DOWNLOAD Harman Kardon AVR 70 2012 Service Manual ↓ Size: 2.22 MB | Pages: 56 in PDF or view online for FREE

Model
AVR 70 2012
Pages
56
Size
2.22 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-70-2012.pdf
Date

Harman Kardon AVR 70 2012 EMC - CB Certificate ▷ View online

Page 27 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
supply 
voltage(
V) 
dT (K) / Component 
Other results 
(include description and test duration) 
duration of  
the test 
Input  
current(A) 
result, state effect of fault condition 
14. D131 
S/C 
242 V 
32 min 
0.21 
Immediately R198 opened. NB. No 
hazard. 
15. D134 
S/C 
242 V 
34 min 
0.21 
Immediately R208 opened. NB. No 
hazard. 
16. IC111(In 
– Out)  S/C 
242 V 
1 h, 12 
min 
1.03 
IC111 heated up to 56 K and stabilized. 
NCD. No hazard. 
17. C222 
S/C 
242 V 
1 h, 05 
min 
1.04 
IC111 heated up to 66 K and stabilized. 
NCD. No hazard. 
18. IC112(In 
– Out)  S/C 
242 V 
35 min 
1.03 
Normal operation. NCD. No hazard. 
19. C219 
S/C 
242 V 
1 h, 18 
min 
1.04 
IC112 heated up to 69 K and stabilized. 
NCD. No hazard. 
20. IC108(In 
– Out)  S/C 
242 V 
31 min 
1.03 
Normal operation. NCD. No hazard. 
21. C223 
S/C 
242 V 
1 h, 09 
min 
1.04 
NCD. No hazard. 
22. C198 
S/C 
242 V 
35 min 
0.21 
Immediately R198, R208 opened. NB. No 
hazard. 
23. C206 
S/C 
242 V 
30 min 
0.21 
Immediately R198, R208 opened. NB. No 
hazard. 
24. IC103 (In 
– 
Out) 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
25. IC104 (In 
– Out) 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
26. C205 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
27. C204 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
28. D117 
S/C 
242 V 
33 min 
1.03 
NCD. No hazard. 
29. C176 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
30. C260 
S/C 
242 V 
45 min 
1.03 
Immediately R263 damaged. NB. No 
hazard. 
31. ZD102 
S/C 
242 V 
48 min 
1.04 
R143 heated up to 81.5 K and stabilized. 
NCD. No hazard. 
32. IC105(4 
– 8) 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
33. IC105(4 
– 5) 
S/C 
242 V 
28 min 
1.03 
Normal operation. NCD. No hazard. 
34. IC105(4 
– 6) 
S/C 
242 V 
30 min 
1.03 
Normal operation. NCD. No hazard. 
35. IC105(4 
– 7) 
S/C 
242 V 
26 min 
1.03 
Normal operation. NCD. No hazard. 
Page 28 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
supply 
voltage(
V) 
dT (K) / Component 
Other results 
(include description and test duration) 
duration of  
the test 
Input  
current(A) 
result, state effect of fault condition 
36. IC114(In 
– Out)  S/C 
242 V 
26 min 
1.03 
Normal operation. NCD. No hazard. 
37. C172 
S/C 
242 V 
48 min 
1.04 
IC114 heated up to 54.5 K and stabilized. 
NCD. No hazard. 
38. IC110(In 
– Out)  S/C 
242 V 
33 min 
1.03 
NCD. No hazard. 
39. C170 
S/C 
242 V 
45 min 
1.04 
IC110 heated up to 54.8 K and stabilized. 
NCD. No hazard. 
40. D303 
S/C 
242 V 
2 h, 10 
min 
0.05 
Immediately protection circuit(RLY301) 
operated. Priwinding of standby 
transformer heated up to 42.3 K and 
stabilized. NCD. No hazard. 
41. D306 
S/C 
242 V 
1 h, 54 
min 
0.06 
Immediately protection circuit(RLY301) 
operated. Primary winding of standby 
transformer heated up to 47,5 K and 
stabilized. NCD. No hazard. 
42. C302 
S/C 
242 V 
1 h, 55 
min 
0.06 
Immediately protection circuit(RLY301) 
operated. Primary winding of standby 
transformer heated up to 47,0 K and 
stabilized. NCD. No hazard. 
44. C301 
S/C 
242 V 
2 h, 21 
min 
0.06 
Immediately protection circuit(RLY301) 
operated. Primary winding of standby 
transformer heated up to 47,4 K and 
stabilized. NCD. No hazard. 
45. IC300(In 
– Out)  S/C 
242 V 
3 s 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
46. C300 
S/C 
242 V 
49 min 
0.04 
Immediately protection circuit(RLY301) 
operated. IC300 heated up to 17.8 K. 
NCD. No hazard. 
