DOWNLOAD Harman Kardon DPR 1005 (serv.man14) Service Manual ↓ Size: 8.82 MB | Pages: 127 in PDF or view online for FREE

Model
DPR 1005 (serv.man14)
Pages
127
Size
8.82 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
dpr-1005-sm14.pdf
Date

Harman Kardon DPR 1005 (serv.man14) EMC - CB Certificate ▷ View online

 
WOORI Technology Inc.                        Page 16 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
12. Fast Transients/Burst (EN 61000-4-4) 
 
12.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
20  ℃ 
 
Relative Humidity: 
40 % 
 
A ground reference plane was located on the floor, and connected to earth via a low impedance connection. 
The EFT/Burst generator's reference ground was connected to the reference plane. In case of a floor 
a floor standing equipment, EUT was placed on the reference plane on 10cm of insulating support. 
In case of table-top equipment, EUT was placed on a wooden table 0.8m above the reference plane. 
Burst were fired at ±1kV to each single line at the AC and DC mains, and ±0.5kV was applied to signal 
cables using a capacitive coupling clamp. 
 
Instrumentation used during this session: 
Instruments 
Manufacturer
Model 
Serial Number  Due to Calibration
 EFT/Burst Simulator 
Noiseken 
FNS-AXⅡ850
0199B01147 
2005. 02 
 Clamp 
Noiseken 
FNS-AXⅡ850
N/A 
2005. 02 
 
12.2 Test Parameters 
    Port :
 
AC Mains
 
 
Test Engineer: 
J. Y. Yu 
  Basic Standard :
 
EN 61000-4-4:1995
 
 
Performance Criteria: 
  Duration :
 
120 Sec
 
±8kV 
 
 
    Test Data :
 
Tr/Th   5/50ms   Fburst   5 kHz    Trep   300mS 
 
12.3  Test Log 
 
Line Voltage 
Coupling 
Inject Time 
( Sec ) 
Result  
(Pass/Fail) 
L1 
0.5, 1 kV 
Direct 
120 
Pass 
L2 
0.5, 1 kV 
Direct 
120 
Pass 
L1+ L2 
0.5, 1 kV 
Direct 
120 
Pass 
 
Comment/Performance 
No operation errors were detected during or after the discharges 
 
Result 
Compliant 
 
WOORI Technology Inc.                        Page 17 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
13. Test instrumentation (TS9980 System) 
 
Equipment and Type 
Manufacturer 
Serial NO. 
  Signal Generator(SMG) 
  R & S 
835793/023 
  Signal Generator(SMG) 
  R & S 
835793/024 
  Signal Generator(SMX) 
  R & S 
837283/004 
  TV Patter Generator(SGPF) 
  R & S 
835773/001 
  Sound Tone(41.25MHz)(SBUF-E2) 
  R & S 
837859/001 
  TV Test Transmitter(SBUF) 
  R & S 
861456/025 
  RF Step attenuator(139dB)(DPSP) 
  R & S 
836731/003 
  Millivolt Meter(URV5) 
  R & S 
837256/001 
  Harmonic filter(ATS-OW) 
  R & S 
316977/003 
  Bandpass filter(0.5-3kHz)(BP) 
  Erika Fiedler 
6229 
  Isolation Transformer(TS-TT.3) 
  Volrio Star 
94/109738 
  Millivolt Meter(URV-3) 
  R & S 
836364/007 
  AC Millivolt meter(LMV-189AR) 
  Leader Electronicx 
1427669 
  'RF Power AMP(1347F/325LA) 
  ENI 
 
  Audio Analyzer(UPA) 
  R & S 
836798/010 
  RC Net Work(8,300ohm/RCo) 
  Erika Fiedler 
 
  Mains Filter(MSF) 
  Erika Fiedler 
 
  Coupling Unit(A,M,L,SR) 
  Erika Fiedler 
 
  Matching Net Work(MN) 
  Erika Fiedler 
 
  Mains Filter(M) 
  Erika Fiedler 
 
  Loudspeaker Filter(BS) 
  Erika Fiedler 
 
  RC Net Work(RCi,RCo) 
  Erika Fiedler 
 
  Signal Generator(MG3632A) 
  Anritsu Corp. 
MT39628 
 
 
 
WOORI Technology Inc.                        Page 18 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
14.  Figure 1 -  Test setup 
 
Figure 1-1 : 
S1
 Test Set-up 
 
 
 
 
 
 
 
 
 
 
 
 