DOWNLOAD Harman Kardon GO AND PLAY (serv.man3) Service Manual ↓ Size: 3.09 MB | Pages: 80 in PDF or view online for FREE

Model
GO AND PLAY (serv.man3)
Pages
80
Size
3.09 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm3.pdf
Date

Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
49 of 80 
 
8.4.  Power Line Fluctuations / Flicker Test Results 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
50 of 80 
 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
51 of 80 
 
 
Power Line Harmonics and Flicker Test Equipment 
Client 
Harman Multimedia 
Temperature 78 
deg 
PAN # 
26-635-HAR
 R1
 
Relative Humidity 
60 
EUT Name 
Audio/Peripheral System 
Barometric Pressure 
30.21  Hg 
EUT Model  
Go + Play 
Test Location 
West Ground Plane 
Governing Doc 
EN 55022 
Test Engineer 
Juan Garcia 
Basic Standard 
IEC 61000-3-2 and  
IEC 61000-3-3 
Date 07/20/06 
 
 
EUT Voltage: 
X  230VAC @ 50Hz 
 
120VAC @ 60Hz 
 
 
 
 
 
 
Equipment Used Used Asset 
# Cal 
Done Cal 
Due 
California Instruments AC Power 
604 NCR 
NCR 
Xitron 2520 Standard Impedance 
581 1/3/06 
1/3/07 
Xitron 2503AH Power Analysis System 
582 1/3/06 
1/3/07 
 
 
 
 
 
 
Photo X 
 
 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
52 of 80 
 
8.5.  Electrostatic Discharge Immunity Test Results & Test Points 
 
Client: 
Harman Multimedia 
Temperature: 79 
degF 
PAN #: 
26-635-HAR
 R1
 
Relative Humidity: 
61 
EUT Name: 
Audio/Peripheral System 
Barometric Pressure: 
30.14 
Hg 
EUT Model: 
Go + Play 
Test Location 
Enclosure 2 
Governing Doc: 
EN 55024 
Test Engineer 
Juan Garcia 
Basic Standard: 
EN 61000-4-2 
Date: 
July 27, 2006 
Voltage: 230VAC/ 
50Hz 
Discharge Rep. Rate 
> 1 per second 
 
 
Number of Discharges 
> 10 per location 
 
 
Equipment Used 
Device Type 
Model # 
Asset # 
Used 
Cal Done 
Cal Due 
ESD Gun, Haefely 
PSD-25B 
639 
 
 
 
ESD Gun, Keytek 
PSC 
377 
 
 
 
ESD Gun, Schaffner 
NSG 435 
818 
 
 
 
EMC Partner 
Transient 2000 
845 
3/15/06 
3/15/07 
EMC Partner 
ESD 2000 
890 
3/14/06 
3/14/07 
 
Location of Discharge 
Contact Discharge 
Polarity 
Voltage 
(kV) 
Pos Neg 
Numbers HCP  VCP 
2 X X 
4 X X 
 
 
 
 
 
 
Comments:  Volume dipped and went back to normal every other 4kv discharge on buttons and all 4 sides of 
horizontal ground plane 
 
Air Discharge 
Polarity 
Voltage 
(kV) 
Pos Neg 
Numbers 
2 X X 
4 X X 
8 X X 
 
 
 
 
 
Comments:    
 
Compliant X 
 
Non-Compliant 
  
 
Photo X  
 
Page of 80
Display