Report
No.
98502
Copy of marking plate and summary of test results (information/comments):
- Page 4 of 43 -
Report
No.
98502
Summary of testing:
The apparatus under test is A/V Receiver of insulation class II.
The apparatus have Amplifier Circuits, Tuner Circuit, Several Signal In/Out terminals
(RCA, Antenna, Mini jack) and Speaker terminal provided (see also photos).
The model, HK 3390/230 will have two different mains input rating as follows,
- 220V 60Hz or 220-230V 50/60Hz.
The apparatus have Amplifier Circuits, Tuner Circuit, Several Signal In/Out terminals
(RCA, Antenna, Mini jack) and Speaker terminal provided (see also photos).
The model, HK 3390/230 will have two different mains input rating as follows,
- 220V 60Hz or 220-230V 50/60Hz.
The 220V input rating apparatus is only to be marketed in Korea.
The 220-230V input rating apparatus is only to be marketed in CENELEC countries and Singapore.
The 220V input rating is within range of tested 220-230V mains inputs, and limited tests were performed.
Plug / External flexible cords : The appliance shall be provided with an approved mains plug
and cord complying with the national regulations of the countries in which the appliance is to be sold.
and cord complying with the national regulations of the countries in which the appliance is to be sold.
Instructions: Instructions/users manual is only in English. The information shall be given in a language
acceptable to the country where the apparatus is intended to be sold.
List of attachments:
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
ANNEX ZC TO EN 60 065, A-DEVIATIONS
National Deviations for Singapore
Attachment, Tables to EN/IEC 60065 7
ANNEX ZC TO EN 60 065, A-DEVIATIONS
National Deviations for Singapore
Attachment, Tables to EN/IEC 60065 7
th
edition
Photos.
- Page 5 of 43 -
Report
No.
98502
Test item particulars .................................................. :
A/V Receiver
Classification of installation and use ...................... :
Class II apparatus
Supply connection .................................................... :
By non-detachable power supply cord to mains socket.
Possible test case verdicts:
- test case does not apply to the test object ........... :
N/A
- test object does meet the requirement .................. :
Pass (P)
- test object does not meet the requirement ........... :
Fail (F)
Testing:
Date of receipt of test items………………………….:
December 18, 2007
Date(s) of performance of tests ................................ :
December 18, 2007 - January 10, 2008
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (coma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
The sample(s) tested complies with the requirements of IEC 60065: 2001 + A1: 2005 / EN 60065: 2002
+ A1: 2006. Compliance with European Special National Conditions, Annex ZB, and A – Deviations,
Annex ZC, and tested according to national requirements for the following countries;
All CENELEC Countries listed in EN60065: 2002, Singapore and Korea, but Korean deviations are not
included in this report (not announced yet).
+ A1: 2006. Compliance with European Special National Conditions, Annex ZB, and A – Deviations,
Annex ZC, and tested according to national requirements for the following countries;
All CENELEC Countries listed in EN60065: 2002, Singapore and Korea, but Korean deviations are not
included in this report (not announced yet).
- Page 6 of 43 -
Report
No.
98502
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ............................. :
Class II apparatus
—
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
No test box required.
Tested according to
manufacturer’s instructions
Tested according to
manufacturer’s instructions
N/A
5 MARKING
Comprehensible and easily discernible
On front and rear side of
the enclosure.
the enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water / spirit
P
5.1 Identification,
maker, model ............................... :
Maker: “Harman / Kardon”
Model: “HK 3390/230.”
See copy of marking plate
Model: “HK 3390/230.”
See copy of marking plate
P
Class II symbol if applicable
Class II symbol is applied
in according to IEC 60417-
5172
in according to IEC 60417-
5172
P
Rated supply voltage and symbol ...................... :
“220V-230V” or “220V”
and AC-symbol (
~
) used.
P
Frequency if safety dependant
“50/60 Hz” or “60Hz”
P
Rated current or power consumption ............... :
230W
P
5.2 Earth
terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
The output signal will rise to
36Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
36Vpeak at maximum out
power if the speaker output
load is disconnected.
No hazard.
P