Harman Kardon AVR 430 (serv.man18) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 19 of 38 -
Order
No.
14437
Transformer/motor Insulation
Insulation
Test
Flashover
Creepage
distances
Part No/markings
between
resistance
voltage
Breakdown
and clearances
M Ohm
kV(60)s
voltage kV
Measured
Required
H01-TX-PWM-MD01-B0
Pr - sec
> 100
3KV (rms)
-
12,3 mm
≥≥≥≥
6 mm
Pr - ic
> 100
3KV (rms)
-
10,3 mm
≥≥≥≥
6 mm
H01-TX-PWM-SD02-A0
Pr - sec
> 100
3KV (rms)
-
6,4 mm
≥≥≥≥
6 mm
Pr - ic
> 100
3KV (rms)
-
6,2 mm
≥≥≥≥
6 mm
Components / construction
(H01-TX-PWM-MD01-B0)
Windings on two separate bobbins. The bobbins are
placed in an insulating housing with two compartments,
one above the other. Bobbin thickness: > 0,4mm.
placed in an insulating housing with two compartments,
one above the other. Bobbin thickness: > 0,4mm.
P
Components / construction
(H01-TX-PWM-SD02-A0)
Windings on single bobbins. A wall (2 layers) is provided
between primary and secondary windings. Satisfactory
constructed. Bobbin thickness: > 0,4mm.
between primary and secondary windings. Satisfactory
constructed. Bobbin thickness: > 0,4mm.
P
Transformer/motor
Insulation
Thickness (mm)
Material
Dielectric strength test
Part No/markings
between
X
for each combination of
Number
two (2) layers
H01-TX-PWM-MD01-B0
Pr - sec
0,80 mm min. x 1
PBT bobbin
Pass *)
Pr - ic
0,80 mm min. x 1
PBT bobbin
Pass *)
H01-TX-PWM-SD02-A0
Pr - sec
0,40 mm min. x 2
0,40 mm min. x 1
0,40 mm min. x 1
PET bobbin wall
66 Nylon bobbin cap.
66 Nylon bobbin cap.
Pass *)
Pr - ic
0,60 mm min. x 1
PET bobbin
Pass *)
Pr - ic
0,40 mm min. x 1
66 Nylon bobbin cap.
Pass *)
*) Test voltage: 3000 Vrms.
14.3.4.1
Class II transformers have adequate
separation between hazardous live
windings and windings intended to
be connected to accessible
conductive parts (double or
reinforced insulation)
separation between hazardous live
windings and windings intended to
be connected to accessible
conductive parts (double or
reinforced insulation)
Double or reinforced insulation between primary and
secondary windings according to clause 8.8.
secondary windings according to clause 8.8.
P
Coil formers and partition walls
≥
0,4 mm
The bobbin fulfils the requirement of reinforced insulation,
see table above for bobbin thickness.
see table above for bobbin thickness.
P
14.3.4.2
Class I transformers, with basic
insulation and protective screening
only if all 7 conditions of 14.3.4.2 are
met
insulation and protective screening
only if all 7 conditions of 14.3.4.2 are
met
N
14.3.4.3
Separating transformers with at least
basic insulation
basic insulation
N
-
IEC 60065, 6th edition : 1998
-
- Page 20 of 38 -
Order
No.
14437
14.3.5.1
Class II transformers have adequate
insulation between hazardous live
parts and accessible parts (double or
reinforced insulation)
insulation between hazardous live
parts and accessible parts (double or
reinforced insulation)
Double or reinforced insulation between hazardous live
windings and accessible conductive parts.
windings and accessible conductive parts.
P
Coil formers and partition walls
≥
0,4 mm
The bobbin fulfils the requirement of reinforced insulation,
see table above for bobbin thickness.
see table above for bobbin thickness.
P
14.3.5.2
Class I transformers have adequate
insulation between hazardous live
parts and accessible conductive
parts or those conductive parts or
protective screens connected to a
protective earth terminal
insulation between hazardous live
parts and accessible conductive
parts or those conductive parts or
protective screens connected to a
protective earth terminal
N
Winding wires connected to
protective earth have adequate
current-carrying capacity
protective earth have adequate
current-carrying capacity
N
14.4
High voltage components
N
High-voltage components and
assemblies: U > 4 kV (peak)
separately approved
assemblies: U > 4 kV (peak)
separately approved
No high voltage components used
N
Component meets category FV 1 of
IEC 60 707
IEC 60 707
N
14.4.1
High voltage transformers and
multipliers tested as part of the
submission
multipliers tested as part of the
submission
N
14.5 Protective
devices
P
Protective devices used within their
ratings
ratings
Yes,
Thermal link and fuse
Thermal link and fuse
P
External clearance and creepage
distances appropriate for the voltage
across the device when opened
distances appropriate for the voltage
across the device when opened
Adequate external clearance and creepage distance
P
14.5.1.1
a) Thermal cut-outs separately
approved
approved
None
N
b) Thermal cut-outs tested as part of
the submission
the submission
N
14.5.1.2
a) Thermal links separately
approved
approved
a) Mains transformer (Mfr. / type):
FUJI Terminal Industry Co., Ltd. / S154
Certified by: VDE according to IEC60691
b) Sub. Transformer (Mfr. / type):
Anzen Dengu Co., Ltd. / K13
Certified by: VDE according to IEC60691
P
b) Thermal links tested as part of the
apparatus
apparatus
N
14.5.1.3
Thermal devices resettable by
soldering
soldering
No such thermal device
N
-
IEC 60065, 6th edition : 1998
-
- Page 21 of 38 -
Order
No.
