Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
57 of 80
8.7. Electrical Fast Transient Burst Immunity Test Results
Client
Harman Multimedia
Temperature 79
deg
F
PAN #
26-635-HAR
R1
Relative Humidity
49
%
EUT Name
Audio/Peripheral System
Barometric Pressure
30.14
Hg
EUT Model
Go + Play
Test Location
Enclosure 2
Governing Doc
EN 55024
Test Engineer
Juan Garcia
Basic Standard
EN 61000-4-4
Date
July 27, 2006
Test Level:
AC / DC Mains / Control Ports
X 0.5kV
X 1.0kV
2.0kV
4.0kV
______
Signal
Ports
X 0.25kV
X 0.5kV 1.0kV
2.0kV ______
Test Duration:
X 61
sec
_______
Test Equipment
Asset # Used Calibration
Done Calibration
Due
Haefely P90.1 Generator
416
Haefely 093 506.1 Clamp
417
X
NCR
NCR
Haefely FP-EFT Generator 32.1
689
Noiseken FNS-100L
547
Noiseken 15-00001A Clamp
802
NCR
NCR
EMC Partner Transient 2000
845
X
3/15/06
3/15/07
Performance Criteria:
A
X B
C
Direct Injection Output Path
Test Level
Polarity
(+/-)
L1 L2 PE
Comments
1.0kV +/- X
1.0kV
+/-
X
1.0kV +/- X
X
.5kV
+/-
Coupling Clamp: S-Video Cable
.5kV
+/-
Coupling Clamp: ‘White Cable 2’ Audio Cable
.5kV
+/-
Coupling Clamp: USB Cable
Cable Description (Clamp Injection) Polarity
S-Video Cable
‘White Cable 2’ Audio Cable
USB Cable
Compliant X
Non-Compliant
Photo
X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
58 of 80
8.8. Power Line Surge Immunity Test Results
Client
Harman Multimedia
Temperature 81
deg
F
PAN #
26-635-HAR
R1
Relative Humidity
75
%
EUT Name
Audio/Peripheral System
Barometric Pressure
30.21 Hg
EUT Model
Go + Play
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Juan Garcia
Basic Standard
EN 61000-4-5
Date
July 28, 2006
EUT Power:
Number of Strikes per Polarity/Voltage:
Repetition # Angle
X 230VAC @ 50Hz
X Five (5)
1
0º
230/400VAC @ 50 Hz
Twenty (20)
2
90º
120VAC @ 60 Hz
3
180º
4
270º
5
360º
Waveform Generator Type:
Ring
Wave X
Combination
Test Equipment: Asset
# Used Calibration
Done Calibration
Due
Haefely PSurge 4010
687
Haefely FP Surge 32.1
688
NCR
NCR
Haefely PC6 288.1
413
Haefely FP Surge 16.1
412
NCR
NCR
EMC Partner Transient 2000
845
X
3/15/06
3/15/07
Performance
Criteria: A X
B C
L - Gnd
0.5kV (Level 1)
1.0kV (Level 2)
2.0kV (Level 3)
4.0kV (Level 4)
??kV (Special)
L - L
X 0.25kV (Level 1) X 0.5kV (Level 2)
X 1.0kV (Level 3)
2.0kV (Level 4)
??kV (Special)
Level 1
Level 2
Level 3
Level 4
Special
CM DM CM DM CM DM CM DM CM DM
0.5kV
0.5kV
0.25kV
1.0kV
0.5kV
2.0kV
1.0kV
4.0kV
2.0kV
+ - + - + - + - + - + - + - + - + - + -
N–Gnd
L1–Gnd
N-L1
X X
X X
X X
Compliant X
Non-Compliant
Photo X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
59 of 80
8.9. RF Conducted Common Mode Disturbance Immunity Test Results
Client
Harman Multimedia
Temperature 77
deg
C
PAN #
26-635-HAR
R1
Relative Humidity
60
%
EUT Name
Audio/Peripheral System
Barometric Pressure
30.15
Hg
EUT Model
Go + Play
Test Location
West Ground Plane
Governing Doc
EN 55024
Test Engineer
Juan Garcia
Basic Standard
EN 61000-4-6
Date
August 1, 2006
Test Level: X
3Vrms
10Vrms
Modulation:
None (CW)
X 80%AM @ 1kHz
Frequency Range: X
0.15 – 80 MHz
0.15-230MHz
Step: X
1%
10%
1.5 x 10¯³ /decade
Performance Criteria: X
A
B
1 Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
2 Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
3 Injection Point (Cable)
Injection Method:
Clamp
CDN
Comments:
4 Injection Point (Cable)
Injection Method:
Comments:
5 Injection Point (Cable)
Injection Method:
Comments:
Test Equipment Used
Asset #
X if Used Calibration
Done Calibration
Due
HP 8462B (Signal Generator)
751
Fluke 6060B (Signal Generator)
212
HP 8648B (Signal Generator)
746
X
10/31/05
10/31/06
FCC-801-M1-25 (CDN)
473
FCC-801-M2-25 (CDN)
472
X
8/12/05
8/12/06
FCC-801-M3-25A (CDN)
846
X
3/30/06
3/30/07
FCC-801-M4-25 (CDN)
628
FCC-801-M5-25 (CDN)
629
FCC-801-T2 (CDN)
626
FCC-801-T4 (CDN)
627
AR 2500L (Amplifier)
739
X
NCR
NCR
IFI 1500 (Amplifier)
571
NCR
NCR
RF Power Labs (Amplifier)
397
NCR
NCR
Solar 9144-1N (Clamp)
436
Solar 9121-1N (Clamp)
435
Solar 6741-1N (Clamp)
144
Compliant X
Non-Compliant
Photo X
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
60 of 80
8.10.Power Frequency Magnetic Field Immunity
Client:
Harman Multimedia
Temperature:
81 degF
PAN #:
26-635-HAR
R1
Relative Humidity:
75
%
EUT Name:
Audio/Peripheral System
Barometric Pressure:
30.21
Hg
EUT Model:
Go + Play
Test Location:
West Ground Plane
Governing Doc:
EN 55024
Test Engineer:
Juan Garcia
Basic Standard:
EN 61000-4-8
Date:
July 28, 2006
Voltage: 230VAC
50Hz
Frequency:
DC
60Hz
X 50Hz
Threat Level:
1A/m
X 3A/m
Duration Per Axis:
X
5
Min
Criteria:
X
A
B
C
Test Equipment List
Equipment
Asset #
Used
Calibration Done
Calibration Due
Magnetic Induction Coil
821
X
NCR
NCR
ELGAR Power Supply
220
X
NCR
NCR
Narda Exposure Level Tester
851
X
NCR
NCR
Narda Field Probe
852
X
Compliant
Test Axis
Y
N
Comments
X
X
No Susceptibility Noted
Y
X
No Susceptibility Noted
Z
X
No Susceptibility Noted
Photo
X
Click on the first or last page to see other GO AND PLAY (serv.man3) service manuals if exist.