Harman Kardon DPR 2005 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 17 of 41 -
Order
No.
24776
a) Temperature rise of printed circuit
boards (PCB) to 20.1.3, exceeding
the limits of Table 2 by not more
than 100 K for an area not greater
than 2 cm²
boards (PCB) to 20.1.3, exceeding
the limits of Table 2 by not more
than 100 K for an area not greater
than 2 cm²
N
b) Temperature rise of printed circuit
boards (PCB) to 20.1.3 up to 300 K
for an area not greater than 2 cm²
for a maximum of 5 min
boards (PCB) to 20.1.3 up to 300 K
for an area not greater than 2 cm²
for a maximum of 5 min
N
Meets all the special conditions if
conductors on printed circuit boards
are interrupted
conductors on printed circuit boards
are interrupted
No conductors are interrupted/peeled/loosened during
fault conditions
fault conditions
N
11.2.4
Temperature rise of parts acting as
a support or mechanical barrier
a support or mechanical barrier
Temperature rises are within the limits.
N
11.2.5
Temperature rise of windings
See Fault Condition tests
P
11.2.6
Temperature rise of parts not
subject to the limits of 11.2.1 to
11.2.5, table 2 item e).
subject to the limits of 11.2.1 to
11.2.5, table 2 item e).
No excessive temperature observed/measured on other
parts.
parts.
P
12
MECHANICAL STRENGTH
P
12.1.1 Bump
test
(>7kg)
No damage in the sense of this standard
P
12.1.2
Vibration test (portable, musical
amplifiers, metal enclosure)
amplifiers, metal enclosure)
Assessed to be satisfactory constructed.
N
12.1.3
Impact test (0.5J)
No damage in the sense of this standard
P
12.2
Fixing of knobs, push buttons, keys
and levers
and levers
Normal use will not impair the protection against electric
shock.
shock.
P
12.3
Remote controls with hazardous live
parts
parts
No remote control containing hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N
12.5
Antenna coaxial sockets providing
isolation
isolation
No antenna socket which insolate hazardous live parts
from accessible parts.
from accessible parts.
N
13
CLEARANCES AND CREEPAGE
DISTANCES
DISTANCES
P
13.1.1
Clearances and creepage distances
in accordance with 13.2 (fig. 9);
minimum distance
in accordance with 13.2 (fig. 9);
minimum distance
See 13.2
P
Reduction applied if the 3 conditions
are met
are met
No reduction applied
N
Reduction applied for Grade 2
winding wire
winding wire
No
N
13.1.2
Use of cemented joints
No cemented joints
N
Tests to confirm cemented joints
N
-
IEC 60065, 6th edition : 1998
-
- Page 18 of 41 -
Order
No.
24776
13.2
Class I apparatus
Class II apparatus
N
Creepage distances and
clearances between live parts and
safety earthed parts (basic
insulation)
clearances between live parts and
safety earthed parts (basic
insulation)
N
Creepage distances and
clearances between live parts and
not safety earthed accessible parts
(reinforced or double insulation)
clearances between live parts and
not safety earthed accessible parts
(reinforced or double insulation)
N
Class II apparatus
P
Creepage distances and
clearances between live parts and
not accessible parts (basic
insulation)
clearances between live parts and
not accessible parts (basic
insulation)
Measured minimum distances:
6,4 mm (reactor, PT01 insulation between W1 and W2).
6,4 mm (reactor, PT01 insulation between W1 and W2).
P
Creepage distances and
clearances between not accessible
parts and accessible parts
(supplementary insulation)
clearances between not accessible
parts and accessible parts
(supplementary insulation)
N
Creepage distances and
clearances between live parts and
accessible parts (reinforced or
double insulation)
clearances between live parts and
accessible parts (reinforced or
double insulation)
Measured minimum distances:
- 6,0 mm (pr - sec)
- 6,5 mm (pr - accessible parts)
- 6,0 mm (pr - sec)
- 6,5 mm (pr - accessible parts)
P
Creepage distances and
clearances measured whilst forces
of 2N and 30N are applied
clearances measured whilst forces
of 2N and 30N are applied
No reduction of clearance/creepage distances when 2N
is applied on internal parts and 30N at the enclosure.
is applied on internal parts and 30N at the enclosure.
P
Clearances and creepage
distances of parts of different
polarity directly connected to the
mains, as in fig. 9; minimum
distance
distances of parts of different
polarity directly connected to the
mains, as in fig. 9; minimum
distance
Measured minimum distances: 3,0 mm
P
Clearances and creepage
distances between conductors on
printed circuit boards, one of which
may be conductively connected to
the mains, as in fig. 10 (overheating
only)
distances between conductors on
printed circuit boards, one of which
may be conductively connected to
the mains, as in fig. 10 (overheating
only)
No overheating of conductors on PWB.
P
13.3
Enclosed, enveloped or hermetically
sealed parts: clearances and
creepage distances to Table 4
sealed parts: clearances and
creepage distances to Table 4
No such parts in the apparatus
N
13.4
Parts filled with insulating
compound, meeting the
requirements of 8.8
compound, meeting the
requirements of 8.8
No components or subassemblies filled with compound.
N
13.5
Type B coated printed circuit boards
complying with IEC 60 664-3 (basic
insulation only)
complying with IEC 60 664-3 (basic
insulation only)
No type B coated PWB
N
-
IEC 60065, 6th edition : 1998
-
- Page 19 of 41 -
Order
No.
24776
14 COMPONENTS
P
14.1 Resistors
N
a) Resistors between hazardous
live parts and accessible metal
parts, or bridging contact gaps on
mains switch.
live parts and accessible metal
parts, or bridging contact gaps on
mains switch.