14437
14.5.2.1
Fuse-links in the mains circuit
according to IEC 60 127
according to IEC 60 127
See list below
P
Circuit Manufacturer
Dimen-
Approved
Marking
of
Marking
Current
diagram
sions
by
rated current,
close to
through
informa-
pre-arcing time
the com-
the fuse
tion
and current
ponent
in normal
Part No
characteristic
operation
F1 (pr.)
Orisel Co., Ltd.
5
××××
20 mm
VDE
T 2A L 250V
T 2A L 250V
0,65 A *)
F101 (pr.)
Orisel Co., Ltd.
5
××××
20 mm
VDE
T5A L 250V
T5A L 250V
2,40 A
F501, F502 (sec.)
Save Fusetech Inc. 7.7x8.3x4 mm
TUV
T2A 250V
T 2A L 250V
0,53 A
F503, F504 (sec.)
Save Fusetech Inc. 7.7x8.3x4 mm
TUV
T2A 250V
T 2A L 250V
0,91 A
F505, F506 (sec.)
Save Fusetech Inc. 7.7x8.3x4 mm
TUV
T2A 250V
T 2A L 250V
0,44 A
*) Calculated through current for mains socket-outlet: SWITCHED, 50W + UNSWITCHED, 100W
14.5.2.2
Correct marking of fuse-links
adjacent to holder
adjacent to holder
Correct marking applied close to the fuse, see table
above.
above.
P
14.5.2.3
Not possible to connect fuses in
parallel
parallel
No fuse holder so designed that fuse-links can be
connected in parallel
connected in parallel
P
14.5.2.4
Not possible to touch hazardous
live parts when replacing fuse-
links without the use of a tool
live parts when replacing fuse-
links without the use of a tool
No replacement of fuse possible by hand.
P
14.5.3
PTC-S thermistors comply with
IEC 60 738
IEC 60 738
No PTC’s
N
PTC-S devices (>15 W)
category FV 1 or better
category FV 1 or better
N
14.5.4
Other protective devises.
Circuit protectors have
adequate breaking capacity and
their position is correctly marked
Circuit protectors have
adequate breaking capacity and
their position is correctly marked
No other protective devices
N
14.6 Switches
P
Manually operated mechanical
switch (MOMS) conductively
connected to the mains
switch (MOMS) conductively
connected to the mains
P
Part No
Function
Manufacturer
Type
Rated
Marking
Marking
All-
One
Name
Trademark
V
A
Surge
pole
pole
current
-
x
Alps Electric Co., Ltd.
-
SDL1P-D
250
5
80A
SK11 x Tyco
Electronics.
OEG
SDT-S-112DMR
250 8
120A
-
IEC 60065, 6th edition : 1998
-
- Page 22 of 38 -
Order
No.
14437
14.6.1
Permanently connected equipment
provided with an all-pole mains
switch unless 5.4.2 is met
provided with an all-pole mains
switch unless 5.4.2 is met
Apparatus is not permanently connected
N
14.6.2
Manually operated mechanical
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
switch (MOMS), required where
power consumption > 15 W and/or
peak voltage > 4 kV
Yes. MOMS required. See table above.
P
Switch readily accessible and not in
mains cord
mains cord
Switch located on the front and readily accessible
P
Exception for automatic switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical
switch (MOMS): Switch indication /
On position clearly discernible
switch (MOMS): Switch indication /
On position clearly discernible
The display is illuminated.
P
Indication by marking meets Cl. 5
Yes
P
Indication of the OFF position
Off-position marked with “OFF”
P
14.6.4
Manually operated mechanical
switch (MOMS) fitted. Is there a
Stand-by mode
switch (MOMS) fitted. Is there a
Stand-by mode
Yes
P
Stand-by mode clearly discernible
LED indication
P
Exception for low Stand-by current
< 0,7 mA (peak)
< 0,7 mA (peak)
N
14.6.5
Components bridging contacts of
mains switches comply with 14.1 a)
or 14.2.2
mains switches comply with 14.1 a)
or 14.2.2
Yes, relay for C118.
See also clause 14.2.
See also clause 14.2.
P
14.6.6.a.
Manually operated mechanical
switches (MOMS) separately
approved to IEC 61 058-1
switches (MOMS) separately
approved to IEC 61 058-1
Yes.
- Mains switch, certified by VDE,
- Mains relay, certified by SEMKO.
- Mains switch, certified by VDE,
- Mains relay, certified by SEMKO.
P
14.6.6.b.
Manually operated mechanical
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
switch (MOMS) tested as part of the
equipment complies with 14.6.7,
14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
Flame test for mains switches
N
14.6.7 Endurance
test
N
14.6.8
Temperature rise in mains switch
N
14.6.9
Dielectric strength test
N