Harman Kardon DVD 30 (serv.man2) EMC - CB Certificate ▷ View online
page 12 of 32
Ref.No.:305959-1
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
N
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices resettable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
F1 P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : T1AL250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... : No
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
Tools are required.
P
14.5.3
PTC-S thermistors comply with IEC 60738
N
PTC-S devices (15 W) category FV 1 or better
N
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N
page 13 of 32
Ref.No.:305959-1
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.6
Switches
(See appended table)
14.6.1 Permanently
connected
equipment provided with
an all-pole mains switch unless 5.4.2 is met
N
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
Yes
P
Switch readily accessible and not in mains cord
P
Exception for automatic switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
Display is illuminated.
P
Indication by marking meets Cl. 5
N
Indication of the OFF position
OFF
P
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................. :
fitted, is there a Stand-by mode ............................. :
Yes
P
Stand-by mode clearly discernible ......................... : Illumination P
Exception for low Stand-by current < 0.7 mA
(peak)
(peak)
N
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
1C1 P
14.6.6
Manually operated mechanical switches (MOMS)
separately approved to IEC 61058-1
separately approved to IEC 61058-1
Peak surge current: 43A
P
Manually operated mechanical switch (MOMS)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
Voltage setting device not likely to be changed
accidentally
accidentally
N
page 14 of 32
Ref.No.:305959-1
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.9
Motors (Low voltage DC-motor)
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric
strength
test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
N
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
14.11
Optocouplers
Optocouplers comply with Cl. 8
P
Internal and external dimensions to 13.1.1
P
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
(See critical components.)
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N
15.1.3
Output terminals of AC adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
N
15.2
Provision for protective earthing
Accessible conductive parts of Class
Ι equipment
reliably connected to earth terminal, within
equipment
equipment
N
page 15 of 32
Ref.No.:305959-1
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Class
Ι supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
earth
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance (
Ω) ≤ 0.1 Ω at 25 A ..................... : N
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N
15.3.2
Reliable connection of non-detachable cords:
not soldered to conductors of a printed circuit
board
board
No P
adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
P
wire secured by additional means to the conductor Mating locking connector.
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
P
15.3.6
Terminals to 15.3.3 have sizes required by Table 8
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N
Click on the first or last page to see other DVD 30 (serv.man2) service manuals if exist.