Harman Kardon DPR 2005 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 41 -
Order
No.
24776
FAULT CONDITION TESTS
P
Ambient temperature
25,5 °C
Rated voltage
230V~
Remarks
-
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
BD101
S-c
253
AC - (+)
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
BD101
S-c
207
AC - (+)
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
C106
S-c
253
-
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
C106
S-c
207
-
14 sec.
F101
3,60 A
F101 opened After 14 sec.
C107 damaged.
No hazard.
C107 damaged.
No hazard.
C107
S-c
253
-
1 sec.
F101
-
F101 opened immediately.
No hazard.
No hazard.
C107
S-c
207
-
17 sec.
F101
9,30 A
F101 opened After 17 sec.
C106 damaged.
No hazard.
C106 damaged.
No hazard.
Q102
S-c
253
S – D
1 sec.
F101
-
F101 opened immediately.
Q103, ZD102 damaged.
No hazard.
Q103, ZD102 damaged.
No hazard.
Q102
S-c
253
D - G
1 sec.
F101
-
F101 opened immediately.
Q103, ZD101 damaged.
No hazard.
Q103, ZD101 damaged.
No hazard.
Q105
S-c
253
S – D
1 sec.
F101
-
F101 opened immediately.
Q104, ZD104 damaged.
No hazard.
Q104, ZD104 damaged.
No hazard.
Q105
S-c
253
D - G
1 sec.
F101
-
F101 opened immediately.
Q104 damaged.
No hazard.
Q104 damaged.
No hazard.
U101
S-c
253
Pin 2 - 4
1 sec
F101
-
F101 opened immediately.
U101, ZD105 damaged.
No hazard.
U101, ZD105 damaged.
No hazard.
C108
S-c
253
-
30 min
F101
1,40 A
Normal operated.
Input current stabilised at 1,20A.
Q1, Q2 damaged.
R123 opened.
No hazard.
Input current stabilised at 1,20A.
Q1, Q2 damaged.
R123 opened.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 38 of 41 -
Order
No.
24776
FAULT CONDITION TESTS (Continued)
P
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
BD202
S-c
253
AC – (+)
30 min
F101
0,23 A
Output signal off immediately.
T101 primary winding heated up to
118K and thermal fuse opened
after 14 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
T101 primary winding heated up to
118K and thermal fuse opened
after 14 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
C218
S-c
253
-
40 min
F101
1,53 A
T101 primary winding heated up to
120K and thermal fuse opened
after 21 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
120K and thermal fuse opened
after 21 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
BD201
S-c
253
AC – (+)
30 min
F101
1,52 A
T101 primary winding heated up to
121K and thermal fuse opened
after 19 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
121K and thermal fuse opened
after 19 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
C220
S-c
253
-
40 min
F101
0,19 A
T101 primary winding heated up to
116K and thermal fuse opened
after 25 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
116K and thermal fuse opened
after 25 min.
Input current stabilised at 0,20 A.
Dielectric strength test OK.
No hazard.
D206
S-c
253
A - C
50 min
F101
2,10 A
Unit shut down after 25 min.
Input current stabilised at 0,20 A.
D206, T102 damaged and
C210, C220, C211 vented.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,20 A.
D206, T102 damaged and
C210, C220, C211 vented.
Dielectric strength test OK.
No hazard.
C216
S-c
253
-
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
D207
S-c
253
A - C
10 min
F101
2,00 A
Unit shut down after 4 min.
Input current stabilised at 0,20 A.
T102 damaged.
Dielectric strength test OK.
No hazard.
Input current stabilised at 0,20 A.
T102 damaged.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 39 of 41 -
Order
No.
24776
FAULT CONDITION TESTS (Continued)
P
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
C210
S-c
253
-
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
D204
S-c
253
A - C
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
C207
S-c
253
-
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
D214
S-c
253
A - C
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
C222
S-c
253
-
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
D217
S-c
253
A - C
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
D216 damaged.
No hazard.
Input current stabilised at 0,20 A.
D216 damaged.
No hazard.
C225
S-c
253
-
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
D216, D217 damaged.
No hazard.
Input current stabilised at 0,20 A.
D216, D217 damaged.
No hazard.
D218
S-c
253
AC – (+)
1 hr
20 min
20 min
F101
1,45 A
Normal operated.
Input current stabilised at 1,44A.
No component damaged.
No hazard.
Input current stabilised at 1,44A.
No component damaged.
No hazard.
C229
S-c
253
-
1 hr
F101
1,50 A
Normal operated.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
Q203
S-c
253
E - B
40 min
F101
1,48 A
Normal operated.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 40 of 41 -
Order
No.
24776
FAULT CONDITION TESTS (Continued)
P
Comp.
No
No
Fault Test
V
Point Test
time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
Q203
S-c
253
E - C
2 hr
F101
0,84 A
Output signal off after 3 sec.
Input current stabilised at 0,43A.
R223 opened.
No hazard.
Input current stabilised at 0,43A.
R223 opened.
No hazard.
Q204
S-c
253
E - C
40 min
F101
1,71 A
Output signal off after 2 sec.
Input current stabilised at 0,45A.
R223 opened.
No hazard.
Input current stabilised at 0,45A.
R223 opened.
No hazard.
Q204
S-c
253
E - B
30 min
F101
1,47 A
Normal operated.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
Input current stabilised at 1,45A.
No component damaged.
No hazard.
PC102
S-c
253
Pin 3 - 4
(Pri. side)
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
PC102
S-c
253
Pin 1 - 2
(Sec. side)
10 min
F101
0,21 A
Unit shut down immediately.
Input current stabilised at 0,21 A.
No component damaged.
No hazard.
Input current stabilised at 0,21 A.
No component damaged.
No hazard.
PC101
S-c
253
Pin 3 - 4
(Pri. side)
30 min
F101
1,49 A
Normal operated.
Input current stabilised at 1,49A.
No component damaged.
No hazard.
Input current stabilised at 1,49A.
No component damaged.
No hazard.
PC101
S-c
253
Pin 1 - 2
(Sec. side)
10 min
F101
0,20 A
Unit shut down immediately.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
Input current stabilised at 0,20 A.
No component damaged.
No hazard.
AMP
module
installed
module
installed
FAN
Locked 253
-
20
min F101
1,33 A
Protection circuit in AMP module
operated after 19 min.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
operated after 19 min.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
Front
speaker
terminal
speaker
terminal
S-c
253
R - G
10 min
F101
1,33 A
Unit shut down immediately.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
Pmax.
opening
- 253
- 7
min
F101
6,18 A
Unit shut down after 7 min.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
Input current stabilised at 0,16 A.
No component damaged.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection