WOORI Technology Inc.                                                Page 20 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
9. Antenna Terminal Disturbance Voltage 
 
9.1 Test Procedure 
       
        Measurements were performed in the frequency range 30 MHz to 1,000 MHz. 
      The level of the test signal, which was connected to the receiver through a power combiner, was set to      
give 70 dBuV at the input of the receiver. The signal was an appropriate unmodulated sound carrier. 
Disturbance voltage due to the local oscillator due to the local oscillator and its fundamental and    
harmonic frequencies was measured with the receiver tuned to a selected number.   
        Instrumentation used during this session: 
 
Instruments 
Manufacturer 
Model 
Serial number 
Due To Calibration
Test Receiver   
Rohde&Schwarz
ESCS30 833364/020 2004. 
09 
Matching Pad 
Rohde&Schwarz
RAM358.5414.02 
893921.029 
2005. 05 
3-point Junction   
Network 
Hewlett Packard
11667A 
18907 
2005. 05 
 
9.2 Measurement Uncertainty
 
         
    Antenna terminal disturbance voltage, quasi-peak detection:                ±3.0dB 
 
9.3 Test Parameters 
 
Port: 
Antenna Terminal 
Test Engineer: 
J. Y. Yu 
Basic Standard: 
EN 55013: 2001 
 
IF Bandwidth: 
120kHz 
Measurement Time: 
0.2Sec 
Frequency Range: 
30MHz – 1GHz 
 
 
 
 
WOORI Technology Inc.                                                Page 21 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
 
9.4 Test Data (Receiving Mode) 
 
T. Freq.*
Frequency
Reading 
MPL **
NPL ***
Result
Limit
Margin
(MHz)
(MHz)
(dB)
(dB)
(dB)
(dB)
(dB)
(dB)
87.5
98.20
9.0
7.5
6.7
23.2
54.0
30.8
196.40
7.5
7.5
7.9
22.9
50.0
27.1
294.60
5.0
7.5
7.4
19.9
50.0
30.1
392.80
5.0
7.5
7.4
19.9
52.0
32.1
491.00
5.0
7.5
7.7
20.2
52.0
31.8
589.20
5.0
7.5
7.4
19.9
52.0
32.1
687.40
14.6
7.5
7.4
29.5
52.0
22.5
785.60
5.0
7.5
8.0
20.5
52.0
31.5
883.80
5.0
7.5
7.6
20.1
52.0
31.9
982.00
5.0
7.5
7.6
20.1
52.0
31.9
98.0
108.70
7.3
7.5
6.8
21.6
54.0
32.4
217.40
6.1
7.5
7.1
20.7
50.0
29.3
326.10
5.0
7.5
7.7
20.2
52.0
31.8
434.80
5.0
7.5
7.6
20.1
52.0
31.9
543.50
5.0
7.5
8.0
20.5
52.0
31.5
652.20
5.0
7.5
8.0
20.5
52.0
31.5
760.90
10.4
7.5
8.0
25.9
52.0
26.1
869.60
11.4
7.5
7.8
26.7
52.0
25.3
978.30
5.0
7.5
7.6
20.1
52.0
31.9
108.0
118.70
11.7
7.5
6.8
26.0
54.0
28.0
237.40
6.4
7.5
7.2
21.1
50.0
28.9
356.10
5.0
7.5
7.6
20.1
52.0
31.9
474.80
5.0
7.5
7.6
20.1
52.0
31.9
593.50
5.0
7.5
7.8
20.3
52.0
31.7
712.20
5.0
7.5
7.7
20.2
52.0
31.8
830.90
27.5
7.5
8.0
43.0
52.0
9.0
949.60
5.0
7.5
7.7
20.2
52.0
31.8
 
 
 
    *)    T. Freq. = Tuned Frequency 
    **)   MPL = Matching Pad Loss 
        ***)    NPL = 3-Point Junction Network Loss   
 
 
 
Comment 
        If no frequencies are specified in the tables, no measurement for quasi-peak was necessary. 
 
       
Result 
    Compliant 
 
 
 
WOORI Technology Inc.                                                Page 22 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
 
9.5 Test Data (Others) 
 
T. Freq.*
Frequency
Reading 
MPL **
NPL ***
Result
Limit
Margin
(MHz)
(MHz)
(dB)
(dB)
(dB)
(dB)
(dB)
(dB)
More than 20dB Margin
 
 
 
    *)    T. Freq. = Tuned Frequency 
    **)   MPL = Matching Pad Loss 
        ***)    NPL = 3-Point Junction Network Loss   
 
 
 
Comment 
        If no frequencies are specified in the tables, no measurement for quasi-peak was necessary. 
 
        Result 
    Compliant 
 
 
 
WOORI Technology Inc.                                                Page 23 of 84 
                               DPR2005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 267.EMI 
 
10. Fluctuating Harmonics (EN 61000-3-2) 
 
10.1 Test Procedure 
         
        EUT was connected to the Power Analyzer system. Measurements were conducted on all active phases, 
for harmonics 1-40th of the mains frequency (50 or 60Hz). A pure AC mains was supplied to the 
system from two power supply units. The units supply an AC mains, free of harmonics or distortion of 
any kind. An overview of the harmonic emission is presented as numerics and as graphics. 
     Instrumentation used during this session: 
 
Instruments Manufacturer 
Due 
To 
Calibration 
Profline 2100 System 
Schaffner 
2004. 09 
 
10.2 Test Parameters
 
 
Port: 
AC Mains 
Test Engineer: 
J. Y. Yu 
Basic Standard: 
EN 61000-3-2:2000 
 
 
 
10.3 Fluctuating Harmonics, Graphic Presentation 
 
        Measurement results can be found in the 
Appendix C
 
       
Result 
       
Compliant  
 
10.4 Remarks 
 
Speaker Output Conditions 
 
Power 
Consumption
Speaker Channel
L
32.04
V
11.35
V
8  ohm
Front
R
32.02
V
11.36
V
8  ohm
Speaker Channel
L
32.12
V
11.37
V
8  ohm
Rear
R
32.08
V
11.36
V
8  ohm
Speaker Center
32.06
V
11.37
V
8  ohm
Speaker Channel
L
32.14
V
11.40
V
8  ohm
Rear Back
R
32.00
V
11.41
V
8  ohm
Speaker 
Pmax. 
Channel
1,090 W
1/8 Pmax. 
210 W
Impedance
 
 
 
 
Page of 85