Harman Kardon AVR 270 (serv.man6) EMC - CB Certificate ▷ View online
Reference No. : 54121209A Page 5/43
◀ Anam EMC Test Laboratory ▶
3. TEST SPECIFICATIONS
3.1. Standards
*EN55013 (2001)&A1(2003)+A2(2006) :
Sound and Television broadcast receivers and Associated equipment
-Radio Disturbance characteristics - Limits and methods of measurement.
-Radio Disturbance characteristics - Limits and methods of measurement.
3.2. Additions, deviations and exclusions from standard
No additions, deviations or exclusions have been made from standard.
3.3. Purpose of the test:
To determine whether the EUT fulfils the EMC-emission requirements of the
Standards stated in section 3.1.
3.4. Mode of operation during the test
The EUT was operated in such a way as to deliver one-eighth on the non-clipped
output power to the rated load impedance using the sinusoidal of 1 ㎑ & color-
bar.
The EUT was set to the mode of Tuner.
4. TEST SUMMARY
The results in this report apply only to sample(s) tested:
Test item
Passed
the test
Note
Mains terminal disturbance voltage
Yes
Disturbance Radiation
Yes
Antenna Terminal Disturbance Voltage
Yes
Disturbance Power
Yes
The equipment does comply with the requirements.
For the measurement data, see Annex.
Reference No. : 54121209A Page 6/43
◀ Anam EMC Test Laboratory ▶
5. MAINS TERMINAL DISTURBANCE VOLTAGE IN THE FREQUENCY
RANGE 0.15MHz TO 30MHz
5.1. Operating environment
Temperature
: 27℃
Relative humidity : 37 %
5.2. Test set-up and procedure
The mains terminal disturbance voltage was measured with the EUT in a
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
Screened room. The EUT was placed on a non-metallic table by 0.8m above
the metallic grounded floor and 0.4m from the reference ground panel (RGP)
wall. The distance to other metallic surfaces was at least 0.8m.
The EUT was tested with the outer conductor of the antenna input connected
as well as not connected to the ground terminal of the AMN.
The level of the test signal was 500mV (1 KHz) at coaxial RF input connector.
Amplitude measurements were performed with a quasi-peak detector and,
If required, with an average detector.
5.3. Measurement uncertainty
Mains terminal disturbance voltage, quasi-peak detection: ±2.0dB
Mains terminal disturbance voltage, average detection : ±2.0dB
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.
Reference No. : 54121209A Page 7/43
◀ Anam EMC Test Laboratory ▶
5.4. Test instrument
Equipment
Manufacturer
Type No.
Serial No.
Test site
Shielded room
-
-
Measurement
Receiver
Receiver
R & S
ESCI
100348
Artificial mains
Network
Network
R & S
ESH3-Z5
844249/020
EMCO 3825/2 90101718
Test Compact Disc
Abex
TCD-782
N/A
R. C. Oscillator
Kenwood
AG-203A
3090241
Signal Generator
Anritsu
MG3632A
MT79870
* R & S: Rohde & Schwarz
5.5. Test protocol
Date: September 3, 2012
Grounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A.
report as Annex A.
Mode
Freq.
(㎒)
Quasi-peak (㏈㎶) Average
(㏈㎶)
Limit
Disturbance value
Limit
Disturbance value
Line 1
Line 2
Line 1
Line 2
Tuner
8.278 60.0 50.0 54.4 50.0 44.8 48.8
Ungrounded at the Signal GND Terminal on the Rear Enclosure.
An overview sweep performed with peak detector is included in the test
report as Annex A
report as Annex A
Mode
Freq.
(㎒)
Quasi-peak (㏈㎶) Average
(㏈㎶)
Limit
Disturbance value
Limit
Disturbance value
Line 1
Line 2
Line 1
Line 2
Tuner
8.278 60.0 49.7 54.4 50.0 44.4 48.7
Analog
2
0.150 66.0 53.6 51.4 56.0 43.8 42.9
8.278 60.0 49.8 54.5 50.0 44.5 48.8
The equipment does comply with the requirements.
For the measurement data, see Annex A (6 Copies).
Reference No. : 54121209A Page 8/43
◀ Anam EMC Test Laboratory ▶
6. DISTURBANCE RADIATION IN THE FREQUENCY RANGE 30MHz
TO 1,000MHz
6.1. Operating environment
Temperature
: 28℃
Relative humidity : 37%
6.2. Test set-up and procedure
The measurement was performed on an open area test site with a reference
ground plane and at a distance of 3m. The height of the measuring antenna was
varied between 1 to 4m and the table was rotated a full revolution in order to
obtain maximum value of the electric field intensity. The measurement was
made in both the vertical and horizontal polarization, and the maximum value is
presented in the report.
The measurement was performed with a quasi-peak detector.
Disturbance radiation due to the fundamental and harmonic frequencies of the
local oscillator and the other source were measured on a selected number of FM
sound broadcast channels. About the Disturbance radiation value from the other
source, the sixteen maximum values were recorded.
The test was measured with the main unit and the remote control unit.
obtain maximum value of the electric field intensity. The measurement was
made in both the vertical and horizontal polarization, and the maximum value is
presented in the report.
The measurement was performed with a quasi-peak detector.
Disturbance radiation due to the fundamental and harmonic frequencies of the
local oscillator and the other source were measured on a selected number of FM
sound broadcast channels. About the Disturbance radiation value from the other
source, the sixteen maximum values were recorded.
The test was measured with the main unit and the remote control unit.
6.3. Measurement uncertainty
Radiated disturbance electric field intensity, 30 ~ 300 ㎒: ±2.0 ㏈
Radiated disturbance electric field intensity, 300 ~ 1,000 ㎒: ±2.0 ㏈
The Measurement uncertainty describes the overall uncertainty of the given
measured value during operation of the EUT in the above-mentioned way.
measured value during operation of the EUT in the above-mentioned way.
6.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Test site
Open area test site
-
Measurement
Receiver
R & S
ESCI
100348
Signal Generator
Anritsu
MG3632A
MT79870
Test Compact Disc
Abex
TCD-782
N/A
Bi-conical Ant.
Schwarzbeck
VHA9103
9103 1135
Log-periodic Ant.
Schwarzbeck
UHALP 9108-A 91081098
Ant. Master
EMCO
1051-12
90121554
Turn table
EMCO
1080-1.211
90121504
Click on the first or last page to see other AVR 270 (serv.man6) service manuals if exist.