Harman Kardon DPR 2005 (serv.man3) EMC - CB Certificate ▷ View online
WOORI Technology Inc. Page 6 of 84
DPR2005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 267.EMI
3. General Test Conditions
3.1 Location
NEMKO KOREA Co., Ltd.
300-2, Osan-Ri, Mohyun-Myun, Yongin-City, Kyungki-Do, Koera. 449-852
Phone : +82-31-322-2333 Fax : +82-31-322-2332
3.2 Operating Environment
All tests and measurements were performed in a shielded enclosure or a controlled environment
suitable for the tests conducted. The climatic conditions in the test area are automatically controlled
and recorded continuously.
Parameters Recording
during
test
Accepted deviation
Ambient temperature
20℃
15 - 35℃
Relative humidity
45%
30 - 60%
Atmospheric pressure
100kPa
86-106kPa
3.3 Operating During Test
● The receiver was set to an RF mono signal frequency modulated at 1kHz with 37.5kHz deviation
and set to Tape, DVD, Video 2, Video 4., 8CH Direct with a sinusoidal signal of 1kHz.
The interface cables shall be connected to the available interface ports of the EUT.
3.4 Test Equipment
● The test equipment used in testing are calibrated on a regular basis. For most of the testing
equipment accredited calibration is conducted once a year. For certain equipment the calibration
interval is longer. Between the calibrations all test equipment are controlled and verified on a
regular basis. The test equipments used are defined in each test section of this report.
3.5 Support Equipment
Equipment Model Manufacturer Serial
No.
VP-8174A Mitsubishi 110487b122
Signal Generator
7101 Dagatron 61101076
OS-5060A
LG Precision Co.,Ltd
71200320
Oscilloscope
SS-5710 Iwatsu 61214036
Load 8
ohm RARA
N/A
Notebook CM2080
Compaq 5Y12FP74KC49
Notebook Adapter
PA-1600-02
Lite-Elec.
Printer HP692C
HP
SG74TIC206
Printer Adapter
C2182A
NMB
230597
Keyboard SDM4500P
Samsung
PS/2 Mouse
M-S48
Logitech
LZA75395360
USB Mouse
OMS3CE
Immanual
WOORI Technology Inc. Page 7 of 84
DPR2005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 267.EMI
3.6 Interface Cable
Connection of EUT
Cable Data
RCA Jack
RCA Cable, Shield 1.5m
Speakers Non
Shield
1.0m
S-Video Shield
1.5m
Headphone Shield
2.0m
A-BUS Non
Shield
2.0m
Remote Shield
1.5m
RS-232C Shield
2.0m
4. Evaluation of Performance
4.1 Measurement Uncertainty
Measurement uncertainty is calibrated in accordance with :
●EMCIT document 93/30
●NAMAS Information Sheet NIS81,Ed.1 May 1994
(The treatment of uncertainties in EMC measurement).
The measurement uncertainty is not considered when deciding PASS or FAIL against the limit lines.
This means that “shared risk” (according to NAMAS publication NIS81 4.2) is used as option
Criterion. The argument for using this method, is that it is commonly accepted that the EMC limits
have already taken common good laboratory practice.
4.2 Final Decision
The equipment under test complies to all requirements of the applied test standards.
WOORI Technology Inc. Page 8 of 84
DPR2005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 267.EMI
5. Standards, Deviations And Results
5.1 Applied Test Standards
The following standards have been applied:
●EN 55013:2001:
Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and
Associated equipment
Phenomena Basic
Standards
Result
Mains terminal continuous disturbance voltage
EN 55013: 2001
Pass
Radio Interference Power
EN 55013: 2001
Pass
Radiated Disturbance
EN 55013: 2001
Pass
Antenna Terminal Disturbance Voltage
EN 55013: 2001
Pass
●EN 61000-3-2 :2000 :
Disturbances in supply systems caused by household appliances and similar electrical equipment
Phenomena Basic
Standards
Result
Steady State Harmonics
EN 61000-3-2:2000
N/A
Fluctuating Harmonics
EN 61000-3-2:2000
Pass
●EN 61000-3-3:1995+A1: 2001
Disturbances in supply systems caused by household appliances and similar electrical equipment
Phenomena Basic
Standards
Result
Flicker
EN 61000-3-3:1995+A1: 2001
Pass
Voltage Fluctuations
EN 61000-3-3:1995+A1: 2001
N/A
5.2 Deviations And Evaluations
●No recorded deviations to the applied standards.
●No general evaluations made.
WOORI Technology Inc. Page 9 of 84
DPR2005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 267.EMI
6. Mains Terminal Continuous Disturbance Voltage
6.1 Test Procedure
The measurements were performed in a shielded enclosure. EUT was connected to an Artificial Mains
Network (AMN). EUT was placed on a wooden table 0.8m above the grounded floor and at least 0.4m from
the reference ground plane(wall), EUT was placed at least 0.8m from, and connected via a 1m mains cable,
to the AMN.
The output power of the amplifier was set to 1/8 of rated power at 8ohms load.
The measurements on the terminals for mains connection were conducted between neutral and ground, and
between phase and ground, in the frequency range 150kHz to 30MHz.
A peak detector scan was conducted over the defined frequency range on all phases. A comparison of the
results obtained from the different phases was then conducted to find the most emitting phase for each
frequency. This “Worst Case” scan with peak detector is presented detector.
Instrumentation used during this session:
Instruments Manufacturer
Model
Serial number
Due To Calibration
Test Receiver
R&S
ESCS30 833364/020 2004.
09
Artificial Mains Network
R&S
ESH3-Z5
833874/006
2004. 10
6.2 Measurement Uncertainty
Mains terminal disturbance voltage measurement : ±3.0dB
6.3 Test Parameters
Port:
AC Mains
Test Engineer:
J. Y. Yu
Basic Standard:
EN55013: 2001
Frequency Range:
150kHz – 30MHz
Frequency Step:
5kHz
IF Bandwidth:
9kHz
Measurement Time:
0.2 Sec
6.4 Test Data
1-1) Tuner FM 98.0 MHz 7-CH Stereo Mode (Ground)
Frequency
(MHz)
Q-Peak
Average
Q-Peak
Average
Q-Peak
Average
0.46
32.7
32.3
N
56.7
46.7
24.0
14.4
0.77
33.7
31.7
L1
56.0
46.0
22.3
14.3
3.74
38.3
37.8
N
56.0
46.0
17.7
8.2
4.27
35.1
34.6
N
56.0
46.0
20.9
11.4
9.21
41.9
35.4
N
60.0
50.0
18.1
14.6
17.98
41.8
32.1
L1
60.0
50.0
18.2
17.9
Line
Limit (dB㎶)
Reading Value (dB㎶)
Margin (dB)
Click on the first or last page to see other DPR 2005 (serv.man3) service manuals if exist.