DOWNLOAD Harman Kardon HK 3390 Service Manual ↓ Size: 1.81 MB | Pages: 57 in PDF or view online for FREE

Model
HK 3390
Pages
57
Size
1.81 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-3390.pdf
Date

Harman Kardon HK 3390 EMC - CB Certificate ▷ View online

 
 
- Page 15 of 43 - 
 
 
 
 
 Report 
No. 
98502 
 
 
 
13.3 Clearances 
2N for internal parts and 
30N for enclosures are 
considered when 
determining clearances. 
13.3.1 General 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
See attachment, Table to 
EN/IEC 60065 7
th
 edition.
 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
No hazardous secondary 
voltages
 
N/A 
13.3.4 
Measurement of transient voltages 
No measurement of 
transient voltages 
N/A 
13.4 Creepage 
distances 
CTI > 100 
See attachment, Table to  
EN/IEC 60065 7
th
 edition. 
 
 
Creepage distances greater than table 11 minima 
Not applicable
 
N/A 
13.5 Printed 
boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of 
which may be conductively connected to the 
mains, as in fig. 10 
No such PCB used
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
No type B coated printed  
circuit boards
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
Jointed insulation not 
applied
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
 
Temperature cycle test and dielectric strength test
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
No enclosed, enveloped or 
hermetically sealed parts
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
No parts filled with 
insulating compound.
 
N/A 
 
 
- Page 16 of 43 - 
 
 
 
 
 Report 
No. 
98502 
 
 
 
14 COMPONENTS 
 
14.1 Resistors 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors
 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
Not used
 
N/A 
 Resistors 
separately approved  .......................... : 
 
N/A 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes  
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition : 
No Y capacitors
 
N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition : 
C108, C109 and C123  
capacitors are Certified  
components by  
IEC 60384-14, 2
nd
 edition 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ................. : 
No such capacitors
 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better  ...................................................................... : 
Several E. capacitors 
Volume >1750mm
3
, but 
metal cases. 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ..................................... : 
Several E. capacitors 
Volume >1750mm
3
, but 
metal cases. 
N/A 
 
Shielded by a barrier 
acc. to 20.1.4/ table 21
 or 
metal  ....................................................................... : 
 
N/A 
14.3 
Inductors and windings 
See below.
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
Transformers evaluated  
according to 14.3.3, 14.3.4 
and 14.3.5
 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ........................... : 
Adequate marking applied. 
Mfr. ID and type no. 
 
Transformers and inductors separately approved 
 ................................................................................. : 
No 
N/A 
14.3.2 General 
Isolating transformer
 
 
Insulation material complies  with clause 20.1.4 
 
 
 
- Page 17 of 43 - 
 
 
 
 
 Report 
No. 
98502 
 
 
 
14.3.3 Constructional 
requirements 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
See attachment, Table to 
EN/IEC 60065 7
th
 edition.
 
14.3.3.2 
Transformers meet the constructional 
requirements 
See attachment, Table to  
EN/IEC 60065 7
th
 edition.
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible 
parts (double or reinforced insulation) 
Double or reinforced  
insulation between primary  
and secondary windings  
according to clause 8.8. 
See attachment, Table to  
EN/IEC 60065 7
th
 edition. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin of transformers 
fulfils the requirement of  
reinforced insulation;  
bobbin thickness > 0,4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Transformers are evaluated 
with Class II construction
 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
Windings of Class II  
construction used.
 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible 
parts (double or reinforced insulation) 
Double or reinforced  
insulation between  
hazardous live windings  
and accessible conductive  
parts. 
 
Coil formers and partition walls > 0,4 mm 
The bobbins fulfils the  
requirement of reinforced  
insulation; bobbins thickness 
> 0,4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Windings of Class II  
construction used.
 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
         
 
N/A 
 
 
- Page 18 of 43 - 
 
 
 
 
 Report 
No. 
98502 
 
 
 
14.4 
High voltage components 
No high-voltage 
components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested 
as part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 Protective 
devices 
 
 
Protective devices used within their ratings 
Thermal links and fuses
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across 
the device when opened 
Certified protective devices 
applied.   
See appended table, list of 
critical component. 
14.5.1.1 
a) Thermal cut-outs separately approved 
No thermal cut-outs.
 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
The thermal links in  
main and sub transformer 
separately approved.  
See appended table, list of  
critical components
 
 
b) Thermal links tested as part of the submission   
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
No thermal devices 
re-settable
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
Fuses are approved 
components according to 
IEC 60127.
 
See list of critical components
 
14.5.2.2 
Correct marking of fuse-links adjacent to holder 
 ................................................................................. : 
Correct marking applied 
close to the fuse; 
F101: T4A L 250V, 
F102: T2.5A L 250V, 
F603, F604: T6.3A L 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ......... : 
No fuses holder so 
designed that fuse-links  
can be connected in parallel 
Page of 57
Display