<12007721 001> 
 
 
Page 87 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Japanese National Differences according to CB Bulletin No. 105A, May 2003 
 
5.3.8.2 
Replacement: 
Replace 3rd item as follows. 
BASIC INSULATION between the PRIMARY 
CIRCUIT and accessible conductive parts of 
CLASS I or 0I EQUIPMENT; 
Replaced. 
Annex A 
Addition: 
Add the subclause A.101 with the title 
“Flammability tests for classifying materials VTM” 
and the following: 
Thin sheet materials shall comply with ISO 9773. 
Added. 
Annex G 
Addition: 
Add the following to the Note for Table G.1. 
2. In Japan, MAINS TRANSIENT VOLTAGE for 
equipment with a Nominal AC MAINS SUPPLY 
VOLTAGE of 100 V is to be decided based on the 
column where Nominal AC MAINS SUPPLY 
VOLTAGE in Table G.1 is 150 V. 
Added. 
Annex P 
Addition: 
Add “IEC 61965:2000, Mechanical Safety for 
Cathode Ray Tubes”. 
Added. 
Annex U 
Replacement: 
Replace 2nd paragraph. 
This annex covers to round winding wires having 
diameters between 0.05 mm and 5.00 mm. 
Winding material of 
transformer T1 in compliance 
with Annex U of IEC 
60950:1999. For component 
approval(s) refer to table 1.5.1 
of this test report. 
U.2.1 
Replacement: 
Electric strength 
The test sample is prepared according to IEC 
60851-5:1997, 4.4.1 (for a twisted pair). The 
sample is then subjected to the test of 5.2.2 of 
this standard, with a test voltage not less than 
twice the appropriate voltage in table 5B (see 
5.2.2) of this standard. However, the minimum 
values shall be as follows: 
for BASIC INSULATION or SUPPLEMENTARY 
INSULATION, 3000 V, or; 
for REINFORCED INSULATION, 6000 V. 
Ditto. 
 
 
<12007721 001> 
 
 
Page 88 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Japanese National Differences according to CB Bulletin No. 105A, May 2003 
 
U.2.2 
Replacement: 
Flexibility and adherence 
Test 8 of IEC 60851-3:1996, 5.1.1, using the 
mandrel diameters of table U.1. The test sample 
is then examined in accordance with IEC 60851-
3:1996, 5.1.1.4, followed by the test of 5.2.2 of 
this standard except applying the test voltage 
between the wire and the mandrel. A test voltage 
shall not be less than twice the appropriate 
voltage in table 5B (see 5.2.2) of this standard. 
However, the minimum values shall be as 
follows: 
for BASIC INSULATION or SUPPLEMENTARY 
INSULATION, 1500 V, or; 
for REINFORCED INSULATION, 3000 V. 
Ditto. 
Replacement: 
Mandrel diameter 
Nominal Conductor diameter 
mm 
Mandrel diameter 
mm ± 0,2 mm 
0,05 – 0,34 
4,0 
0,35 – 0,49 
6,0 
0,50 – 0,74 
8,0 
0,75 – 2,49 
10,0 
2,50 – 5,00 
4 times of the diameter of conductor 
1)
 
1)
 in compliance with IEC 60317-43. 
Table U.1 
The tension to be applied to the wire during winding on the mandrel is calculated 
from the wire diameter to be equivalent to 118 MPa ± 10 % (118 N/mm
2
 ± 10 %). 
 
 
<12007721 001> 
 
 
Page 89 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Korean National Differences according to CB Bulletin, No. 105A, May 2003 
APPENDIX  Korean National Differences according to CB Bulletin, No. 105A, May 2003 
(K60950) 
(IEC Publication 60950:1999) 
EXPLANATION FOR ABBREVIATIONS 
P=Pass, F=Fail, N=Not applicable. Placed in the column to the right. 
1.5.101 
Addition: 
Plugs for the connection of the apparatus to the 
supply mains shall comply with the Korean 
requirements (KSC 8305). 
No plug provided. 
Addition: 
EMC 
The apparatus shall comply with the relevant 
CISPR standards. 
Shall be evaluated when 
submitted for national 
approval. 
 
 
<12007721 001> 
 
 
Page 90 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
US National Differences according to CB Bulletin No. 105A, May 2003 
 
APPENDIX  US National Differences according to CB Bulletin No. 105A, May 2003 
(UL 60950) 
(IEC Publication 60950:1999) 
EXPLANATION FOR ABBREVIATIONS 
P=Pass, F=Fail, N=Not applicable. Placed in the column to the right. 
Special National Conditions 
1.1.1 
All equipment is to be designed to allow 
installations in accordance with the National 
Electrical Code (NEC), ANSI/NFPA 70, and, 
unless marked or otherwise identified, the 
Standard for the protection of Electronic 
Computer/Data-Processing Equipment, 
ANSI/NFPA 75. 
Unit was evaluated according 
to IEC 60950.   
The requirements have to be 
checked during national 
approval. 
1.5.5 
For lengths exceeding 3.05 m, external 
interconnecting flexible cord and cable 
assemblies are required to be a suitable cable 
type (e.g. DP, CL2) specified in the NEC. 
For lengths 3.05 m or less, external 
interconnecting flexible cord and cable 
assemblies which are not types specified in the 
NEC are required to have special construction 
features and identification markings.  
No power supply cord 
provided.  
1.7.1 
Equipment for use on supply systems with a 
neutral and more than one phase conductor (e.g. 
120/240 V, 3-wire) require a special marking 
format for electrical ratings. 
A voltage rating that exceeds an attachment plug 
cap rating is only permitted if it does not exceed 
the extreme operating conditions in Table 2 of 
CAN/CSA C22.2 No. 235, and if it is part of a 
range that extends into the Table 2 “Normal 
Operating Conditions.” Likewise, a voltage rating 
shall not be lower than the specified “Normal 
Operating Conditions,” unless it is part of a range 
that extends into the “Normal Operating 
Conditions.” 
Single phase. 
2.5 
Where a fuse is used to provide Class 2, LPS (or 
TNV) current limiting, it shall not be operator-
accessible unless it is not interchangeable. 
Fuse within the unit, no 
operator accessible. 
2.7.1 
Suitable NEC branch circuit protection is required 
for all standard supply outlets, receptacles and 
medium-base or smaller lampholders if the 
supply branch circuit protection is not suitable. 
Power distribution transformers distributing power 
at 100 volts or more, and rated 10 kVA or more, 
require transformer overcurrent protection. 
No standard supply outlets. 