IEC 60065, 6th edition : 1998
 - 
- Page 37 of 41 - 
 
 
   
 Order 
No. 
24776
 
 
 
 
FAULT CONDITION TESTS  
P
Ambient temperature  
 25,5 °C 
Rated voltage  
230V~ 
Remarks  
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
BD101 
S-c 
253 
AC - (+) 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
BD101 
S-c 
207 
AC - (+) 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C106 
S-c 
253 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C106 
S-c 
207 
14 sec. 
F101 
3,60 A 
F101 opened After 14 sec. 
C107 damaged. 
No hazard. 
C107 
S-c 
253 
1 sec. 
F101 
F101 opened immediately. 
No hazard. 
C107 
S-c 
207 
17 sec. 
F101 
9,30 A 
F101 opened After 17 sec. 
C106 damaged. 
No hazard. 
Q102 
S-c 
253 
S – D 
1 sec. 
F101 
F101 opened immediately. 
Q103, ZD102 damaged. 
No hazard. 
Q102 
S-c 
253 
D - G 
1 sec. 
F101 
F101 opened immediately. 
Q103, ZD101 damaged. 
No hazard. 
Q105 
S-c 
253 
S – D 
1 sec. 
F101 
F101 opened immediately. 
Q104, ZD104 damaged. 
No hazard. 
Q105 
S-c 
253 
D - G 
1 sec. 
F101 
F101 opened immediately. 
Q104 damaged. 
No hazard. 
U101 
S-c 
253 
Pin 2 - 4 
1 sec 
F101 
F101 opened immediately. 
U101, ZD105 damaged. 
No hazard. 
C108 
S-c 
253 
30 min 
F101 
1,40 A 
Normal operated. 
Input current stabilised at 1,20A. 
Q1, Q2 damaged. 
R123 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 41 - 
 
 
   
 Order 
No. 
24776
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
BD202 
S-c 
253 
AC – (+) 
30 min 
F101 
0,23 A 
Output signal off immediately. 
T101 primary winding heated up to
118K and thermal fuse opened 
after 14 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
C218 
S-c 
253 
40 min 
F101 
1,53 A 
T101 primary winding heated up to
120K and thermal fuse opened 
after 21 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
BD201 
S-c 
253 
AC – (+) 
30 min 
F101 
1,52 A 
T101 primary winding heated up to
121K and thermal fuse opened 
after 19 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
C220 
S-c 
253 
40 min 
F101 
0,19 A 
T101 primary winding heated up to
116K and thermal fuse opened 
after 25 min. 
Input current stabilised at 0,20 A. 
Dielectric strength test OK. 
No hazard. 
D206 
S-c 
253 
A - C 
50 min 
F101 
2,10 A 
Unit shut down after 25 min. 
Input current stabilised at 0,20 A. 
D206, T102 damaged and 
C210, C220, C211 vented. 
Dielectric strength test OK. 
No hazard. 
C216 
S-c 
253 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
D207 
S-c 
253 
A - C 
10 min 
F101 
2,00 A 
Unit shut down after 4 min. 
Input current stabilised at 0,20 A. 
T102 damaged. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 39 of 41 - 
 
 
   
 Order 
No. 
24776
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C210 
S-c 
253 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
D204 
S-c 
253 
A - C 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
C207 
S-c 
253 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
D214 
S-c 
253 
A - C 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
C222 
S-c 
253 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
D217 
S-c 
253 
A - C 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
D216 damaged. 
No hazard. 
C225 
S-c 
253 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
D216, D217 damaged. 
No hazard. 
D218 
S-c 
253 
AC – (+) 
1 hr 
20 min 
F101 
1,45 A 
Normal operated. 
Input current stabilised at 1,44A. 
No component damaged. 
No hazard. 
C229 
S-c 
253 
1 hr 
F101 
1,50 A 
Normal operated. 
Input current stabilised at 1,45A. 
No component damaged. 
No hazard. 
Q203 
S-c 
253 
E - B 
40 min 
F101 
1,48 A 
Normal operated. 
Input current stabilised at 1,45A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 40 of 41 - 
 
 
   
 Order 
No. 
24776
 
 
 
 
FAULT CONDITION TESTS (Continued) 
P
Comp. 
No 
Fault Test 
Point Test 
time 
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Q203 
S-c 
253 
E - C 
2 hr 
F101 
0,84 A 
Output signal off after 3 sec. 
Input current stabilised at 0,43A. 
R223 opened. 
No hazard. 
Q204 
S-c 
253 
E - C 
40 min 
F101 
1,71 A 
Output signal off after 2 sec. 
Input current stabilised at 0,45A. 
R223 opened. 
No hazard. 
Q204 
S-c 
253 
E - B 
30 min 
F101 
1,47 A 
Normal operated. 
Input current stabilised at 1,45A. 
No component damaged. 
No hazard. 
PC102 
S-c 
253 
Pin 3 - 4 
(Pri. side)
 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
PC102 
S-c 
253 
Pin 1 - 2 
(Sec. side)
 
10 min 
F101 
0,21 A 
Unit shut down immediately. 
Input current stabilised at 0,21 A. 
No component damaged. 
No hazard. 
PC101 
S-c 
253 
Pin 3 - 4 
(Pri. side)
 
30 min 
F101 
1,49 A 
Normal operated. 
Input current stabilised at 1,49A. 
No component damaged. 
No hazard. 
PC101 
S-c 
253 
Pin 1 - 2 
(Sec. side)
 
10 min 
F101 
0,20 A 
Unit shut down immediately. 
Input current stabilised at 0,20 A. 
No component damaged. 
No hazard. 
AMP 
module 
installed 
FAN 
Locked 253 
20 
min  F101
 
1,33 A 
Protection circuit in AMP module 
operated after 19 min. 
Input current stabilised at 0,16 A. 
No component damaged. 
No hazard.
 
Front 
speaker 
terminal 
S-c 
253 
R - G 
10 min 
F101
 
1,33 A 
Unit shut down immediately. 
Input current stabilised at 0,16 A. 
No component damaged. 
No hazard.
 
Pmax. 
opening 
- 253 
- 7 
min 
F101
 
6,18 A 
Unit shut down after 7 min. 
Input current stabilised at 0,16 A. 
No component damaged. 
No hazard.
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
Page of 53