DOWNLOAD Harman Kardon DPR 2005 Service Manual ↓ Size: 2.79 MB | Pages: 53 in PDF or view online for FREE

Model
DPR 2005
Pages
53
Size
2.79 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dpr-2005.pdf
Date

Harman Kardon DPR 2005 EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 41 of 41 - 
 
 
   
 Order 
No. 
24776
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Top cover 
opening 
Blocked 253 
hr 
28 min 
F101
 
1,32 A 
Components are heated-up to (
∆t);
- T101 coil 
: 68K 
- T101 core 
: 65K 
- T102 coil 
: 51K 
- T102 core 
: 52K 
- T103 coil  
: 55K 
- T201 coil 
: 48K 
- T201 core 
: 49K 
- T202 coil 
: 49K 
- T202 core 
: 48K 
- LF101 coil 
: 36K 
- LF102 coil 
: 35K 
and unit shut down after 1 hr. 28 min. 
Input current stabilised at 0,17 A. 
Dielectric strength test O.K. 
No hazard
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998  -
 
- Page 1 of 3 - 
 
 
   
 Order 
No. 
24776
 
 
APPENDIX  
CENELEC EN 60065:1998 
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL 
DEVIATIONS AND OTHER INFORMATION   
P
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
 
DE = Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = 
Sweden. 
P = Pass, F = Fail, = Not applicable.
 
1.1.1 C 
Replace text in Note 1 by : This 
standard can be used as a guide for 
the testing of battery operated 
apparatus.  
 
2.6.1 S 
(DK)  Class I apparatus provided 
with a plug not establishing earthing 
continuity when inserted in Danish 
socket-outlets, see 15.1.1. 
 
Class II apparatus 
3.1 C 
Delete the note. Add the following 
indent : exposure to excessive sound 
pressures from headphones or 
earphones. 
 
 
 
D 
(DE) Marking in case of intrinsically 
ionizing radiation, cathode-ray tubes 
 
D 
(IT) Marking and instruction 
requirements  
- power consumption (W) for TV 
receivers  
 
6.1 D 
(DE) Limits for ionizing radiation, TV 
receivers (max. 1
µSv/h) 
 
15.1.1 C 
Delete notes 1 and 2. 
Add to note 4: Attention is drawn to 
the fact that a standard is under 
preparation (presently prEN 50074) 
for socket-outlets which allow 
connection of Class II appliances 
only.  
 
15.1.1 S 
(DK) Mains plug according to Heavy 
Current Regulations, Section 107-2-
D1 
(DK) Mains socket outlets Cl.I 
(DK) Mains socket outlets Cl.II 
Not supplied with a cord set, See summary of testing. 
15.1.1 S 
(IE) Mains plug, flexible cord, 
according to statutory Instrument 
525: 1997 
Not supplied with a cord set, See summary of testing. 
15.1.1 S 
(NO) Mains socket outlets CI.II 
 
15.1.1 S 
(GB) Mains plug, flexible cord, 
according to statutory Instrument 
1768: 1994 
Not supplied with a cord set, See summary of testing. 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998  -
 
- Page 2 of 3 - 
 
 
   
 Order 
No. 
24776
 
 
 
15.2 C 
Delete note 2
 
 
 
16.1 C 
Delete note 1
 
 
 
16.2 C 
Delete the note 
 
 
 
20 C 
Delete note 2
 
 
 
 
APPENDIX 
ANNEX B (normative) 
 
No TNV 
Annex B C 
Delete note 2 
 
 
B.5.4.1  S 
(NO) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
Applicable text is: 
"Apparatet må kun tilkoples jordet 
stikkontakt" or  
"Jordet stikkontakt skal benyttes når 
apparatet tilkoples datanett" 
Swedish text can also be accepted. 
 
 
B.5.4.1  S 
(SE) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
The marking text shall be in Swedish 
and as follows: 
"Apparaten skall anslutas till jordat 
uttag när den ansluts till ett nätverk"  
 
 
B.5.4.1 e) 
C 
Delete notes 1 and 2 
 
 
B.8.1 C 
Delete notes 1, 2 and 3 
 
 
B.8.1 S 
(DK) Method b) is permitted only for 
PERMANENTLY CONNECTED 
APPARATUS 
 
 
B.8.1 S 
(NO) Method b) is not permitted 
 
 
B.8.2 C 
Delete the note 
 
 
B.14.12 C 
Delete notes 1 and 2 
 
 
B.14.12 S 
(DK) The following note is added: 
NOTE in Denmark the use of surge 
suppressors between the 
TELECOMMUNICATION 
NETWORK and conductive 
ACCESSIBLE parts or TERMINALS 
which are considered to be 
ACCESSIBLE, is allowed only for 
PERMANENTLY CONNECTED 
APPARATUS. 
 
 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998  -
 
- Page 3 of 3 - 
 
 
   
 Order 
No. 
24776
 
 
 
B.14.12 S 
(NO) The following note is added: 
NOTE in Norway, for Class I 
apparatus intended to be connected 
to the MAINS by means of a plug, 
surge suppressors may only be 
connected between TNV circuits and 
ACCESSIBLE parts if the apparatus 
has a marking stating that it must be 
connected to an earthed MAINS 
socket outlet. 
 
 
B.14.12 S 
(SE) The following note is added: 
NOTE in Sweden, for Class I 
apparatus intended to be connected 
to the MAINS by means of a plug, 
surge suppressors may only be 
connected between TNV circuits and 
ACCESSIBLE parts if the apparatus 
has a marking stating that it must be 
connected to an earthed MAINS 
socket outlet. 
The marking text shall be in Swedish 
and as follows: 
"Apparaten skall anslutas till jordat 
uttag." 
 
 
APPENDIX 
ANNEX G (normative) 
 
 
 
Annex G C 
Delete the note 
 
 
APPENDIX 
ANNEX P (informative) 
 
 
 
Annex P C 
Add the following notes for the 
standards indicated : 
IEC 60130 : 
NOTE: IEC 60130-9:1989 + A1:1993 
are harmonized as EN 60130-9 (not 
modified). 
IEC 60169 : 
NOTE: Parts 23, 24 and 25 are 
harmonized as Ens (not modified). 
IEC 60173 :  
NOTE: Harmonized as HD 27 
S1:1983 (not modified). 
IEC 60260 :  
NOTE: Harmonized as HD 98 
S1:1977 (not modified). 
IEC 60335-2-56 : 
NOTE: Harmonized as EN 60335-2-
56: 1997 (not modified). 
IEC 61040 : 
NOTE: Harmonized as EN 61040: 
1992 (not modified). 
IEC 60695 : 
NOTE: Harmonized as EN 60695 
series (not modified). 
 
 
 
 
Page of 53