Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377 page 41 of 323
5.2. Block Diagram of Test Setup
5.2.1.In Anechoic Chamber Test Setup Diagram for 30-1000MHz (at 10m Chamber)
5.2.2.in Anechoic Chamber Test Setup Diagram for 30-1000MHz (at 3m Chamber)
ANTENNA ELEVATION VARIES FROM 1 OR TO 4 METERS
10m
TURN TABLE
(FIBRE GLASS)
1.5m(L)*1.0m(W)*0.8m(H)
Receiver
Semi-Anechoic 10m Chamber
EUT
Combining Network
AMP
Spectrum Analyzer
PC System
0.8m
Antenna Elevation Varies From 1 to 4 m(for Horizontal)
2 to 4 m (for Vertical)
3.0m
Turn Table
(Wood)
1.5m(L)*1.0m(W)*0.8m(H)
Receiver
Semi-Anechoic 3m Chamber
EUT
Combining Network
AMP
Spectrum Analyzer
PC System
(
Reference Point
)
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377 page 42 of 323
5.2.3. In Anechoic (3m) Chamber Test Setup Diagram for 1-6GHz
5.3. Test Standard
EN55022: 2010 (Class B) and EN 55013: 2001+A1: 2003+A2:2006
5.4. Radiated Emission Limit
All emanations from a devices or system, including any network of conductors and
apparatus connected thereto, shall not exceed the level of field strengths specified below:
Test Standard: EN55013: 2001+A1: 2003+A2:2006
Test Standard: EN55013: 2001+A1: 2003+A2:2006
DISTANCE
Source
(Meters)
FREQUENCY
(MHz)
Limits(dB
μV/m)
Quasi-Peak
3
≦
1000
Fundamental 60
3
30~300
Harmonics 52
Local Oscillator
3
300~1000
Harmonics 56
3 30~230
40
Other
3 230~1000
47
Note:
(1) Emission level = Antenna Factor + Cable Loss + Reading
(2) The lower limit shall apply at the transition frequencies.
(3) Distance refers to the distance in meters between the test instrument
antenna and the closed point of any part of the E.U.T.
0.8m
Antenna Elevation Varies From 1 to 4 m
3.0m
Turn Table
(Wood)
1.5m(L)*1.0m(W)*0.8m(H)
Receiver
Semi-Anechoic 3m Chamber
EUT
Combining Network
AMP
Spectrum Analyzer
PC System
(
Reference Point
)
ABSORBER
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377 page 43 of 323
Test Standard: EN55022: 2010
FREQUENCY
(MHz)
DISTANCE
(Meters)
FIELD STRENGTHS LIMITS
(dB
μV/m)
30 ~ 230
10
30
230 ~ 1000
10
37
1000~3000 3 70(Peak)
50(Average)
3000~6000 3 74(Peak)
54(Average)
Note:
(1) Emission level = Antenna Factor + Cable Loss + Reading
Emission level = Antenna Factor -Amp Factor +Cable Loss + Reading
(above 1000MHz)
(2) The lower limit shall apply at the transition frequencies.
(3) Distance refers to the distance in meters between the test instrument
antenna and the closed point of any part of the E.U.T.
5.5. EUT Configuration on Test
The configurations of EUT are listed in Section 3.5.
5.6. Operating Condition of EUT
Same as Conducted Emission test that is listed in Section 3.6. except the test set up replaced
by Section 5.2.
5.7. Test Procedure
The EUT was placed on a non-metallic table, 80 cm above the ground plane inside a
semi-anechoic chamber. An antenna was located 3 & 10 meters from the EUT on an
adjustable mast. A pre-scan was first performed in order to find prominent radiated
emissions. For final emissions measurements at each frequency of interest, the EUT were
rotated and the antenna height was varied between 1m and 4m in order to maximize the
emission for EN55022. 2m and 4m on vertical for EN55013. Measurements in both
horizontal and vertical polarities were made and the data was recorded. In order to find the
maximum emission, the relative positions of equipments and all of the interface cables
were changed according to EN55013 and EN 55022 Class B on Radiated Disturbance test.
adjustable mast. A pre-scan was first performed in order to find prominent radiated
emissions. For final emissions measurements at each frequency of interest, the EUT were
rotated and the antenna height was varied between 1m and 4m in order to maximize the
emission for EN55022. 2m and 4m on vertical for EN55013. Measurements in both
horizontal and vertical polarities were made and the data was recorded. In order to find the
maximum emission, the relative positions of equipments and all of the interface cables
were changed according to EN55013 and EN 55022 Class B on Radiated Disturbance test.
The bandwidth setting on the test receiver (R&S TEST RECEIVER ESVS10&ESCI) is
120 kHz.
The resolution bandwidth of the Agilent Spectrum Analyzer E7405A was set at 1MHz.
The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and
all final readings of measurement from Test Receiver are Quasi-Peak values.
The frequency range from 1GHz to 6GHz was checked and all final readings of
measurement were with Peak and Average detector, measurement distance was 3m at
semi-anechoic chamber. The portion of the test volume that was obstructed by absorber
placed on the floor (30cm maximum).
Finally, selected operating situations at Anechoic Chamber measurement, all the test
results are listed in section 5.8.
120 kHz.
The resolution bandwidth of the Agilent Spectrum Analyzer E7405A was set at 1MHz.
The frequency range from 30MHz to 1000MHz was pre-scanned with a peak detector and
all final readings of measurement from Test Receiver are Quasi-Peak values.
The frequency range from 1GHz to 6GHz was checked and all final readings of
measurement were with Peak and Average detector, measurement distance was 3m at
semi-anechoic chamber. The portion of the test volume that was obstructed by absorber
placed on the floor (30cm maximum).
Finally, selected operating situations at Anechoic Chamber measurement, all the test
results are listed in section 5.8.
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E12377 page 44 of 323
5.8. Radiated Emission Test Results
PASS. (All emissions not reported below are too low against the prescribed limits.)
For frequency range 30MHz~1000MHz
The EUT with the following test modes were tested and selected (mode 1~4) to read Q.P
values, all the test results are listed in next pages.
The EUT with the following test modes were tested and selected (mode 1~4) to read Q.P
values, all the test results are listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model No. : BDS575
Test Date: Jun.30, 2012 Temperature: 24℃ Humidity: 56%
The details of test modes are as follows:
Reference Test Data No.
No. Test
Mode
Horizontal
Vertical
1. ※
BD Live
#2
#1
2.
FM 88MHz
#41
#42
3. FM
98MHz
#44
#43
4. FM
108MHz
#45
#46
( Worst test mode)
※
For above 1GHz frequency
The EUT with below test mode 1 was measured within 3m Anechoic Chamber and the test
results listed in next pages.
All the emissions form 1GHz to 6GHz were PK measured and comply with Average limit,
so the average levels were deemed to comply with average limit.
Test Date: Jun.30, 2012 Temperature: 24℃ Humidity: 56%
The EUT with below test mode 1 was measured within 3m Anechoic Chamber and the test
results listed in next pages.
All the emissions form 1GHz to 6GHz were PK measured and comply with Average limit,
so the average levels were deemed to comply with average limit.
Test Date: Jun.30, 2012 Temperature: 24℃ Humidity: 56%
Reference Test Data No.
No. Test
Mode
Horizontal
Vertical
1.
BD Play
#40
#39