Harman Kardon AVR 70 2012 EMC - CB Certificate ▷ View online

Page 15 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
Between conductors of fuse    
holders: F301: min. 3.5 mm  
14.5.1.1 
a) Thermal cut-outs separately approved  
No thermal cut-outs 
N/A 
 
b) Thermal cut-outs tested as part of the submission   
N/A 
14.5.1.2 
a) Thermal links separately approved  
Certified thermal fuse provided 
in the main transformer 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
(see appended table) 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : 
F301:T 4 AL 250 V 
14.5.2.3 
Not possible to connect fuses in parallel  ................ : 
 
N/A 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
Fuse-link were located in the 
apparatus 
N/A 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
No PTC 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked  
Such protective devices are 
not provided 
N/A 
14.6 
Switches  
(See appended table) 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
1.07 A, Cl.7.1 at 242 V~;  
Mains switch and relay were 
approved  by TUV or SEMKO. 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage  
< 35 V (peak)/24 V dc complying with 14.3.15 And 
V-0 in annex G, G.1.1  
 
N/A 
 
Switch controlling < 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 
N/A 
Page 16 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
 
N/A 
 
Socket outlet current marking correct  
 
N/A 
14.7 
Safety interlocks  
No safety interlocks 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
No voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 
N/A 
14.9 
Motors 
No motors 
N/A 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 
N/A 
14.10 
Batteries 
No batteries 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 
Optocouplers  
No optocouplers 
N/A 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
 
b) Comply with IEC 60747-5-5:2007 
 
N/A 
 
Alternative to a) and b) optocoupler comply with 13.8   
N/A 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
14.12 
Surge suppression varistors  
No varistors 
N/A 
 
Comply with IEC 61051-2  
 
N/A 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
Yes 
N/A 
Page 17 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 
N/A 
 
15 
Terminals 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
(see appended table 14) 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
 
N/A 
 
No risk of insertion in mains socket-outlets  
 
N/A 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
No terminals like 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets  
No terminals like 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II equipment 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A  ................... : 
 
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
No permanently connected 
apparatus 
N/A 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
 
N/A 
 
Not soldered to conductors of a printed circuit board   Crimped contacts within plug 
connector 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
Wires are crimped two times to 
the contact and provided with a 
two pole-connector 
 
Wire secured by additional means to the  
conductor   
Wires insulators are crimped 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
None 
N/A 
Page 18 of 33 
Report No.: 077-207362-000 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
None 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
Crimped the insulators and 
conductors 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16   No terminals like 
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
No terminals like 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 
N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
No terminals like 
N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
Crimped contacts within plug 
connector 
15.4 
Devices forming a part of the mains plug  
 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
No devices like 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ : 
PVC sheathed (refer to 
appended table 14) 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
Class II 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
1.07 A, Cl.7.1 at 242 V ~: 2 
 
min. 0.75 mm
2
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
No interconnection cord 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)  
 
N/A 