DOWNLOAD Harman Kardon BDS 270 (serv.man4) Service Manual ↓ Size: 15.07 MB | Pages: 127 in PDF or view online for FREE

Model
BDS 270 (serv.man4)
Pages
127
Size
15.07 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
bds-270-sm4.pdf
Date

Harman Kardon BDS 270 (serv.man4) EMC - CB Certificate ▷ View online

R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588      page 33 of 336 
 
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588      page 34 of 336 
 
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588      page 35 of 336 
 
 
R
 
AUDIX Technology (Shenzhen) Co., Ltd.
 
 
                                    Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588      page 36 of 336 
 
4.  CONDUCTED DISTURBANCE AT TELECOMMUNICATION 
PORTS TEST 
4.1.  Test Equipments 
Item 
Equipment 
Manufacturer 
Model No.
Serial No. 
Last Cal.  Cal. Interval
1.   
Test Receiver 
Rohde & Schwarz
ESHS10 
838693/001  Nov. 05, 10 
1 Year 
2.   
L.I.S.N.#1 
Rohde & Schwarz ESH2-Z5 
834066/011  Nov. 05, 10 
1 Year 
3.   
L.I.S.N.#3 
Kyoritsu 
KNW-242C
8-1920-1 
May 08, 11 
1 Year 
4.   
Terminator EMCO 50
Ω 
No. 1 
May 08, 11 
1 Year 
5.   
Terminator EMCO 50
Ω 
No. 2 
May 08, 11 
1 Year 
6.   
RF Cable 
Fujikura 
3D-2W 
LISN Cable 1#  May 08, 11 
1Year 
7.   
Current Probe 
Rohde & Schwarz
EZ-17 
833335/009  Nov. 05, 10 
1 Year 
8.   Four 
Balanced 
Telecom Pairs ISN 
FCC FCC-TLISN
-T8-02 
20412 
May 08, 11 
1Year 
9.    Coaxial Switch 
Anritsu 
MP59B 
M55367 
May 08, 11 
1Year 
10.   
Pulse Limiter 
Rohde & Schwarz ESH3-Z2 
100341 
May 08, 11 
1 Year 
 
4.2.  Block Diagram of Test Setup 
 
4.3.  Test Standard 
EN 55022: 2006+A1: 2007 
4.4.  Conducted Disturbance at Telecommunication Ports Limit 
Maximum RF Line Voltage 
Frequency 
Quasi-Peak Level 
dB(
μV) 
Average Level 
dB(
μV) 
150kHz ~ 500kHz 
84~74 
74~64 
500kHz ~ 30MHz 
74 
64 
Notes: 1. * Decreasing linearly with logarithm of frequency. 
2. The lower limit shall apply at the transition frequencies. 
EUT
LISN #1
PC System
LISN #3
0.8m
80cm
Receiver
ISN 
AE 
:50
Ω Terminator;    a: Lan Line 
a
a
Page of 127