Harman Kardon AVR 430 (serv.man18) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 23 of 38 -
Order
No.
14437
14.6.10
Surge current for mains switches
also controlling mains socket-outlets
also controlling mains socket-outlets
Measured surge current through,
- Mains relay = 48 A. + 20 A* = 68 A total
- Mains switch = < 2 A.
*) Surge current value for switched outlet, 50W = 20 A.
The measured and calculated surge current value is less
than rated surge current rating. OK.
- Mains relay = 48 A. + 20 A* = 68 A total
- Mains switch = < 2 A.
*) Surge current value for switched outlet, 50W = 20 A.
The measured and calculated surge current value is less
than rated surge current rating. OK.
P
14.7 Safety
interlocks
N
Safety interlocks to 2.8 of
IEC 60 950
IEC 60 950
No safety interlock
N
14.8
Voltage setting devices
N
Voltage setting device not likely to be
changed accidentally
changed accidentally
No voltage selector
N
14.9 Motors
Only secondary DC low voltage motors for fan. No special
testing is considered necessary for these motors
testing is considered necessary for these motors
N
14.9.1
Endurance test on motors
N
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or
grease etc.
grease etc.
N
14.9.3
Protection against moving parts
No moving parts
N
14.9.4
Motors with phase-shifting
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
capacitors, three-phase motors and
series motors meet Cl. B.8, B.9 and
B.10 of IEC 60 950, Annex B
N
14.10 Batteries
N
14.10.1
Batteries mounted with no risk of
accumulation of flammable gases
accumulation of flammable gases
No batteries
N
14.10.2
No possibility of recharging non-
rechargeable batteries
rechargeable batteries
N
14.10.3
Recharging currents and times
within manufacturers limits
within manufacturers limits
N
Lithium batteries discharge and
reverse currents within the
manufacturers limits
reverse currents within the
manufacturers limits
N
14.11 Optocouplers
N
Optocouplers comply with Cl. 8
No optocouplers.
N
Internal and external dimensions to
13.1.1
13.1.1
N
-
IEC 60065, 6th edition : 1998
-
- Page 24 of 38 -
Order
No.
14437
15 TERMINALS
P
15.1.1
Mains plug, appliance inlet,
interconnection couplers and mains
socket-outlet meet the appropriate
standard
interconnection couplers and mains
socket-outlet meet the appropriate
standard
See list below.
P
Component Manufacturer
Type
Standard
Certified
Remarks
sheet
by
(colour
etc.)
Appliance inlet
Zhangjiagang
Huajie Electronics.
Huajie Electronics.
SA-4S
IEC 60320-1
VDE
10A 250V~, black
Mains socket- outlet
Dae Ryung Elect.
A3-04-D007
IEC 60884-1
NEMKO
2.5A 250V~, black
Mains sockets and interconnection
couplers
couplers
The socket outlet on the Class II apparatus does only
permit connection of other Class II apparatus.
permit connection of other Class II apparatus.
P
Overload protection for
socket-outlets
socket-outlets
Overload protection provided with a fuses,
F1, T2A 250V
F1, T2A 250V
P
15.1.2
Connectors for antenna, earth,
audio, video or data:
audio, video or data:
P
No risk of insertion in mains
socket-outlets
socket-outlets
Only phono/RCA, Optical, Antenna, RS-232C, A-BUS,
Mini jack and S-video terminals used. Banana plug type
speaker terminal also used, but they are accepted due to
below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
Mini jack and S-video terminals used. Banana plug type
speaker terminal also used, but they are accepted due to
below note.
Note:
Banana plug type speaker terminals are blocked in their
axial holes to prevent use of plugs that can make
permanent contact with a mains socket outlet.
P
Sockets for audio and video circuits
indicated with the symbol of 5.2.b.
indicated with the symbol of 5.2.b.
No sockets indicated with the symbol
N
15.1.3
Output terminals of AC adaptors or
similar devices not compatible with
household mains socket-outlets
similar devices not compatible with
household mains socket-outlets
N
15.2
Provision for protective earthing
Class II apparatus
N
Accessible conductive parts of
Class I equipment reliably connected
to earth terminal, within equipment.
