AV Limit
MHz dBuV dBuV
2.35000 27.1 46.0
* limit
exceeded
exceeded
INTERTEK TESTING SERVICES
7 of 19
Applicant: Harman Consumer Group
Report No.: 04173782
Model: HK 970
Worst Case Operating Mode: Amplifying
Worst Case Operating Mode: Amplifying
EN61000-3-2
Harmonics
Test Observation Mode:
Amplifying
Rated Voltage:
230 V/50Hz
Test Voltage:
230V/50Hz
Test Observation Period:
2.5 min.
Specified Power:
N/A
Measured Power:
187.2461W
Fundamental Current:
0.8232A
Power Factor:
0.7496
Used Test Equipment
Equipment
Registration No. Manufacturer Model No.
Serial No.
Harmonic, Flicker
and Voltage Drop
Test System
and Voltage Drop
Test System
EW-1448
Schaffner
NSG1007-5-
400
400
54661
Three Power
Analyser
Analyser
EW-1781
Voltech
Instrument
Instrument
PM3000ACE AI103/8843
Reference
Impedance
Network
Impedance
Network
EW-1782
Voltech
Instrument
Instrument
UK 8729
Note:
A graph of Ctrl. No.: 5.1.1 consisting of one page and a data table of Ctrl No.:
5.1.2 consisting of one page are attached.
5.1.2 consisting of one page are attached.
Ctrl. No.: 5.1
Click on the first or last page to see other HK 970 (serv.man14) service manuals if exist.