47. C709 
S/C 
242 V 
33 min 
1.05 
Immediately front display disappeared. 
No hazard. NCD. No hazard. 
48. C708 
S/C 
242 V 
33 min 
1.05 
Immediately front display disappeared. 
No hazard. NCD. No hazard. 
49. Q205FR (B 
– 
C) 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
50. Q205FR (C 
– 
E) 
S/C 
242 V 
1 min 
0.04 
Immediately R220FR, R221FR, R222FR, 
R223FR opened. R219FR damaged. 
Q206FR shorted. Protection 
circuit(RLY301) operated. NB. No hazard. 
51. Q205FR (B 
– E)  S/C 
242 V 
33 min 
1.03 
Normal operation. NCD. No hazard. 
52. Q206FR (B 
– C)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
Page 29 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
supply 
voltage(
V) 
dT (K) / Component 
Other results 
(include description and test duration) 
duration of  
the test 
Input  
current(A) 
result, state effect of fault condition 
53. Q206FR (C 
– E)  S/C 
242 V 
1 min 
0.04 
Immediately R220FR, R221FR, R222FR, 
R223FR opened.  R218FR damaged. 
Q205FR shorted. Protection 
circuit(RLY301) operated. NB. No hazard. 
54. Q206FR (B 
– E)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
55. Q203FR (B 
– E)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
56. Q203FR (B 
– C)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
57. Q203FR (C 
– E)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
58. Q202FR (B 
– C)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
59. Q202FR (B 
– E)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
60. Q202FR (C 
– E)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
61. Q201FR (B 
– E)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
62. Q201FR (B 
– C)  S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
63. Q201FR (C
– E) 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit(RLY301) 
operated. NCD. No hazard. 
64. C212 
S/C 
242 V 
1 min 
0.04 
Immediately R229 opened. Potection 
circuit(RLY301) operated. NB. No hazard 
65. IC106(In 
– Out) 
S/C 
242 V 
43 min 
1.03 
NCD. No hazard. 
66. C162 
S/C 
242 V 
35 min 
1.03 
NCD. No hazard. 
67. IC110(In 
– Out) 
S/C 
242 V 
32 min 
1.03 
NCD. No hazard. 
68. C219 
S/C 
242 V 
36 min 
1.03 
NCD. No hazard. 
69. IC111(In 
– Out) 
S/C 
242 V 
29 min 
1.03 
NCD. No hazard. 
70. C230 
S/C 
242 V 
33 min 
1.03 
NCD. No hazard. 
71. IC114(In 
– Out) 
S/C 
242 V 
37 min 
1.03 
NCD. No hazard. 
72. IC114(Out 
– G) 
S/C 
242 V 
41min 
1.03 
NCD. No hazard. 
73. IC121(In 
– Out) 
S/C 
242 V 
30min 
1.03 
NCD. No hazard. 
74. C358 
S/C 
242 V 
37 min 
1.03 
NCD. No hazard. 
Page 30 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
supply 
voltage(
V) 
dT (K) / Component 
Other results 
(include description and test duration) 
duration of  
the test 
Input  
current(A) 
result, state effect of fault condition 
75. USB 
SC 
242 
1 min 
0** 
Immediately IC2024 shut down. NCD. 
No hazard. 
76. USB 
OL 
242 
4 h, 23 
min 
0.54** 
IC108 heated up to 78.9 K and 
stabilized. NCD. No hazard. 
77.  Right  speaker 
terminal (1/8 Pmax) 
S/C 
242 V 
1 min 
0.04 
Immediately protection circuit (RLY301)       
operated. NCD. No hazard. 
78. closed 
ventilation (1/8 
Pmax) 
 
242 V 
4 h, 13 
min 
1.03 
Primary  winding of main transformer 
heated up to 95.0 K and stabilized. NCD. 
No hazard. 
79. Pmax (5 
channels)* 
 
242 V 
27 min 
0.04 
Primary winding of main transformer 
heated up to 132.1 K and thermal fuse 
opened. NB. No hazard. 
80. 2 Ohm load test 
(5 channels) 
 
242 V 
4 h, 06 
min 
1.84 
Primary  winding of main transformer 
heated up to 119.4 K and stabilized. 
NCD. No hazard. 
s/c: short circuit, NCD: No component damaged, NB: No Breakdown 
*: means, the tests were repeated all three times and same results were obtained. 
**:means, the value of this column is final fault current through related component. 
  
 
Page of 56
Display