FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Q334 
S-c 
254,4 
B - C 
10 min 
F101 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
Q334, Q336 damaged. 
No hazard. 
Q330 
S-c 
254,4 
B - E 
30 min 
F101 
2,61 A 
Normal operating. 
Input current stabilised at 2,61A. 
No component damaged. 
No hazard. 
Q336 
S-c 
254,4 
C - E 
10 min 
F101 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
Q330, Q334, R374 damaged. 
No hazard. 
Q336 
S-c 
254,4 
B - C 
10 min 
F101 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
Q334, Q336 damaged. 
No hazard. 
Q332 
S-c 
254,4 
B - E 
30 min 
F101 
2,61 A 
Normal operating. 
Input current stabilised at 2,61A. 
No component damaged. 
No hazard. 
D502 
S-c 
254,4 
AC - + 
10 min 
F101 
F501 
F502 
2,61 A 
Normal operating. 
Input current stabilised at 2,58A. 
F501 opened. 
No hazard. 
C509 S-c 
207  - 
10 
min 
F101 
F501 
F502 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
F501, F502 opened. 
No hazard. 
C509 S-c 
254,4 - 
10 
min 
F101 
F501 
F502 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
F501, F502 opened. 
No hazard. 
IC51 
S-c 
254,4 
In - G 
10 min 
F101 
F501 
F502 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard. 
C518 S-c 
254,4 - 
30 
min 
F101 
F501 
F502 
1,00 A 
Output signal off immediately. 
Input current stabilised at 0,82A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D503 
S-c 
254,4 
AC - + 
10 min 
F101 
F503 
F504 
2,59 A 
Normal operating. 
Input current stabilised at 2,56A. 
F503 opened. 
No hazard. 
C514 S-c 
207  - 
10 
min 
F101 
F503 
F504 
2,80 A 
Normal operating. 
Input current stabilised at 2,48A. 
F503, F504 opened. 
No hazard. 
C514 S-c 
254,4 - 
10 
min 
F101 
F503 
F504 
2,81 A 
Normal operating. 
Input current stabilised at 2,54A. 
F503, F504 opened. 
No hazard. 
IC53 
S-c 
254,4 
In - G 
30 min 
F101 
F503 
F504 
2,69 A 
Normal operating. 
Input current stabilised at 2,56A. 
R506 damaged. 
No hazard. 
C520 S-c 
254,4 - 
30 
min 
F101 
F503 
F504 
2,58 A 
Normal operating. 
Input current stabilised at 2,57A. 
No component damaged. 
No hazard. 
D505 
S-c 
254,4 
AC - + 
30 min 
F101 
F505 
F506 
2,74 A 
Fan stopped immediately. 
Unit shut down after 17 min. 
Input current stabilised at 0,04A. 
F506 opened. 
No hazard. 
C517 S-c 
254,4 - 
30 
min 
F101 
F505 
F506 
2,53 A 
Fan stopped immediately. 
Unit shut down after 15 min. 
Input current stabilised at 0,04A. 
F505 opened. 
No hazard. 
IC54 
S-c 
254,4 
In - G 
30 min 
F101 
F505 
F506 
2,86 A 
Fan stopped immediately. 
Unit shut down after 14 min. 
Input current stabilised at 0,04A. 
F505 opened. 
No hazard. 
C521 S-c 
207  - 
30 
min 
F101 
F505 
F506 
2,60 A 
Fan stopped immediately. 
Unit shut down after 18 min. 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 37 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C521 S-c 
254,4 - 
30 
min 
F101 
F505 
F506 
2,64 A 
Fan stopped immediately. 
Unit shut down after 14 min. 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard. 
D104 
S-c 
254,4 
A - C 
9 min 
2,73 A 
Sub transformer primary winding 
heated up to 131K and thermal fuse 
opened after 9 min. 
Dielectric strength test OK. 
No hazard. 
C112 
S-c 
254,4 
7 min 
0,13 A 
Output signal off immediately. 
Sub transformer primary winding 
heated up to 130K and thermal fuse 
opened after 7 min. 
Dielectric strength test OK. 
No hazard. 
IC11 
S-c 
254,4 
In - G 
1 hr. 
0,07 A 
Output signal off immediately. 
Sub transformer primary winding 
heated up to 105K and stabilised. 
Dielectric strength test OK. 
No hazard. 
C116 
S-c 
254,4 
8 min 
0,09 A 
Output signal off immediately. 
Sub transformer primary winding 
heated up to 124K and thermal fuse 
opened after 8 min. 
Dielectric strength test OK. 
No hazard. 
D201 
S-c 
207 
AC - + 
1 sec. 
F101 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
No hazard. 
D201 
S-c 
254,4 
AC - + 
1 sec. 
F101 
F101 opened immediately. 
Input current stabilised at 0,04A. 
No hazard. 
C201 
S-c 
207 
10 min 
F101 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard. 
C201 
S-c 
254,4 
10 min 
F101 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 38 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C103 
S-c 
254,4 
30 min. 
F101 
2,66 A 
FL display off immediately. 
Input current stabilised at 2,49A. 
R104 damaged. 
No hazard. 
Q101 
S-c 
254,4 
B - C 
30 min 
F101 
2,61 A 
Normal operating. 
Input current stabilised at 2,61A. 
No component damaged. 
No hazard. 
C104 
S-c 
207 
40 min 
F101 
2,52 A 
FL display off immediately. 
Input current stabilised at 2,50A. 
R104 damaged. 
No hazard. 
C104 
S-c 
254,4 
1 hr 
F101 
2,64 A 
FL display off immediately. 
Input current stabilised at 2,55A. 
R104 damaged. 
No hazard. 
Speaker 
terminal 
(Front) 
S-c 
254,4 
R - G 
10 min 
F101 
Unit shut down immediately. 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard. 
Cover 
opening 
Blocked 
254,4 
Top 
5 hr 
F101 
2,61 A 
Normal operating. 
The components are heated up to: 
- Main transf. pr. winding  : 69K 
- Main transformer core  : 50K 
- Sub transf. pr. winding  : 62K 
- Sub transformer core 
: 44K 
- PWB near D201 
: 36K 
- Q318 body 
 
: 61K 
- PWB near Q318 
: 38K 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
Cover 
opening 
Blocked 254,4  Sides, 
Back 
5 hr 
F101 
2,61 A 
Normal operating. 
The components are heated up to: 
- Main transf. pr. winding  : 79K 
- Main transformer core  : 61K 
- Sub transf. pr. winding  : 76K 
- Sub transformer core 
: 60K 
- PWB near D201 
: 56K 
- Q318 body 
 
: 59K 
- PWB near Q318 
: 44K 
and stabilised. 
Dielectric strength test OK. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 