WOORI Technology Inc.                        Page 12 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
10. Electrostatic Discharges (EN 61000-4-2) 
 
10.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
20  ℃ 
 
Relative Humidity: 
40 % 
 
 
A ground reference plane was located on the floor, and connected to earth via a low impedance connection 
The return cable of the ESD generator was connected to the reference plane. In case of a floor standing 
equipment, EUT was placed on the reference plane on 10cm of insulating support 
In case of table-top equipment, EUT was placed on a wooden table 0.8m above the reference planed On the 
floor. A horizontal coupling plane(HCP) of 1.6*0.8m was placed on the table, and connected to the reference 
plane via a cable with a 470 ㏀  resistor located in each end(0.5mm insulating support between EUT and HCP). 
In both cases a vertical coupling plane (VCP) of 0.5*0.5m was located 10cm from the EUT’s sides. 
The VCP was connected to the reference plane in the same matter as the HCP. 
The test was done by applying contact and air discharges to the EUT itself, and contact discharges to the 
HCP and VCP. When applying the discharges to the HCP, the tip of the generator was located at each side of the 
EUT, at 10cm distance. When applying the discharges to the VCP the tip of the generator was located at the 
middle edge of the VCP. The VCP was located 10cm from each side of the EUT. 
Contact discharges of  ±4kV were applied to various points of the EUT at conductive surfaces, and to the 
HCP/VCP. Air discharges of  ±8kV were applied to various points of the EUT at non-conductive surfaces. 
 
Instrumentation used during this session: 
 
Instruments 
Manufacturer 
Model 
Serial Number 
Due to Calibration
ESD Simulator 
Noiseken 
ESS-2000 
0199C02406 
2005. 02 
Discharge Gun 
Noiseken 
TCP-815P 
1199C02485 
2005. 02 
 
10.2 Test Parameters 
 Port: 
Enclosure 
 
Test Engineer: 
J. Y. Yu 
 Basic Standard:  EN 61000-4-2:1995 
 
Performance Criteria:  B 
 Test Level: 
Air Discharge: 
±8kV 
 
 
 
Contact Discharge: 
±4kV 
 
 
 
WOORI Technology Inc.                        Page 13 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
10.3  Test Log 
 
Point Voltage 
Coupling 
Result 
(Pass/Fail)
 HCP 
±4kV Contact 
Discharge 
Pass 
 VCP 
±4kV Contact 
Discharge 
Pass 
 Screws 
±4kV Contact 
Discharge 
Pass 
  Top, Rear, Sides 
±4kV Contact 
Discharge 
Pass 
 RCA Jack 
±4kV Contact 
Discharge 
Pass 
 RS-232 
±4kV Contact 
Discharge 
Pass 
 Front, Knobs 
±8kV Air 
Discharge 
Pass 
 Power Cord Bushing 
±8kV Air 
Discharge 
Pass 
 Headphone, A-BUS 
±8kV Air 
Discharge 
Pass 
 Remote 
±8kV Air 
Discharge 
Pass 
 
 
Comment/Performance 
No operation errors were detected during or after the discharges 
 
Result 
Compliant 
 
WOORI Technology Inc.                        Page 14 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
11. Radio-frequency, Electromagnetic Field Keyed Carrier Immunity test (EN61000-4-3) 
 
11.1 Test criteria and test procedure 
 
      Operating environment; 
 Temperature: 
20  ℃ 
 
Relative Humidity: 
40 % 
 
The tests were performed at 3m distance in an anechoic chamber.   
        For floor-standing equipment, the EuT was mounted non-conducting support 0.1m above the 
        supporting plane. For tabletop equipment, the EuT was located on a wooden table 0.8m above the floor. 
        The EuT was exposed to the field from different angles, normally 0。, 90。,180。,270。, 
        and at both horizontal and vertical polarization(antenna height 1.75m) 
        A signal level of 3V/m, duty cycle 1/8 Pulse modulated with 217Hz sine wave was applied in the   
frequency range 900MHz.   
 
Instrumentation used during this session: 
 
Instruments 
Manufacturer
Model 
Serial Number 
Due to Calibration
Signal Generator
 
R & S
 
SMY01
 
1062.5502.11
 
2004. 12 
Power Amplifier
 
Noiseken
 
NA25MF1G2010C
 
A00518
 
2005. 02 
Power Sensor
 
HP
 
8482A
 
U537293322
 
2005. 04 
Power Sensor
 
HP
 
8482A
 
U537293323
 
2005. 04 
Power Meter
 
HP
 
E4419B
 
GB39511164
 
2005. 04 
Biconical log Antenna
 
ARA
 
LPB-2520/A
 
1180
 
2005. 02 
Selective Level Meter
 
Anritsu
 
ML422B
 
M18572
 
2005. 07 
 
11.2 Test Parameters 
 
 Port: 
Enclosure 
 
Test Engineer: 
J. Y. Yu 
 Basic Standard:  EN 61000-4-3:2002 
 
Performance Criteria: 
 Dwell Time : 
3 Sec 
 Test 
Level 
3 Vrms 
Modulation : 
50% Duty PM @ 200 Hz 
Frequency Range : 
895-905 MHz 
 
WOORI Technology Inc.                        Page 15 of 104 
                               DPR 1005 (Harman Kardon)
 
EMC Test Report 
Reference No.: NK2EE 320.EMS 
 
 
11.3  Test Log 
 
Frequency  
Range (MHz) 
Position 
(Angle) 
Polarity 
(H or V) 
Field 
Strength 
(Vrms) 
Modulation 
Result 
(Pass/Fail) 
900 Front 
H  3 
Duty 
Cycle1/8 
PM(217Hz) 
Pass 
900 Rear 
H  3 
Duty 
Cycle1/8 PM(217Hz) 
Pass 
900 Right 
H  3 
Duty 
Cycle1/8 
PM(217Hz) 
Pass 
900 Left 
H  3 
Duty 
Cycle1/8 
PM(217Hz) 
Pass 
900 Front 
V  3 
Duty 
Cycle1/8 
PM(217Hz) 
Pass 
900 Rear 
V  3 
Duty 
Cycle1/8 PM(217Hz) 
Pass 
900 Right 
V  3 
Duty 
Cycle1/8 
PM(217Hz) 
Pass 
900 Left 
V  3 
Duty 
Cycle1/8 
PM(217Hz) 
Pass 
 
 
Comment/Performance 
The criterion of compliance with the requirement is satisfied with a wanted to unwanted audio signal 
ratio of  ≥40dB at a wanted audio signal level of 500mV   
 
Result 
Compliant 