DOWNLOAD Harman Kardon AVR 270 (serv.man4) Service Manual ↓ Size: 2.49 MB | Pages: 57 in PDF or view online for FREE

Model
AVR 270 (serv.man4)
Pages
57
Size
2.49 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-270-sm4.pdf
Date

Harman Kardon AVR 270 (serv.man4) EMC - CB Certificate ▷ View online

 
Anam Electronics Co., Ltd.                                    Page 5 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
2.  Equipment Under Test ( EUT) 
 
2.1 Identification of EUT
 
       
Category: 
AV Receiver 
Model Name: 
AVR270/230 
Brand Name: 
Harman/Kardon 
Serial Number: 
N/A 
Rated Voltage: 
a.c. 220 – 240 V, 50/60 Hz, 370 W 
Tested Voltage: 
a.c. 230 V, 50 Hz 
External Signal 
IN/OUT: 
 
 
Analog Audio IN (4), Audio REC OUT (2), Audio Zone 2 OUT (2),   
IR IN (1), IR OUT (1), ZONE 2 IR IN (1), Trigger OUT (1),   
Digital Coaxial (1),Component Video (1), Composite Video IN/OUT (3),   
RS-232 (1), HDMI IN/OUT (9), SUB Woofer Pre-OUT (1),   
Network RJ45(1), Speakers (7), USB (1), Headphone (1) 
 
Clock: 
27.0 MHz (X1201), 27.0 MHz (X1401), 24.576 MHz (X4001), 
25.0 MHz (X2101), 24.0 MHz (X3900), 32.768 kHz (X1) 
 
Chipsets: 
ADV7850KBCZ (IC1201), ADV8003KBCZ (IC1401), CS497024 (IC1902),
CS42528 (IC2103), DM860A (IC390), SHDR100A (U2) 
 
Printed Circuit 
Boards(Part No.):
Front 
CUP12455Y 
Anam Elec. Co. 
Digital   
CUP12457Z 
Anam Elec. Co. 
Main 
CUP12459Z 
Anam Elec. Co. 
Jack 
CUP12460Z 
Anam Elec. Co. 
DM860A 
CUP12454Z 
Anam Elec. Co. 
Audio Pre Output 
CUP12443 
Anam Elec. Co. 
SMPS Power 
CUP12481Z 
Anam Elec. Co. 
Tuner 
Pack 
Module MW104FV1-S63V Kwang 
Sung 
Elec. 
Remarks: 
 
 
2.2 Variants Covered By This Report
 
     
 
ID No. 
Model Name 
Technical Deviations From Reference Model 
N/A N/A 
 
 
2.3  Modifications 
● No comment 
   
2.4  Additional Information Related To Testing 
●No comment 
   
2.5 Picture Documentation 
●Pictures can be found in 
Appendix B. 
 
Anam Electronics Co., Ltd.                                    Page 6 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
3.  General Test Conditions 
 
3.1 Location 
 
NEMKO KOREA                             
155 & 159, Osan-Ro, Mohyeon-Myeon, Cheoin-Gu, Yongin-Si, Gyeonggi-Do 449-852 KOREA,   
REPUBLC OF   
 Phone : + 82 31 330 1700       Fax : + 82 31 322 2332           
 
3.2 Operating Environment 
       
      All tests and measurements were performed in a shielded enclosure or a controlled environment 
      suitable for the tests conducted. The climatic conditions in the test area are automatically controlled   
   and recorded continuously. 
 
Parameters 
Recording during test 
Accepted deviation 
ESD Test 
Others Test 
ESD Test 
Others Test 
Ambient temperature 
(21.9 ~ 25.1)  ℃ 
(15.0 ~ 35.0)  ℃ 
Relative humidity 
56.0 % R.H. 
(55.0 ~ 60.0) % R.H. 
(30.0 ~ 60.0) % R.H.
(75.0 or less) % R.H.
Atmospheric pressure 
(99.8 ~ 100.3) kPa 
(86.0 ~ 106.0) kPa 
 
3.3 Operating During Test 
 
●The audio output signal of EUT was adjusted by the volume control to be 1/8 W of the rated Max. output   
power for each output and observed. 
The test was performed in USB memory and Network internet radio.         
 
3.4 Test Equipment 
       
●The test equipment used in testing are calibrated on a regular basis. For most of the testing equipment 
accredited calibration is conducted once a year. For certain equipment the calibration interval is 
longer. Between the calibrations all test equipment are controlled and verified on a regular basis. The 
test equipments used are defined in each test section of this report.             
 
