DOWNLOAD Harman Kardon AVR 630 (serv.man4) Service Manual ↓ Size: 1.57 MB | Pages: 48 in PDF or view online for FREE

Model
AVR 630 (serv.man4)
Pages
48
Size
1.57 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-630-sm4.pdf
Date

Harman Kardon AVR 630 (serv.man4) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 7 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
7.1  
 
Standby mode: 
 U 
= 
207,0
 V, I 
= 
0,038
 A, P 
= 
7,3 
W, 
Pout = 
 
W 
 U 
= 
230,0
 V, I 
= 
0,039
 A, P 
= 
8,5 
W, 
Pout = 
 
W 
U = 
254,4
 V, I 
= 
0,042
 A, P 
= 
9,8 
W, 
Pout = 
 
W 
 
 
Measured at maximum non-clipped output:   
 U 
= 
207,0
 V, I 
= 
 
5,35
 A, P 
= 
926 
W, 
Pout = 
2 x 79,7 
(F)
 
   
 
 
 
 
 
 
1 x 81,9
 W 
(C)
 
   
 
 
 
 
 
 
2 x 77,2
 W 
(S) 
 
 
  
  
  
81,8
 W 
(S/B)
 
 U 
= 
230,0
 V, I 
= 
 
5,64
 A, P 
= 
1070
 
W, 
Pout = 
2 x 79,7 
(F)
 
   
 
 
 
 
 
 
1 x 81,9
 W 
(C)
 
   
 
 
 
 
 
 
2 x 77,2
 W 
(S) 
 
 
  
  
  
81,8
 W 
(S/B)
 
U = 
254,4
 V, I 
= 
 
5,68
 A, P 
= 
1193 
W, 
Pout = 
2 x 79,7 
(F)
 
   
 
 
 
 
 
 
1 x 81,9
 W 
(C)
 
   
 
 
 
 
 
 
2 x 77,2
 W 
(S) 
 
 
  
  
  
81,8
 W 
(S/B)
 
 
 
 
LSL =
  7 channels x 8
 
 
 
 
Measured at 1/8 of maximum non-clipped output:   
 U 
= 
207,0
 V, I 
= 
 
2,52
 A, P 
= 
402 
W, 
Pout = 
2 x 10,0 
(F)
 
   
 
 
 
 
 
 
1 x 10,2
 W 
(C)
 
   
 
 
 
 
 
 
2 x 9,7
 W 
(S) 
 
 
  
  
  
10,2
 W 
(S/B)
 
 U 
= 
230,0
 V, I 
= 
 
2,58
 A, P 
= 
452
 
W, 
Pout = 
2 x 10,0 
(F)
 
   
 
 
 
 
 
 
1 x 10,2
 W 
(C)
 
   
 
 
 
 
 
 
2 x 9,7
 W 
(S) 
 
 
  
  
  
10,2
 W 
(S/B)
 
U = 
254,4
 V, I 
= 
 
2,61
 A, P 
= 
503 
W, 
Pout = 
2 x 10,0 
(F)
 
   
 
 
 
 
 
 
1 x 10,2
 W 
(C)
 
   
 
 
 
 
 
 
2 x 9,7
 W 
(S) 
 
 
  
  
  
10,2
 W 
(S/B)
 
 
 
 
LSL =
  7 channels x 8
 
 
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 8 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
7.1  
 
 
Operating conditions (power audio amplifier, 1/8 of maximum non clipped output): 
U = 
254,4
 V, I 
= 
 
2,61
 A, P 
= 
503 
W, 
Pout = 
2 x 10,0 
(F)
 
   
 
 
 
 
 
 
1 x 10,2
 W 
(C)
 
   
 
 
 
 
 
 
2 x 9,7
 W 
(S) 
 
 
  
  
  
10,2
 W 
(S/B)
 
 
 
 
LSL =
  7 channels x 8
 
 
 
 Loudspeaker 
system(s) 
 
Only one for Center, 
 
 
 
 
Right and Left for Surround,
 
 
 
 
 
Right and Left for Front,  
                                                    
Right and Left for for Surround Back channels.
 
 
Marking of loudspeaker terminals   
SPEAKERS ( 8 
 ) : 
 
 
 
FR, FL, SR, SL, CTR,   
 
 
 
SBR/MULTI R, SBL/MULTI L
. 
 
