Harman Kardon AVR 270 (serv.man6) EMC - CB Certificate ▷ View online
Reference No. : 54121209A Page 21/43
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
03.Sep 12 19:01
RBW
9 kHz
MT
1 s
PREAMP OFF
Att 25 dB
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
58.75 dBµV
8.442000000 MHz
A4_AV
A4_QP
AVR270/230_Ground line2(1KHz sine wave input at FM87.5MHz)
Date: 3.SEP.2012 19:01:53
Reference No. : 54121209A Page 22/43
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
03.Sep 12 19:07
RBW
9 kHz
MT
1 s
PREAMP OFF
Att 25 dB
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
54.44 dBµV
8.450000000 MHz
A4_AV
A4_QP
AVR270/230_Nonground line1(1KHz sine wave input at FM87.5MHz
)
Date: 3.SEP.2012 19:07:25
Reference No. : 54121209A Page 23/43
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
03.Sep 12 19:12
RBW
9 kHz
MT
1 s
PREAMP OFF
Att 25 dB
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
59.84 dBµV
8.306000000 MHz
A4_AV
A4_QP
AVR270/230_Nonground line2(1KHz sine wave input at FM87.5MHz
)
Date: 3.SEP.2012 19:12:40
Reference No. : 54121209A Page 24/43
◀ Anam EMC Test Laboratory ▶
6DB
ANAM EMC Testing Lab.
150 kHz
30 MHz
dBµV
dBµV
1 PK
CLRWR
2 AV
CLRWR
SGL
RBW
9 kHz
MT
1 s
PREAMP OFF
Att 25 dB
03.Sep 12 18:50
1 MHz
10 MHz
-10
0
10
20
30
40
50
60
70
80
90
1
Marker 1 [T1 ]
54.54 dBµV
8.278000000 MHz
A4_AV
A4_QP
AVR270/230_Nonground line1(1KHz sine wave input at Analog2)
Date: 3.SEP.2012 18:50:15
Click on the first or last page to see other AVR 270 (serv.man6) service manuals if exist.