Harman Kardon HK 3390 EMC - CB Certificate ▷ View online
-
Page 39 of 43 -
Report
No.
98502
14
TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference *)
Mains plug/cord
(For CENELEC)
(For CENELEC)
KENIC
ELECTRIC.
ELECTRIC.
KE-21
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. KENIC
ELECTRIC.
KE-32
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. PHINO
ELECT.
PHP-205
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt. VOLEX
(ASIA)
PTE.
M4206
H03VVH2-F
H03VVH2-F
2.5A/250V
6A/250V
6A/250V
IEC60884-1 VDE
alt.
KENIC
ELECTRIC.
ELECTRIC.
KE-25
H03VVH2-F
H03VVH2-F
10-16A/250V
6A/250V
6A/250V
IEC60884-1 VDE
Mains plug / cord
(For Korea)
(For Korea)
See “Summary of testing”
Mains plug/cord
(For UK and
Singapore)
(For UK and
Singapore)
KENIC
ELECTRIC.
ELECTRIC.
KE-108
H03VVH2-F, or
H05VVH2-F
H03VVH2-F, or
H05VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
SS145
SS145
BSI
PSB
PSB
Mains plug/cord
(For UK)
(For UK)
PHINO ELECT. PHP-307F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. VOLEX
(ASIA)
PTE.
MP5004A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. VOLEX
(ASIA)
PTE.
MP5005
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt. WINBO
INDUSTRIES
MS 323N
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
LUEN TAI (IP’S)
KENIC ELECT.
KENIC ELECT.
9518
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
alt.
WELL SHIN EN
TERPRISE.
TERPRISE.
WS-012A
H03VVH2-F
H03VVH2-F
13A/250V
6A/250V
6A/250V
BS1363
BS6500
BS6500
BSI
Main
transformer
Bobbin Material
alt.
alt.
Thermal fuse
transformer
Bobbin Material
alt.
alt.
Thermal fuse
Seoul Electronics
& Telecom Co
EI DUPONT.
Samyang Co Ltd.
WINTECH Poly.
& Telecom Co
EI DUPONT.
Samyang Co Ltd.
WINTECH Poly.
Anzen Dengu Co.
KLT5U021ZE
CLT5U021ZE
CLT5U021ZE
FR530
2550GN30
CN9030
2550GN30
CN9030
L7F
230V, Class B
PET, V-0,
155
°
C.
PET, V-0,
130
°
C.
PET, V-0,
155
°
C
5A/250V, 145℃
IEC60065
clause 14.3
UL94
UL94
UL94
clause 14.3
UL94
UL94
UL94
IEC60691
1.)
UL,
E69578
UL,
E116425
UL,
E213445
VDE
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065, 7.Edition
-
Page 40 of 43 -
Report
No.
98502
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference *)
Sub transformer
(T102)
(T102)
Bobbin Mtl.
alt.
alt.
Thermal fuse
Seoul Electronics
& Telecom Co
EI DUPONT.
WINTECH Poly.
Samyang Co Ltd.
& Telecom Co
EI DUPONT.
WINTECH Poly.
Samyang Co Ltd.
Anzen Dangu Co.
KLT5J033YE /
CLT5J033YE
FR530
CN9030
2550GN30
K11
CLT5J033YE
FR530
CN9030
2550GN30
K11
230V, Class E
PET, V-0, 155°C
PET, V-0, 155°C
PET, V-0, 140°C
PET, V-0, 155°C
PET, V-0, 155°C
PET, V-0, 140°C
1A/250V, 115
°C
IEC60065
clause 14.3
UL94
UL94
UL94
IEC60691
clause 14.3
UL94
UL94
UL94
IEC60691
1.)
UL, E69578
UL,
UL, E69578
UL,
E2131445
UL, E121254
VDE
VDE
Socket-outlet
(OL11) alt.
(OL11) alt.
Dae Ryung Elect.
Dongbo Industri.
Dongbo Industri.