N
b) Resistors, other than between
hazardous live parts and accessible
parts
hazardous live parts and accessible
parts
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 384-14,
2nd edition
2nd edition
C104, C105, C119, C127, C128 are Y capacitors,
Certified according to IEC 384-14, 2nd edition.
Certified according to IEC 384-14, 2nd edition.
P
14.2.2
X capacitors tested to IEC 384-14,
2nd edition
2nd edition
C101, C102, C103, C403 are X capacitors,
Certified according to IEC 384-14, 2nd edition.
Certified according to IEC 384-14, 2nd edition.
P
Part No
Manufacturer
Value
Type
Marking
Approved by
C101, C103
Pilkor Electronics
1,0 uF 275V
PCX2 335M
1uM, X2
VDE
C102
Pilkor Electronics
0,47 uF 275V
PCX2 335M
470nM, X2
VDE
C104, C105, C119
Netron Tech.
1000pF 250V
AD
102M, X1/Y1
VDE
C127, C128
Netron Tech.
470pF 250V
AD
471M, X1/Y1
VDE
C403
Netron Tech.
4700pF 250V
AA
472M, X1/Y2
VDE
14.2.3
Capacitors operating at mains
frequency but not connected to the
mains: tests for X2
frequency but not connected to the
mains: tests for X2
No such capacitor
N
14.2.5
Capacitors with volume exceeding
1750 mm³, where short-circuit
current exceeds 0,2 A: compliance
with IEC 60 384-1, 4.38 category B
or better
1750 mm³, where short-circuit
current exceeds 0,2 A: compliance
with IEC 60 384-1, 4.38 category B
or better
Cap, volume exceeding 1750 mm
³;
a) X-cap.: C101, C102, C103
b) Several E. cap.
c) Polyester film cap.: C121,
Accepted due to below,
a) Certified according to IEC384-14, 2nd ed.
b) Metal cases.
c) Complies with IEC60384-1, 4.38, to category B.
b) Several E. cap.
c) Polyester film cap.: C121,
Accepted due to below,
a) Certified according to IEC384-14, 2nd ed.
b) Metal cases.
c) Complies with IEC60384-1, 4.38, to category B.
P
Capacitors with volume exceeding
1750 mm³, mounted closer to a
potential ignition source than
Table 5 permits: compliance with
IEC 60 384-1, 4.38 category B or
better
1750 mm³, mounted closer to a
potential ignition source than
Table 5 permits: compliance with
IEC 60 384-1, 4.38 category B or
better
Cap, volume exceeding 1750 mm
³;
a) X-cap.: C101, C102, C103
b) Several E. cap.
c) Polyester film cap.: C121,
Accepted due to below,
a) Certified according to IEC384-14, 2nd ed.
b) Metal cases.
c) Complies with IEC60384-1, 4.38, to category B.
b) Several E. cap.
c) Polyester film cap.: C121,
Accepted due to below,
a) Certified according to IEC384-14, 2nd ed.
b) Metal cases.
c) Complies with IEC60384-1, 4.38, to category B.
P
-
IEC 60065, 6th edition : 1998
-
- Page 20 of 41 -
Order
No.
24776
Shielded by a barrier to FV 0 or
metal
metal
No barrier required. See above.
N
14.3
Inductors and windings
P
14.3.1
Transformers and inductors marked
with manufacturer's name and type
with manufacturer's name and type
Adequate marking applied
P
14.3.2 Transformer
category
Isolating transformer
P
14.3.3-5 Transformer
construction
See below.
P
14.3.3.2
Transformers meet the
constructional requirements :
constructional requirements :
See below.
P
Transformer/motor Insulation
Insulation Test
Flashover Creepage
distances
Part No/markings
Between
Resistance
Voltage
Breakdown
and clearances
M Ohm
KV(60)s
voltage kV
Measured
Required
T101
/ TPW-4102
Pr- sec
> 100
3KV (rms)
-
7,9 mm
≥ 6 mm
Pr- ic
> 100
3KV (rms)
6,5 mm
≥ 6 mm
T102
/ KJP-10013T2 **)
Pr- sec
> 100
3KV (rms)
-
6,0 mm
≥ 6 mm
T103
/ KJP-10013T1 **)
Pr - sec
> 100
3KV (rms)
-
6,0 mm
≥ 6 mm
T201, T202
/ KJP-10013T3 *)
Pr - sec
> 100
3KV (rms)
-
6,0 mm
≥ 6 mm
PT02
/ RE-2500 ***)
Pr- pr
> 100
1.5KV (rms)
- 6,4
mm
≥ 6 mm
Pr- ic
> 100
3KV (rms)
6,5 mm
≥ 6 mm
*) Barrier tape provided: Bottom side - 6,0 mm / Top side - 3,0 mm.
**) Top side
: Min. 3,0 mm spacing or 3,0 mm barrier tape provided.
Bottom side : Min. 6,0 mm spacing or 6,0 mm barrier tape provided.
***) Reactor, before mains fuse.
Components / construction
(Transformer: T101)
Windings on single bobbin. The center flange provided
between primary and secondary winding.
Bobbin thickness:> 0,4mm
between primary and secondary winding.
Bobbin thickness:> 0,4mm
P
Components / construction
(Transformer: T102, T103, T201, T202)
Concentric windings on one bobbin. At least 3 layers of
insulation between primary and secondary winding.
Thickness of each layer: 0.025 mm. Voltage test : 3kV.
insulation between primary and secondary winding.
Thickness of each layer: 0.025 mm. Voltage test : 3kV.
P
Components / construction
(Reactor: PT02)
Windings on single bobbin. The center flange provided
between primary W1 and primary W2 windings.
Bobbin thickness:> 0,4mm
between primary W1 and primary W2 windings.
Bobbin thickness:> 0,4mm
P