page 8 of 32 
Ref.No.:305959-1  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
10 
INSULATION REQUIREMENTS  
 
 
(See appended table) 
 
10.1 
Insulation resistance (M
Ω) at least 2 MΩ min. after 
surge test for basic and 4 M
Ω min. for reinforced 
insulation 
> 100 M
Ω 
10.2 
Humidity treatment 48 h or 120 h 
48 h (See also Appendix 1) 
10.3 
Insulation resistance and dielectric strength 
 
 
11 
FAULT CONDITIONS  
    (See 
appended 
table) 
 
11.1 
No shock hazard under fault conditions 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 P 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of Table 2 by max. 100 K for 
max. 5 min 
 N 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of Table 2 by not 
more than 100 K for an area not greater than 
2 cm
2
 
 N 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm
2
 for a maximum of 5 min 
 N 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 N 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of other parts not subject to the 
limits of 11.2.1 to 11.2.5 
 P 
 
 
 
page 9 of 32 
Ref.No.:305959-1  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 Bump 
test 
<7 
kg 
12.1.2 
Vibration test 
No connection or part, which 
might impair safety, can 
become loose. 
12.1.3 Impact 
test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
12.5 
Antenna coaxial sockets providing isolation 
 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
 
13.1 
Clearances and creepage distances in accordance 
with 13.2 (fig. 9); minimum distance  ...................... :
Prim. – sec.= 6.2mm 
Prim. – Accessible parts= 6.2 mm 
13.1.1 
Reduction applied if the 3 conditions are met  ....... : No 
 
Reduction applied for Grade 2 winding wire .......... : No 
13.1.2 
Use of cemented joints ........................................... : No N 
 
Tests to confirm cemented joints 
 
13.2 
Clearances and creepage distances of parts of 
different polarity connected to the mains, as in 
fig. 9; minimum distance  ........................................ :
 
 
3.1 mm 
 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N 
13.3 
Enclosed, enveloped or hermetically sealed parts: 
clearances and creepage distances to Table 4 
 N 
13.4 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N 
13.5 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N 
 
 
 
page 10 of 32 
Ref.No.:305959-1  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14 COMPONENTS 
 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N 
 
a) Resistors separately approved .......................... :  
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N 
 
b) Resistors separately approved .......................... :  
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
Yes  
14.2.1 
Y capacitors tested to IEC 60384-14, 2:nd Edition  : Y1: C3, C4, C5, C7 
14.2.2 
X capacitors tested to IEC 60384-14, 2:nd Edition  : X2: C1, C2    X1: 1C1 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
 N 
14.2.5 
Capacitors with volume exceeding 1750 mm
3
 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better ....................................................................... :
 N 
 
Capacitors with volume exceeding 1750 mm
3
mounted closer to a potential ignition source than 
Table 5 permits: compliance with IEC 60384-1, 
4.38 category B or better ........................................ :
 N 
 
Shielded by a barrier to FV 0 or metal ................... :  
14.3 
Inductors and windings 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type .............................. :
Power transformer TR1:  
BCK-ER2803  HK3 
 
Transformers and inductors separately approved  : No 
14.3.2 
Isolating transformer complies with 14.3.3, 
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.3, 14.3.4.1, 14.3.5.1 
 
Separating transformer complies with 14.3.3, 
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
 N 
 
Flammability test of insulating material acc. to 
20.1.4 (except in thin sheet form) 
Bobbin. P 
14.3.3.1 
Clearances and creepage distances according to 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
 
 
page 11 of 32 
Ref.No.:305959-1  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14.3.4.1 
Class 
ΙΙ transformers have adequate separation 
between hazardous live windings and accessible 
windings (double or reinforced insulation) 
TR1  
Prim. – sec.= 6.1 mm  
 
Coil formers and partition walls 
≥ 0.4 mm 
 P 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
Iron core in TR1 not connected 
to acc. parts. 
 
Coil formers and partition walls 
≥ 0.4 mm 
 P 
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N 
 
Component meets category FV 1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
 P 