Harman Kardon AVR 630 (serv.man4) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 39 of 39 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
Fan 
Locked 
254,4 
15 min. 
F101 
2,61 A 
Unit shut down after 10 min. 
Input current stabilised at 0,04A. 
No component damaged. 
No hazard. 
Pmax 
operat. 
Maximum 
non-
clipped 
output 
signal 
254,4 
22 min. 
F101 
5,68 A 
The components are heated up to: 
- Main transf. pr. winding  : 141K 
- Main transformer core 
: 73K 
- Sub transf. pr. winding 
: 61K 
- Sub transformer core 
: 45K 
- PWB near D201 
: 63K 
- Q318 body 
: 59K 
- PWB near Q318 
: 43K 
and main transformer thermal fuse 
opened after 22 min. 
Dielectric strength test OK. 
No hazard. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998    -
 
- Page 1 of 3 - 
 
 
   
 Order 
No. 
14438
 
 
 
APPENDIX   
CENELEC EN 60065:1998 
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL 
DEVIATIONS AND OTHER INFORMATION     
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
 DE 
= Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = Sweden. 
P = Pass, F = Fail, = Not applicable.   
1.1.1 C 
Replace text in Note 1 by : This 
standard can be used as a guide for 
the testing of battery operated 
apparatus.  
 
2.6.1 S 
(DK)    Class I apparatus provided 
with a plug not establishing earthing 
continuity when inserted in Danish 
socket-outlets, see 15.1.1. 
 
Class II apparatus 
3.1 C 
Delete the note. Add the following 
indent : exposure to excessive 
sound pressures from headphones 
or earphones. 
 
 
 
D 
(DE) Marking in case of intrinsically 
ionizing radiation, cathode-ray tubes 
 
D 
(IT) Marking and instruction 
requirements  
- power consumption (W) for TV 
receivers  
 
6.1 D 
(DE) Limits for ionizing radiation, TV 
receivers (max. 1
µ
Sv/h) 
 
15.1.1 C 
Delete notes 1 and 2. 
Add to note 4: Attention is drawn to 
the fact that a standard is under 
preparation (presently prEN 50074) 
for socket-outlets which allow 
connection of Class II appliances 
only.  
 
 
15.1.1 S 
(DK) Mains plug according to Heavy 
Current Regulations, Section 107-2-
D1 
(DK) Mains socket outlets Cl.I 
(DK) Mains socket outlets Cl.II 
Not supplied with a cord set, See summary of testing. 
15.1.1 S 
(IE) Mains plug, flexible cord, 
according to statutory Instrument 
525: 1997 
Not supplied with a cord set, See summary of testing. 
15.1.1 S 
(NO) Mains socket outlets CI.II 
 
15.1.1 S 
(GB) Mains plug, flexible cord, 
according to statutory Instrument 
1768: 1994 
Not supplied with a cord set, See summary of testing. 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998    -
 
- Page 2 of 3 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
15.2 C 
Delete note 2
 
 
 
16.1 C 
Delete note 1
 
 
 
16.2 C 
Delete the note 
 
 
 
20 C 
Delete note 2
 
 
 
 
APPENDIX 
ANNEX B (normative) 
 
No TNV circuit 
Annex B C 
Delete note 2 
 
 
B.5.4.1  S 
(NO) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
 
Applicable text is: 
"Apparatet må kun tilkoples jordet 
stikkontakt" or   
"Jordet stikkontakt skal benyttes når 
apparatet tilkoples datanett" 
Swedish text can also be accepted. 
 
 
B.5.4.1  S 
(SE) Marking stating that the 
apparatus must be connected to an 
earthed mains socket outlet. 
 
The marking text shall be in Swedish 
and as follows: 
"Apparaten skall anslutas till jordat 
uttag när den ansluts till ett nätverk"   
 
 
B.5.4.1 e) C 
Delete notes 1 and 2 
 
 
B.8.1 C 
Delete notes 1, 2 and 3 
 
 
B.8.1 S 
(DK) Method b) is permitted only for 
PERMANENTLY CONNECTED 
APPARATUS 
 
 
B.8.1 S 
(NO) Method b) is not permitted 
 
 
B.8.2 C 
Delete the note 
 
 
B.14.12 C 
Delete notes 1 and 2 
 
 
B.14.12 S 
(DK) The following note is added: 
NOTE in Denmark the use of surge 
suppressors between the 
TELECOMMUNICATION 
NETWORK and conductive 
ACCESSIBLE parts or TERMINALS 
which are considered to be 
ACCESSIBLE, is allowed only for 
PERMANENTLY CONNECTED 
APPARATUS. 
 
 
 
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998    -
 
- Page 3 of 3 - 
 
 
   
 Order 
No. 
14438
 
 
 
 
B.14.12 S 
(NO) The following note is added: 
NOTE in Norway, for Class I apparatus 
intended to be connected to the MAINS 
by means of a plug, surge suppressors 
may only be connected between TNV 
circuits and ACCESSIBLE parts if the 
apparatus has a marking stating that it 
must be connected to an earthed 
MAINS socket outlet. 
 
 
B.14.12 S 
(SE) The following note is added: 
NOTE in Sweden, for Class I apparatus 
intended to be connected to the MAINS 
by means of a plug, surge suppressors 
may only be connected between TNV 
circuits and ACCESSIBLE parts if the 
apparatus has a marking stating that it 
must be connected to an earthed 
MAINS socket outlet. 
 
The marking text shall be in Swedish 
and as follows: 
"Apparaten skall anslutas till jordat 
uttag." 
 
 
APPENDIX 
ANNEX G (normative) 
 
 
 
Annex G C 
Delete the note 
 
 
APPENDIX 
ANNEX P (informative) 
 
 
 
Annex P C 
Add the following notes for the 
standards indicated : 
IEC 60130 : 
NOTE: IEC 60130-9:1989 + A1:1993 
are harmonized as EN 60130-9 (not 
modified). 
IEC 60169 : 
NOTE: Parts 23, 24 and 25 are 
harmonized as Ens (not modified). 
IEC 60173 :   
NOTE: Harmonized as HD 27 S1:1983 
(not modified). 
IEC 60260 :   
NOTE: Harmonized as HD 98 S1:1977 
(not modified). 
IEC 60335-2-56 : 
NOTE: Harmonized as EN 60335-2-56: 
1997 (not modified). 
IEC 61040 : 
NOTE: Harmonized as EN 61040: 1992 
(not modified). 
IEC 60695 : 
NOTE: Harmonized as EN 60695 
series (not modified). 
 
 
 
Page of 48