A3-04-D007
A304D007
A304D007
2.5A/250V ~
2.5A/250V ~
2.5A/250V ~
IEC60884-1
IEC60884-1
IEC60884-1
NEMKO
NEMKO
NEMKO
Mains fuse
(F101)
alt.
alt.
(F101)
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Elect.
Littelfuse.
SUN Electronics
Walter Elect.
50T
218
218
004
5T
TSD
TSD
T4A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Outlet fuse
(F102)
alt.
alt.
(F102)
alt.
alt.
Littelfuse B.V.
Bel Fuse.
Save Fusetech.
Wickmann-Werk.
Bel Fuse.
Save Fusetech.
Wickmann-Werk.
0663
MRT
SR-5
TR5 382
MRT
SR-5
TR5 382
T2.5A 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Sec. fuse
(F603, F604)
alt.
alt.
(F603, F604)
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Elect.
Littelfuse.
SUN Electronics
Walter Elect.
50T
218
218
06.3
5T
TSD
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Relay across
the cap (C108)
alt.
alt.
alt.
the cap (C108)
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC
60384-14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
X-cap. (C109)
alt.
alt.
alt.
alt.
alt.
alt.
alt.
alt.
Yuchang Elect.
Pilkor Electronics.
Pilkor Electronics.
Okaya Electric
Ultra Tech Xiphi.
Pilkor Electronics.
Pilkor Electronics.
Okaya Electric
Ultra Tech Xiphi.
WBU1942
PCX2 335M
PCX2 335
RE104
HQX
PCX2 335M
PCX2 335
RE104
HQX
0.10uF, 275V
X2
X2
IEC60384-14,
2
2
nd
ed.
FIMKO
FIMKO
SEMKO
FIMKO
FIMKO
FIMKO
SEMKO
FIMKO
FIMKO
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065, 7.Edition
-
Page 41 of 43 -
Report
No.
98502
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference *)
Mains switch
across the cap
(C123)
alt.
alt.
alt.
across the cap
(C123)
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.00047uF/250V,
X1.
X1.
IEC
60384-14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
Mains relay
(RY11)
(RY11)
Tyco Electronics SDT-S-112DMR 8A/120A 250V
IEC60065
IEC 61058-1
IEC 61058-1
SEMKO
Mains switch
Jackson Elect.
JS-606
6A 250V
IEC60065
IEC61058-1
FIMKO
Body, top cover
Front panel
alt.
Display window
alt.
Front panel
alt.
Display window
alt.
Various
Kumho Chemical
Various
Mitsubishi Rayon
Various
Kumho Chemical
Various
Mitsubishi Rayon
Various
Various
HFA-452
Various
L530
Various
HFA-452
Various
L530
Various
Sheet Steel,
Min. 0.80 mm
V-2, Min. 2.0 mm
V-2 or better
Min. 2,0mm thick
HB, Min. 2.0 mm
HB or better
Min. 2,0mm thick
Min. 0.80 mm
V-2, Min. 2.0 mm
V-2 or better
Min. 2,0mm thick
HB, Min. 2.0 mm
HB or better
Min. 2,0mm thick
-
UL94
UL94
UL94
UL94
UL94
UL94
UL94
UL94
1.)
UL, E65424
UL,
UL, E54695
UL,
UL, E65424
UL,
UL, E54695
UL,
PCB Various
Various
Min. V-0, 130
°C UL 796
UL
*) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively
1.) Tested as part of the Apparatus according to IEC 60065, 7.Edition
-
Page 42 of 43 -
Report
No.
98502
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Class II apparatus
N/A
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus
N/A
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
P
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
Class II apparatus
N/A
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
P
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
Class II apparatus.
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
BSI approved plug and cord
provided
provided
P
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
When marketing in Ireland,
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
the apparatus must be
supplied with a cord and plug
acceptable in Ireland.
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
P
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
Comply
P
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
Comply
P
- protecting rim also tested
Class II apparatus
N/A
Click on the first or last page to see other HK 3390 service manuals if exist.