3.5 Support Equipment 
 
Equipment Manufacturer 
Model 
 
Serial 
Number 
AV Receiver 
Harman International   
Industries, Incorporated 
AVR270/230 AN0138-0000005 
LCD Monitor 
TIANJIN  
SAMSUNG ELECTRONICS 
PU22WS YFE5HVRB300557W
USB Memory 
N/A 
N/A 
 
Headphone PHILIPS 
SHP2000   
Oscilloscope 
EZ Digital Co., Ltd. 
OS-5060A 
 
Speaker YAMAHA 
CORPORATION 
NS-E8900 
Z132461 
Laptop Computer 
Samsung Electronics Co., Ltd.
NT-RF510 
ZZVL93EB301744D 
AC Adapter 
Chicony Power   
Technology co., Ltd 
A10-090P1A 
CNBA4400215 
ADON812700N8 
Switch N/A 
N/A 
N/A 
Termination N/A 
N/A 
N/A 
Dummy Load 
N/A 
N/A 
N/A 
 
 
Anam Electronics Co., Ltd.                                    Page 7 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
3.6 Interface Cable 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.7 Test Set-up Drawing 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Connection of EUT 
Connection Terminal 
Cable Data 
Power Cable 
AC Public Network 
1.9 m unshielded cable 
HDMI OUT 
LCD Monitor 
1.5 m shielded cable 
NETWORK 
Switch 
3.0 m unshielded cable 
USB USB 
Memory 
Direct 
FM Antenna 
Termination 
Direct 
Headphone 
Headphone 
2.0 m shielded cable 
HDMI IN x 8 EA 
Cable open 
1.5 m unshielded cable 
SPEAKERS Dummy 
Load 
1.5 m shielded cable 
SPEAKERS 
SPEAKER 
1.5 m shielded cable 
SPEAKERS 
Oscilloscope 
1.5 m shielded cable 
ZONE 2 OUT, REC OUT,   
DIGITAL AUDIO COAXIAL 
Termination 
1.5 m shielded cable 
ANALOG AUDIO IN,   
SUB WOOFER PRE-OUT 
Termination 
1.5 m shielded cable 
COMPONENT VIDEO, COMPOSITE 
Termination 
1.5 m shielded cable 
TRIGGER OUT, IR OUT 
Cable open 
1.5 m unshielded cable 
ZONE 2 IR IN, IR IN 
Cable open 
1.5 m unshielded cable 
RS-232 
Laptop Computer 
1.5 m shielded cable 
 
EUT 
Laptop  
Computer 
LCD 
Monitor 
Speaker 
Oscilloscope
Dummy  
Load
Headphone 
Termination 
Cable open
AC Adapter 
Switch
I/O Cable 
Power Cable 
Termination : FM Antenna, ZONE 2 OUT, REC OUT,   
DIGITAL AUDIO COAXIAL, ANALOG AUDIO IN,   
SUB WOOFER PRE-OUT, COMPONENT VIDEO,   
COMPOSITE 
Cable open : HDMI IN, TRIGGER OUT, IR OUT, ZONE 2 IR IN, IR IN 
RS-232 
HDMI OUT
SPEAKERS
USB Memory 
SPEAK
ERS
 
FM Antenna   
(Termination) 
Network
 
 
Anam Electronics Co., Ltd.                                    Page 8 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
4. Evaluation Of Performance 
 
4.1 Functions Monitored During Immunity Tests   
 
      In order to verify acceptable performance by the EUT during the applied tests, the following   
   functions were monitored: 
Performance of EUT according to the manufacturer specifications   
 
4.2 Function Tested After Immunity Tests   
 
      The following function tests were conducted to verify correct performance by the EUT before and   
   after each test:  
      Performance of EUT according to the manufacturer specifications   
 
4.3 Performance Criteria 
 
4.3.1 Compliance criteria for EN 55024 
 
Criteria A 
The equipment shall continue to operate as intended without operator intervention. No degradation of   
performance or loss of function is allowed below a performance level specified by the manufacturer   
when the equipment is used as intended. The performance level may be replaced by a permissible loss   
of performance. If the minimum performance level or the permissible performance loss is not specified   
by the manufacturer, then either of these may be derived from the product description and   
documentation, and by what the user may reasonably expect from the equipment if used as intended.   
 
Criteria B 
After the test, the equipment shall continue to operate as intended without operate intervention. No   
degradation of performance or loss of function is allowed, after the application of the phenomena   
below a performance level specified by the manufacturer, when the equipment is used as intended. The   
performance level may be replaced by a permissible loss of performance. 
During the test, degradation of performance is allowed. However, no change of operating state or   
stored data is allowed to persist after the test. 
If the minimum performance level (or the permissible performance loss) is not specified by the   
manufacturer, then either of these may be derived from the product description and documentation, and   
by what the user may reasonably expect from the equipment if used as intended. 
 
Criteria C 
Loss of function is allowed, provided the function is self-recoverable, or can be restored by the   
operation of the controls by the user in accordance with the manufacturer’s instructions. 
Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall   
not be lost.   
 
Page of 57
Display