U =
 254,4 
V 
6 Ohm 
8 Ohm 
16 Ohm 
 
 
 
 
left left right 
right 
left 
right 
left 
right
Measured max. output voltage    in Vp 
  F) 
35,7 
 
C) 36,2 
S) 35,1 
S/B) 36,2 
F) 35,7   
C) - 
S) 35,1 
S/B) 36,2 
 
 
 
 
Measured max. output power    in W
 
 
  F) 
79,7 
C) 81,9 
S) 77,2 
S/B) 81,8 
F) 79,7 
C) - 
S) 77,2 
S/B) 81,8 
 
 
 
 
Measured max. mains power in W 
1193 
 
 
 
 
Operation of protective devices     
No fuse links operate during normal operating condition 
7.1.1 
Temperature rise of accessible parts 
(see table next page) 
7.1.2 
Temperature rise of parts providing 
electrical insulation   
(see table next page) 
7.1.3 
Temperature rise of parts acting as a 
support or as a mechanical barrier   
(see table next page) 
7.1.4 
Temperature rise of windings   
(see table next page) 
7.1.5 
Parts not subject to a limit under 
7.1.1 to 7.1.4   
(see table next page) 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 9 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
HEATING  
 
t =    ( R2 - R1)        x (234,5 + t1) - (t2 - t1) 
                              R1 
t1 =   
24,2 °C 
24,2 °C
 
 
t2 =   
24,7 °C 
20,3 °C
 
 
Test voltage   
207 V 
254,4 V
 
 
Winding 
R1/
 R2/
 
t measured 
t allowed *) 
Insulation 
class 
  Main transf. pr. winding (207V) 
1,583 
1,967 
62,3 
85 
Class E 
  Sub transf. pr. winding (207V) 
690 
830 
52,0 
85 
Class E 
 
 
 
 
 
 
  Main transf. pr. winding (254,4V) 
1,583 
2,000 
72,0 
85 
Class E 
  Sub transf. pr. winding (254,4V) 
690 
846 
62,4 
85 
Class E 
 
 
 
 
 
 
Other measured parts 
t measured 
at 207V 
t measured 
at 254,4V 
t allowed *) 
Main transformer core 
46,7 
53,8 
85 
Sub transformer core 
37,6 
45,6 
85 
Diode, D201 body 
48,7 
49,8 
PWB near D201 
34,5 
37,9 
85 
PWB near D501 
44,1 
47,7 
85 
D501 
heat-sink 
47,8 49,5 - 
Diode, D502 body 
27,8 
32,7 
Diode, D503 body 
25,8 
31,1 
TR, Q318 body 
44,1 
57,5 
PWB near Q318 
33,0 
38,8 
85 
TR, Q438 body 
52,4 
68,0 
PWB near Q438 
46,9 
60,2 
85 
E. Capacitor, C201 body 
21,2 
23,0 
E. Capacitor, C514 body 
21,8 
26,5 
E. Capacitor, C517 body 
20,6 
23,2 
E. Capacitor, C571 body 
27,3 
30,1 
IC11 
heat-sink 
32,6 40,4 - 
IC, IC55 body 
41,8 
53,9 
IC55 
heat-sink 
40,8 55,2 - 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 10 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
Other measured parts 
t measured 
at 207V 
t measured 
at 254,4V 
t allowed *) 
Fan 
guard 
19,9 24,8 60 
Main 
heat-sink 
35,8 45,9 - 
Appliance inlet body 
15,0 
15,8 
60 
Top enclosure above main heat-sink 
6,5 
13,6 
40 
Switch 
button 
0,6 1,8 50 
Comments  
 
 
No other parts were observed to create any hazard due to temperature rise.   
 
Test wall condition: 50 cm at top, 10 cm at other side 
 
 
*) Temperature rise limits for Singapore is 10K less. 
 
 
 
 
 
7.2 
Softening temperature of insulating 
material supporting parts 
conductively connected to the mains 
carrying a current > 0,2 A at least 
150 
°
C  
No temperature measured during heating test and fault 
cond. tests requires this test (7.2) to be performed. 
Tested parts 
Temperature   
under normal 
operating con- 
ditions (°C) 
Temperature  
under fault 
conditions  
            (°C) 
Softening 
temperature 
            (°C) 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 48
Display