Harman Kardon AVR 270 (serv.man6) EMC - CB Certificate ▷ View online
Reference No. : 54121209A Page 9/43
◀ Anam EMC Test Laboratory ▶
6.5. Test protocols
Date: September 3, 2012
Disturbance radiation due to the local oscillator.
Disturbance radiation due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit
(㏈㎶/m)
Disturbance value(㏈㎶/m)
Horizon Vertical
1
98.2
60.0
* *
2
196.4
52.0
* *
3
294.6
52.0
* *
4
392.8
56.0
* *
87.5 5 491.0
56.0 * *
6
589.2
56.0
* *
7
687.4
56.0
* *
8
785.6
56.0
* *
9
883.8
56.0
* *
10
982.0
56.0
* *
1
108.7
60.0
* *
2
217.4
52.0
* *
3
326.1
56.0
* *
98.0 4 434.8
56.0 * *
5
543.5
56.0
* *
6
652.2
56.0
* *
7
760.9
56.0
* *
8
869.6
56.0
* *
9
978.3
56.0
* *
1
118.7
60.0
* *
2
237.4
52.0
* *
3
356.1
56.0
* *
108.0 4 474.8
56.0 * *
5
593.5
56.0
* *
6
712.2
56.0
* *
7
830.9
56.0
* *
8
949.6
56.0
* *
Reference No. : 54121209A Page 10/43
◀ Anam EMC Test Laboratory ▶
Disturbance radiation due to the other source.
Channel Harmonic
Measured
freq. (㎒)
Limit
(㏈㎶/m)
Disturbance value(㏈㎶/m)
Horizon Vertical
122.28
40.0
*
29.2
Others 159.75
40.0 27.8 *
208.89
40.0
32.4
28.7
30
~
221.18
40.0
33.7 28.3
1,000 ㎒
479.23
47.0
34.6 33.8
606.40
47.0
* 38.2
*: More than margin 7.0 ㏈㎶/m
Limit according to EN55013:2001+A2(2006)
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE
FREQUENCY RANGE 30MHz TO 1,000MHz
7.1. Operating environment
Temperature
: 28℃
Relative humidity : 37%
7.2. Test set-up and procedure
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒.
The level of the test signal, which was connected to the receiver through a
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
7.3. Measurement uncertainty
Antenna terminal disturbance voltage, Quasi-peak detection: ±2.0 ㏈
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.
Reference No. : 54121209A Page 11/43
◀ Anam EMC Test Laboratory ▶
7.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Measurement
Receiver
Receiver
R & S
ESCI
100348
Signal Generator
Anritsu
MG3632A
MT79870
Combining network
Municom
MCL ZFSC-2-11
N
N
942604
Matching pad
(50~75Ω)
(50~75Ω)
R & S
RAM 358
837254/004
* R & S: Rohde & Schwarz
Reference No. : 54121209A Page 12/43
◀ Anam EMC Test Laboratory ▶
7.5. Test protocols
Date: September 3, 2012
Antenna terminal disturbance voltage due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
1
98.2
54.0
*
2
196.4
50.0
*
3
294.6
50.0
*
4
392.8
52.0
*
87.5 5 491.0
52.0 *
6
589.2
52.0
*
7
687.4
52.0
*
8
785.6
52.0
*
9
883.8
52.0
*
10
982.0
52.0
*
1
108.7
54.0
*
2
217.4
50.0
*
3
326.1
52.0
*
98.0 4 434.8
52.0 *
5
543.5
52.0
*
6
652.2
52.0
*
7
760.9
52.0
*
8
869.6
52.0
*
9
978.3
52.0
*
1
118.7
54.0
*
2
237.4
50.0
*
3
356.1
52.0
*
108.0 4 474.8
52.0 *
5
593.5
52.0
*
6
712.2
52.0
*
7
830.9
52.0
*
8
949.6
52.0
*
Click on the first or last page to see other AVR 270 (serv.man6) service manuals if exist.