Harman Kardon BDS 270 (serv.man4) EMC - CB Certificate ▷ View online
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588 page 37 of 336
4.5. EUT Configuration on Test
The configurations of EUT are listed in Section 3.5
4.6. Operating Condition of EUT
4.6.1. Setup the EUT and simulators as shown in Section 4.2.
4.6.2. Turn on the power of all equipments.
4.6.3. The EUT link to PC and which transmitted data via running “TFGEN.exe”
4.6.2. Turn on the power of all equipments.
4.6.3. The EUT link to PC and which transmitted data via running “TFGEN.exe”
software., In order to make reliable emission measurement representative of high
LAN utilization it is only necessary to create a condition of LAN utilization in excess
of 10% and sustain that level for a minimum of 250ms.
LAN utilization it is only necessary to create a condition of LAN utilization in excess
of 10% and sustain that level for a minimum of 250ms.
4.6.4. The other peripheral devices were driven and operated in turn during all testing.
4.7. Test Procedure
The EUT was placed on a non-metallic table, 80cm above the ground plane. The EUT
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1). This provided a 50-ohm coupling impedance for the EUT (Please refer to
the block diagram of the test setup and photographs). The other peripheral devices power
cord connected to the power mains through a line impedance stabilization network
(L.I.S.N.#3). Both sides of power line were checked for maximum conducted interference.
In order to find the maximum emission, the relative positions of equipments and all of the
interface cables were changed according to EN 55022: 2006+A1:2007 on Conducted
Disturbance test.
And connected to the telecommunication ports through ISN. Both sides of
telecommunication line are investigated to find out the maximum conducted emission
according to EN 55022: 2006+A1:2007 regulations during conducted disturbance test.
The bandwidth of the test receiver (R&S Test Receiver ESHS 10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 4.8.
Power connected to the power mains through a line impedance stabilization network
(L.I.S.N. #1). This provided a 50-ohm coupling impedance for the EUT (Please refer to
the block diagram of the test setup and photographs). The other peripheral devices power
cord connected to the power mains through a line impedance stabilization network
(L.I.S.N.#3). Both sides of power line were checked for maximum conducted interference.
In order to find the maximum emission, the relative positions of equipments and all of the
interface cables were changed according to EN 55022: 2006+A1:2007 on Conducted
Disturbance test.
And connected to the telecommunication ports through ISN. Both sides of
telecommunication line are investigated to find out the maximum conducted emission
according to EN 55022: 2006+A1:2007 regulations during conducted disturbance test.
The bandwidth of the test receiver (R&S Test Receiver ESHS 10) is set at 10kHz.
The frequency range from 150kHz to 30MHz is checked. The test result are reported on
Section 4.8.
4.8. Conducted Disturbance at Telecommunication Ports Test Results
PASS.
The EUT with the following test modes were tested to read Q.P values and average values,
all the test results are listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model Number: BDS570
Test Date: Jun.28, 2011 Temperature: 29.5℃ Humidity: 55%
The details of test mode as follows:
all the test results are listed in next pages.
EUT: BLU-RAY DISC SYSTEM Model Number: BDS570
Test Date: Jun.28, 2011 Temperature: 29.5℃ Humidity: 55%
The details of test mode as follows:
No.
Test Port
Test Mode
Reference Test Data No.
1. LAN
100Mbps
#19
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588 page 38 of 336
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588 page 39 of 336
5. RADIATED EMISSION TEST
5.1. Test Equipments
The following test equipments are used during the radiated emission measurement:
5.1.1. For frequency range 30MHz~1000MHz
Item
Equipment
Manufacturer
Model No.
Serial No.
Last Cal. Cal. Interval
1 3#Chamber
AUDIX
N/A
N/A Dec.06,10 1
Year
2 EMI Spectrum
Agilent
E4407B
MY41440292 May 08, 11
1 Year
3
Test Receiver Rohde & Schwarz
ESVS10
834468/011 May 08, 11
1 Year
4
Amplifier
HP
8447D
2648A04738 May 08, 11
1
Year
5 Bilog Antenna
Schaffner
CBL6111C
2598
Oct. 26, 10
1 Year
6 RF
Cable MIYAZAKI 8D-FB
3# Chamber No.1
May 08, 11
1 Year
7 Coaxial
Switch
Anritsu
MP59B
M73989
May 08, 11
1 Year
5.1.2. For frequency range
1GHz~6GHz (At Anechoic Chamber)
Ite
m
Equipment
Manufacturer
Model No.
Serial No.
Last Cal. Cal. Interval
1 Spectrum Analyzer
Agilent
E4407B
MY41440292 May.08, 11
1 Year
2
Horn Antenna
EMCO
3115
9607-4877 July.01, 11
1 Year
3
Amplifier
Agilent
8449B
3008A00863 May.08, 11
1 Year
4
RF Cable
Hubersuhner SUCOFLEX102
28622/2
May.08, 11
1 Year
5
RF Cable
Hubersuhner SUCOFLEX102
29091/2
May.08, 11
1 Year
R
AUDIX Technology (Shenzhen) Co., Ltd.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E11588 page 40 of 336
5.2. Block Diagram of Test Setup
5.2.1. In Anechoic Chamber Test Setup Diagram for 30-1000MHz
5.2.2. Anechoic Chamber Test Setup Diagram for 1-6GHz
0.8m
Antenna Elevation Varies From 1 to 4 m
3.0m
Turn Table
(Wood)
1.5m(L)*1.0m(W)*0.8m(H)
Receiver
Semi-Anechoic 3m Chamber
EUT
Combining Network
AMP
Spectrum Analyzer
PC System
(
Reference Point
)
0.8m
Antenna Elevation Varies From 1 to 4 m
3.0m
Turn Table
(Wood)
1.5m(L)*1.0m(W)*0.8m(H)
Receiver
Semi-Anechoic 3m Chamber
EUT
Combining Network
AMP
Spectrum Analyzer
PC System
(
Reference Point
)
Click on the first or last page to see other BDS 270 (serv.man4) service manuals if exist.