DOWNLOAD Harman Kardon GO AND PLAY (serv.man2) Service Manual ↓ Size: 2.53 MB | Pages: 115 in PDF or view online for FREE

Model
GO AND PLAY (serv.man2)
Pages
115
Size
2.53 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm2.pdf
Date

Harman Kardon GO AND PLAY (serv.man2) EMC - CB Certificate ▷ View online

 
 
<12007721 001> 
 
 
Page 79 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Canadian National Differences according to CB Bulletin No. 105A, May 2003 
 
3.4.10 
For computer room applications, equipment with 
battery systems capable of supplying 750 VA for 
five minutes are required to have a battery 
disconnect means that may be connected to the 
computer room remote power-off circuit. 
No battery. 
4.3.12 
The maximum quantify of flammable liquid stored 
in equipment is required to comply with NFPA 30. 
No flammable liquid. 
4.3.13 
Equipment with lasers is required to meet Code 
of Federal Regulations 21 CFR 1040 and/or 
Canadian Radiation Emitting Devices Act, REDR 
C1370, as applicable. 
No laser. 
4.7.1 
For computer room applications, automated 
information storage systems with combustible 
media greater than 27 cubic feet are required to 
have a provision for connection of either 
automatic sprinklers or a gaseous agent 
extinguishing system with an extended discharge. 
Not information storage 
systems.  
4.7.3.1 
For computer room applications, enclosures with 
combustible material measuring greater than 0.9 
m² or a single dimension greater than 1.8 m, are 
required to have a flame spread rating of 50 or 
less. For other applications, enclosures with the 
same dimensions require a flame spread rating 
of 200 or less. 
No such enclosure. 
Annex H 
Equipment that produces ionizing radiation is 
required to comply with Code of Federal 
Regulations, 21 CFR 1020 and/or Canadian 
Radiation Emitting Devices Act, REDR C1370, as 
applicable. 
No ionizing radiation. 
Other Differences 
1.5.2 
Components of equipment must be suitable for 
the application, and must comply with the 
requirements of the equipment standard and the 
applicable national (Canadian and/or U.S.) 
component or material standards, as far as they 
may apply. 
The acceptance will be based on the following: 
A component Certified by a Canadian or U.S. 
National Certification Body (NCB) to a Canadian 
or U.S. component standard will be checked for 
correct application and use in accordance with its 
specified rating. Where necessary, it will also be 
subject to the applicable tests of the equipment 
standard. 
A component which has a CB Test Certificate for 
compliance with a relevant IEC component 
standard will be checked for correct application 
and use in accordance with its specified ratings. 
Where necessary, it will also be subject to the 
For component, see table 
1.5.1 of report IEC 60950. 
 
 
<12007721 001> 
 
 
Page 80 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Canadian National Differences according to CB Bulletin No. 105A, May 2003 
 
applicable tests of the equipment standard, and 
to the applicable tests of the Canadian and/or 
U.S. component or material standard, under the 
conditions occurring in the equipment. 
A component, which has no approval as in A) or 
B) above or which is used not in accordance with 
its specified ratings, will be subject to the 
applicable tests of the equipment standard, and 
to the applicable tests of the Canadian and/or 
U.S. component or material standard, under the 
conditions occurring in the equipment. 
Some components may require annual re-testing, 
which may be carried out by the manufacturer, 
CSA International or another laboratory. 
2.3.1 
For TNV-2 and TNV-3 circuits with other than 
ringing signals and with voltages exceeding 
42.4 Vp or 60 Vd.c., the maximum acceptable 
current through a 2000 ohm resistor (or greater) 
connected across the voltage source with other 
loads disconnected is 7.1 mA peak or 30 mAd.c. 
under normal operating conditions. 
No TNV. 
2.6.3.3 
When subject to impedance testing, protective 
earthing and bonding are required to be tested to 
the additional test conditions that originate in 
CAN/CSA C22.2 No. 0.4. 
No TNV. 
4.2.8.1 
Enclosures around CRTs having a diagonal 
dimension of 160 mm or more are required to 
reduce the risk of injury due to the implosion of 
the CRT. 
No CRT. 
4.3.2 
Equipment with handles is required to comply 
with special loading tests. 
No handles. 
5.1.8.1.1 
Equipment intended to receive 
telecommunication ringing signals is required to 
comply with a special touch current measurement 
tests. 
No TNV. 
6.2.1 
Enamel coating on winding wire not considered 
electrical separation unless subject to special 
investigation. 
No TNV. 
6.4 
Equipment intended for connection to 
telecommunication network outside plant cable is 
required to be protected against overvoltage from 
power line crosses in accordance with 6.4 and 
Annex NAC. 
No TNV. 
6.5 
Equipment connected to a telecommunications 
network and supplied with an earphone intended 
to be held against, or in the ear is required to 
comply with special acoustic pressure tests. 
No TNV. 
 
 
<12007721 001> 
 
 
Page 81 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Canadian National Differences according to CB Bulletin No. 105A, May 2003 
 
M.2 
Continuous ringing signals up to 16 mA only are 
permitted if the equipment is subject to special 
installation and performance restrictions. 
No ringing signals. 
Annex NAB  Equipment connected to centralized d.c. power 
systems is required to comply with special 
earthing, wiring, marking and insulation 
requirements in accordance with Annex NAB and 
3.6.1.
 
Supplied from a.c. mains. 
 
 
 
<12007721 001> 
 
 
Page 82 of 102 
 
National Differences 
Clause 
Requirement 
 Test 
Result – Remark 
Verdict 
 
Chinese National Differences according to CB Bulletin No. 105A, May 2003 
 
APPENDIX  Chinese National Differences according to CB Bulletin No. 105A, May 2003 
(IEC Publication 60950:1999) 
EXPLANATION FOR ABBREVIATIONS 
P=Pass, F=Fail, N=Not applicable.  Placed in the column to the right. 
Supply tolerance 
Item 1.4.5 of IEC 60950 stipulates the tolerance 
of rated voltage is +6% and -10%, while GB4943-
2001 makes a specification of tolerance of +10% 
and -10%. 
Considered, see IEC 60950 
report. 
Power rating marking 
Item 1.7.1 of IEC 60950 does not specify 
concrete figures for supply voltage and 
frequency, instead, descriptions are given by 
examples. But the examples do not include 
China's main voltage. GB4943-2001 stipulates 
that: 
- A single rated voltage shall be expressed as 
220 V 
- When a rated voltage range is given, the range 
shall cover 220 V 
- When a variety of rated voltages or rated 
voltage ranges are given, one of them shall be 
220 V, and shall be set as 220 V when 
dispatched from the factory 
- Rated frequency or rated frequency range shall 
be 50 Hz or include 50 Hz 
If a unit is not provided with a means for direct 
connection to the AC mains supply, it need not be 
marked with any electrical rating 
See copy of marking plate. 
Plate and warning marking in Chinese 
Item 1.7.12 of GB4943-2001 stipulates: 
instructions and equipment markings related to 
safety shall be in standardized Chinese. 
Shall be evaluated when 
submitted for national 
approval. 
Power supply plug 
According to China's particular standards for 
power supply plug, it is added in article 3.2.1 of 
GB4943-2001 that plug connecting equipment 
with AC mains supply shall be in accordance with 
requirements of GB1002. 
No plug provided. 
Page of 115
Display