DOWNLOAD Harman Kardon HK 970 (serv.man14) Service Manual ↓ Size: 3.83 MB | Pages: 33 in PDF or view online for FREE

Model
HK 970 (serv.man14)
Pages
33
Size
3.83 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-970-sm14.pdf
Date

Harman Kardon HK 970 (serv.man14) EMC - CB Certificate ▷ View online

INTERTEK TESTING SERVICES 
 
4 of 19
 
Report No.: 04173782 
 
Performance criteria for immunity 
 
The performance criteria are referred to the test standard: 
Performance criteria A 
The equipment shall continue to operate as intended during the test. No change of 
actual operating state (for example change of channel) is allowed as a result of the 
application of the test. Multifunction equipment shall for each function meet the 
relevant requirements. Evaluation is carried out for audio and video functions.  
 
Evaluation of audio quality 
The criterion of compliance with the requirement is a wanted to unwanted audio 
signal ratio of 
≥40 dB at a wanted audio signal level of 50 mW, or at another audio 
signal level specified by the manufacturer. If the S/N ratio is less than 43 dB, the 
performance criterion for audio assessment is the actual S/N ration minus 3 dB. For 
AM sound receivers the criterion is 
≥26dB at 50mW; and is ≥26dB at 500mW for the 
AM/FM car radio or broadcast receiver cards for computers.  
 
Evaluation of video quality 
In the evaluation of picture interference the wanted test signal produces a standard 
picture (in the case of video tape equipment on the screen of the test-TV-set) and 
the unwanted signal produces a degradation of the picture.  The degradation may be 
in a number of forms, such as a superposed pattern, disturbance of synchronization, 
geometrical distortion, loss of picture contrast, of colour, etc. 
The criterion of compliance with the requirement is just perceptible degradation by 
observation of the picture.  The screen shall be observed under normal viewing 
conditions (brightness 15 lx to 20 lx), at a viewing distance of six times the height of 
screen. 
 
Performance criteria B 
The equipment shall continue to operate as intended after the test. No loss of 
function is allowed after the test when the apparatus is used as intended, but failures 
which are recovered automatically but which cause temporary delay in processing, 
are permissible. No change of actual operating state for example change of channel 
or stored data and settings is allowed as result of the application of the test. During 
the test, degradation of performance is allowed. 
Ctrl. No.: 1.3.1
INTERTEK TESTING SERVICES 
 
5 of 19
 
Applicant: Harman Consumer Group 
Report No.: 04173782 
Model: HK 970 
Worst Case Operating Mode: Amplifying 
 
 
 
 
 
EN55013 
RFI Power Clamp Test
  
 
 
 
Used Test Equipment 
 
Equipment  
Registration No. Manufacturer  Model No.  Serial No. 
EMI Test Receiver  EW-0014 
R&S 
ESVS30 
842807/001 
Absorbing Clamp 
EW-0613 
R&S 
MDS21 
840031/001 
 
Notes:  1.  A graph of Ctrl. No.: 4.2.1 consisting of one page and a data table of Ctrl 
No.: 4.2.2 consisting of one page are attached. 
 
 
2.  Uncertainty: ±3.5 dB at a level of confidence of 95% 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Ctrl. No.: 4.2
Report No.:
04173782
1/8 Out power
Phone input
Ctrl No.:
4.2.
PAGE 1
Tested By:Hong, Report No.:04173782
Scan Settings (1 Range)
|--------- Frequencies -----------||----------- Receiver Settings ------------|
  Start       Stop         Step     IF BW  Detector  M-Time Atten Preamp OpRge
  30M        300M         50k        120k    PK+AV     1ms AUTO LN OFF   60dB
Final Measurement: x QP / + AV
                   Meas Time:    1 s
                   Subranges:   16
                   Acc Margin:  20dB
Transducer No. Start      Stop      Name
     1      1    30M      300M     EW1644
           21    30M      300M     EW0613
   0
  10
  20
  30
  40
  50
  60
  70
dBpW
  80
30
MHz
300
40
80
120
160
200
240
280
13Q
13A
Report No.:
04173782
1/8 Out power
Phone input
Ctrl No.:
4.2.
Tested By:Hong, Report No.:04173782
Scan Settings (1 Range)
|--------- Frequencies -----------||----------- Receiver Settings ------------|
  Start       Stop         Step     IF BW  Detector  M-Time Atten Preamp OpRge
  30M        300M         50k        120k    PK+AV     1ms AUTO LN OFF   60dB
Final Measurement Results:
Frequency    QP Level   QP Limit
   MHz        dBpW       dBpW
  30.40000     24.0      45.0
  57.40000     22.1      46.0
  72.10000     24.2      46.5
  81.10000     22.0      46.8
Frequency    AV Level   AV Limit
   MHz        dBpW       dBpW
  30.00000     20.4      35.0
              * limit
exceeded
Page of 33