Harman Kardon DPR 1005 (serv.man14) EMC - CB Certificate ▷ View online
WOORI Technology Inc. Page 4 of 104
DPR 1005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 320.EMS
1. Client Information
1.1 Applicant
1.2 Manufacturer
1.3 Factory
1.4 Other Information
●No Comment
Company Name:
WOORI Technology Inc.
Company Address:
WooriTG. Bldg., 1595-1, Bongcheon-7Dong,
Kwanak-Gu, Seoul, Korea, 151-835
Phone/Fax:
+82-2-2102-5132 / +82-2-886-8560
Contact Name:
Mr. D. S. Cho
Company Name:
WOORI Technology Inc.
Company Address:
WooriTG. Bldg., 1595-1, Bongcheon-7Dong,
Kwanak-Gu, Seoul, Korea, 151-835
Phone/Fax:
+82-2-2102-5132 / +82-2-886-8560
Contact Name:
Mr. D. S. Cho
Company Name:
Guangzhou Telefield Ltd.
Company Address:
No. 1 Industrial Area, Zhuliao, Guangzhou Baiyun Area,
Guangdong Province, P.R. China.
Phone/Fax:
+86-20-8744-0109 (ext 218)/+86-20-8744-0161
Contact Name:
Mr. Dae Young, Rho
WOORI Technology Inc. Page 5 of 104
DPR 1005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 320.EMS
2. Equipment Under Test ( EUT)
2.1 Identification of EUT
Category:
AV Receiver
Model Name:
DPR1005
Brand Name:
Harman Kardon
External Signal in/out:
Audio INOUT (24), 8CH Direct IN (8), Pre-OUT (8),
Digital Coaxial IN/OUT (4), Component Video IN/OUT (3),
S-Video IN/OUT (9), Composite Video IN/OUT (9),
Remote IN/OUT (2), Multi Room (1), RS-232 (1), A-BUS (1),
Antenna FM/AM (2), Speaker (7), Headphone (1)
Serial Number:
N/A
Voltage:
AC 230V, 50Hz
Power:
630 W (Max.), 140W (1/8W)
Remarks:
2.2 Variants Covered By This Report
ID No.
Model Name
Technical Deviations From Reference Model
N/A N/A
2.3 Modifications
●No modifications.
2.4 Additional Information Related To Testing
●No comment
2.5 Picture Documentation
●Pictures can be found in
Appendix F.
WOORI Technology Inc. Page 6 of 104
DPR 1005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 320.EMS
3. TEST SPECIFICATIONS
3.1 Standards
EN55 020(2002) : Electromagnetic immunity of broadcast receivers and associated equipment.
3.2 Additions, deviations and exclusions from standards
No additions, deviations or exclusions have been made from standard.
3.3 Purpose of the test
Purpose of test: To determine whether the equipment under test fulfils the EMC immunity
requirements of the standard stated in section 3.1
3.4 Test site location
ANAM Electronics Co., Ltd.
Nemko korea Co., Ltd.
3.4.1 Location
645, Sungkok-dong, Ansan-City, Kyungki-Do, 425-110, Korea
This test site has been accredited to EMC TBM (EN 55013, EN55020) test site by Nemko.
The AUT. No. is : 357
4. TEST SUMMARY
The results in this report apply only to sample tested :
Test
Passed the test
Note
Input immunity to RF voltages (S1)
Yes
Immunity to RF voltages (S2a)
Yes
Immunity to RF voltages(in common mode) (S2b)
Yes
Immunity to ambient electromagnetic fields (S3)
Yes
Screening effectiveness (S4)
Yes
Test
Passed the test
Electrostatic Discharge (EN 61000-4-2)
Yes
Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test
(EN 61000-4-3)
Yes
Electrical Fast Transients/Burst (EN 61000-4-4)
Yes
The equipment does comply with the requirements
Measurement data see Annex A, B, C, D and E.
WOORI Technology Inc. Page 7 of 104
DPR 1005 (Harman Kardon)
EMC Test Report
Reference No.: NK2EE 320.EMS
5. Input immunity to RF voltages (in Differential mode) (S1)
5.1 Test criteria and test procedure
Operating environment;
Temperature
23 ℃
Relative Humidity
40 %
The criterion concerning acceptable sound interference is a wanted to unwanted
audio signal ratio of ≥40 dB at a wanted signal level of 50 mW.
The EUT was placed 0.1m above a metallic ground plane of dimensions 2 x 1 m.
The measuring set-up was shown in Figure 1 EN55020 (2002).
The principle of operation was similar to the measuring set-up of Figure 1 EN55020 (2002).
The low pass filter was added to prevent influence of the measuring results by
harmonics of the unwanted signal generators.
The lineout of the EUT were applied to an 22k ohm purely resistive road (Ro)
and then to the AF inputs of the test system.
The power supply of the EUT was connected to a standard voltage source
(without special filters).
The measurements were performed with test software TS9980 Ver.2.9.
5.2 Measurement uncertainty
Antenna input immunity +/- 2.0dB
5.3 Test result of input immunity to RF voltages.
The equipment does comply with the requirements.
For the measurement data, see Annex A
Click on the first or last page to see other DPR 1005 (serv.man14) service manuals if exist.