Class I equipment reliably connected
to earth terminal, within equipment.
N
Switches or fuses in protective earth
circuits
circuits
N
Class I supply apparatus with non-
hazardous live output voltage: output
circuit not connected to earth
hazardous live output voltage: output
circuit not connected to earth
N
Protective earth conductors correctly
coloured
coloured
N
-
IEC 60065, 6th edition : 1998
-
- Page 25 of 38 -
Order
No.
14437
Permanently connected apparatus
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
and apparatus with non-detachable
mains cord provided with separate
protective earth terminal near mains
input
N
Protective earth connection of a part
removable by hand.
removable by hand.
N
Protective earth terminal resistant to
corrosion
corrosion
N
Earth resistance (
Ω
) test:
≤
0,1
Ω
at
25 A
N
15.3.
Terminals for external flexible cords
and for permanent connection to the
mains supply
and for permanent connection to the
mains supply
Appliance inlet applied
N
15.3.1
Adequate terminals for connection of
permanent wiring
permanent wiring
N
15.3.2
Reliable connection of non-
detachable cords:
detachable cords:
N
Connection of the non-detachable
cord
cord
N
Soldered to conductors of a printed
circuit board
circuit board
N
Adequate clearances and creepage
distances between connections
should a wire break away
distances between connections
should a wire break away
N
Wire secured by additional means
N
15.3.3
Screws and nuts clamping external
mains supply conductors have
adequate threads: ISO 261, ISO 262
or similar
mains supply conductors have
adequate threads: ISO 261, ISO 262
or similar
N
15.3.4
Soldered conductors wrapped
around terminal prior to soldering or
held in place by additional means
around terminal prior to soldering or
held in place by additional means
N
Clamping of conductor and
insulation if not soldered or held by
screws
insulation if not soldered or held by
screws
N
15.3.5
Terminals for external flexible cords
shall allow connection of appropriate
cross-sectional area of conductors
for the rated current of the
equipment
shall allow connection of appropriate
cross-sectional area of conductors
for the rated current of the
equipment
N
15.3.6
Terminals to 15.3.3 have sizes
required by Table 8
required by Table 8
N
-
IEC 60065, 6th edition : 1998
-
- Page 26 of 38 -
Order
No.
14437
15.3.7
Terminals clamp conductors
between metal surfaces
between metal surfaces
N
Terminals designed to avoid
conductor slipping out when
tightened or loosened
conductor slipping out when
tightened or loosened
N
Terminals adequately fixed to avoid
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
loosening when the clamping is
tightened or loosened and stress on
internal wiring is avoided
N
15.3.8
Terminals carrying a current more
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
than 0,2 A: contact pressure not
transmitted by insulating material
except ceramic
N
15.3.9
Termination of non-detachable
cords: wires terminated near to each
other
cords: wires terminated near to each
other
N
Terminals located and shielded: test
with 8 mm strand
with 8 mm strand
N
15.4
Devices forming a part of the mains
plug
plug
The apparatus is not a device forming a part of the
mains plug.
mains plug.
N
15.4.1
No undue strain on mains socket-
outlets
outlets
N
15.4.2
Device complies with standard for
dimensions of mains plugs
dimensions of mains plugs
N
15.4.3.
Device has adequate mechanical
strength (tests a,b,c)
strength (tests a,b,c)
N
16
EXTERNAL FLEXIBLE CORDS
P
16.1
Mains cords sheathed type,
complying with IEC 60 227 for PVC
or IEC 60 245 for synthetic rubber
cords
complying with IEC 60 227 for PVC
or IEC 60 245 for synthetic rubber
cords
Appliance inlet, cord-set not supplied for testing.
See summary of testing.
See summary of testing.
N
Mains cord
Manufacturer
Marking
Cross-
Certified by
(type)
sectional
area
(mm2)
Non-detachable cords for Class I
have green/yellow core for protective
earth
have green/yellow core for protective
earth
N
16.2
Mains cords conductors have
adequate cross-sectional area for
rated current consumption of the
equipment
adequate cross-sectional area for
rated current consumption of the
equipment
N
Click on the first or last page to see other AVR 430 (serv.man18) service manuals if exist.