Harman Kardon HD 980 (serv.man4) EMC - CB Certificate ▷ View online
Test report no. SH08050534-001
Page 8 of 67
2.3 Instrument List
Selected Instrument
EC no.
Model
Valid until date
EMI test receiver
EC 2107
ESCS 30
2009-1-16
A.M.N.
EC
3119 ESH2-Z5 2009-1-16
Absorbing clamp
EC 2108
MDS 21
2009-1-16
ESD
Gun
EC
2956 ditto
2009-1-17
Motorise Variac
EC 2957
MV 2616
Not required
Immunity system
EC 2958
UCS500M6
2009-1-16
Power sensor
EC 3043-7
PH 2000
2009-1-16
Power meter
EC 3043-8
PM 2002
2009-1-16
Signal
generator EC
3044-1
SMR20 2008-8-20
Power amplifier
EC 3044-2
150W1000
2008-8-20
Field
sensor
EC
3044-3
FP6001 2008-8-20
Fully anechoic chamber EC 3047
-
2008-7-12
Shielded
room
EC
2838 GB88
2009-2-3
Shielded
room
EC
2839 GB88
2009-2-3
Thermo-Hygrograph
EC
3323 ZJ1-2A 2009-1-09
Thermo-Hygrograph
EC
3783 ZJ1-2A 2009-1-28
Thermo-Hygrograph
EC
3326 ZJ1-2A 2008-12-20
Air pressure indicator
EC 3320
YM3
2009-3-22
Test report no. SH08050534-001
Page 9 of 67
2.4 Test Summary
This report applies to tested sample only. This report shall not be reproduced in
part without written approval of Intertek Testing Service Shanghai Limited.
part without written approval of Intertek Testing Service Shanghai Limited.
TEST ITEM
RESULT
NOTE
Disturbance voltage at the mains terminals
Pass
Disturbance voltage at the antenna terminals
NA
Disturbance power
Pass
Radiated emission
NA
Harmonics Pass
Flicker Pass
S1 NA
S2 Pass
S3 Pass
S4 NA
ESD Pass
EFT Pass
S5 Pass
Notes: NA =Not Applicable
Test report no. SH08050534-001
Page 10 of 67
Emission Test
3. Disturbance voltage at the mains terminals
Test result:
PASS
3.1 Limits of disturbance voltage at the mains terminals
Frequency range
(MHz)
Limits dB(
µv)
Quasi-peak Average
0.15 ~ 0.5
66 ~ 56 *
59 ~ 46 *
0.5 ~ 5
56
46
5 ~ 30
60
50
Note: 1. * means the limit decreasing linearly with the logarithm of the frequency.
2. If the limits for the average detector are met when using the quasi-peak
detector, then the limits for the measurements with the average detector
are considered to e met.
are considered to e met.
3.2 Test setup
3.3 Test Setup and Test Procedure
Test report no. SH08050534-001
Page 11 of 67
Measurement was performed in shielded room.
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
Instruments used were following CISPR 16-1.
Measurement methods and operation conditions of EUT was according to clause 5.2
and 5.3 of EN55013
Frequency range 150kHz – 30MHz was checked and EMI receiver measurement’s
bandwidth was set to 9 kHz.
3.4 Test Protocol
Temperature :
22
°C
Relative Humidity
:
40%
Test Curve: