DOWNLOAD Harman Kardon AVR 270 (serv.man4) Service Manual ↓ Size: 2.49 MB | Pages: 57 in PDF or view online for FREE

Model
AVR 270 (serv.man4)
Pages
57
Size
2.49 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-270-sm4.pdf
Date

Harman Kardon AVR 270 (serv.man4) EMC - CB Certificate ▷ View online

 
Anam Electronics Co., Ltd.                                    Page 33 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
9.3 Test Log   
 
① ITE mode (USB, Network Internet Radio mode) 
No. Point 
Voltage  Coupling 
Result 
(Pass/Fail)
- HCP, 
VCP 
 4 kV 
Contact Discharge 
Pass 
1 Enclosure 
 4 kV 
Contact Discharge 
Pass 
2 Screws 
 4 kV 
Contact Discharge 
Pass 
3 Network 
 4 kV 
Contact Discharge 
Pass 
4 FM 
Antenna 
 4 kV 
Contact Discharge 
Pass 
5 RCA 
 4 kV 
Contact Discharge 
Pass 
6 Enclosure 
(Front) 
 2 kV,  4 kV,  8 kV 
Air Discharge 
Pass 
7 Buttons 
 2 kV,  4 kV,  8 kV 
Air Discharge 
Pass 
8 USB 
 2 kV,  4 kV,  8 kV 
Air Discharge 
Pass 
 
② AV mode (DVD mode) 
No. Point 
Voltage  Coupling 
Result 
(Pass/Fail)
- HCP, 
VCP 
 4 kV 
Contact Discharge 
Pass 
1 Enclosure 
 4 kV 
Contact Discharge 
Pass 
2 Screws 
 4 kV 
Contact Discharge 
Pass 
3 Network 
 4 kV 
Contact Discharge 
Pass 
4 FM 
Antenna 
 4 kV 
Contact Discharge 
Pass 
5 RCA 
 4 kV 
Contact Discharge 
Pass 
6 Enclosure 
(Front) 
 2 kV,  4 kV,  8 kV 
Air Discharge 
Pass 
7 Buttons 
 2 kV,  4 kV,  8 kV 
Air Discharge 
Pass 
8 USB 
 2 kV,  4 kV,  8 kV 
Air Discharge 
Pass 
 
Comment/Performance 
No operation errors were detected during and after the discharges. 
Result 
    Compliant 
 
 
Anam Electronics Co., Ltd.                                    Page 34 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
9.4 Discharges Points 
 
 
 
 
 
[Front] 
 
 
[Rear]
 
Air discharge 
Contact discharge
 
Anam Electronics Co., Ltd.                                    Page 35 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
10. Radiated Electromagnetic Field 
 
10.1 Test Procedure 
 
The tests were performed at 3 m distance in an anechoic chamber.   
        For floor-standing equipment, the EUT was mounted a non-conducting support 0.1 m above the 
        supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. 
        The EUT was exposed to the field from different angles, normally 0º, 90º, 180º, 270º and at both   
horizontal and vertical polarization (antenna height 1.55 m) 
        A signal level of 3 V / m, 80 % AM modulated with a 1 kHz sine wave was applied in the frequency   
range 80 – 1000 MHz. 
Instrumentation used during this session:
   
Instruments Manufacturer 
Model 
Serial number
Due to Calibration 
POWER METER 
Rohde & Schwarz 
NRP 
102491 
2013.04 
SIGNAL 
GENERATOR 
Rohde & Schwarz 
SMB 100A 
103440 
2013.04 
Power Amplifier 
BONN Elektronik 
BLWA 0810- 
160/50D 
107808B 2013.04 
Power Amplifier 
BONN Elektronik 
BLWA 0810- 
160/100D 
107808A 2013.04 
TRIPOD MOBILE 
Rohde & Schwarz 
HL046Z1 
100112 
EMS- ANTENNA 
Rohde & Schwarz 
HL046 
100054 
AUTO 
POLARISATION 
SWITCH 
Rohde & Schwarz 
N/A 
 
10.2 Test Parameters 
 
Port: 
Enclosure 
Test Engineer: 
Wonho Son 
Applied Standard: 
EN 55024:1998+A1:2001+A2:2003 
 
Basic Standard: 
EN 61000-4-3:2006+A1:2008+A2:2010 
Performance Criteria: 
Performance Results : 
Dwell Time: 
3 s 
Modulation: 
80 % AM (1 kHz) 
Frequency Step: 
1 % 
Test Level: 
3 V / m 
Frequency Range: 
80-1000 MHz 
 
 
 
10.3 Test Log 
       
ITE mode (USB, Network Internet Radio mode)
 
Frequency Range 
(MHz) 
Position 
(Angle) 
Polarity 
(H or V) 
Field Strength
(V / m) 
Modulation 
Result 
(Pass/Fail)
80-1000 
Front 
80 % AM (1 kHz) 
Pass 
80-1000 Rear H 
3 80 
AM 
(1 
kHz) 
Pass 
80-1000 
Right 
80 % AM (1 kHz) 
Pass 
80-1000 
Left 
80 % AM (1 kHz) 
Pass 
80-1000 
Front 
80 % AM (1 kHz) 
Pass 
80-1000 Rear V 
3 80 
AM 
(1 
kHz) 
Pass 
80-1000 
Right 
80 % AM (1 kHz) 
Pass 
80-1000 
Left 
80 % AM (1 kHz) 
Pass 
 
        Comment/Performance 
No operation errors were detected during and after the exposures. 
Result   
  Compliant
 
Anam Electronics Co., Ltd.                                    Page 36 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
11. RF e.m. field keyed carrier : S5 
 
11.1 Test Procedure 
 
The tests were performed at 3 m distance in an anechoic chamber.   
        For floor-standing equipment, the EUT was mounted non-conducting support 0.1 m above the 
        supporting plane. For tabletop equipment, the EUT was located on a wooden table 0.8 m above the floor. 
        The EUT was exposed to the field from different angles, normally 0º, 90º, 180º, 270º and at both   
horizontal and vertical polarization(antenna height 1.55 m) 
        A signal level of 3 V / m, duty cycle 1/8 pulse modulated with a 217 Hz sine wave was applied in the   
frequency range 900 MHz. During the test the 1 kHz unwanted noise level comes from the speaker was   
detected using microphone and selected level meter. 
        Instrumentation used during this session:
   
Instruments Manufacturer 
Model 
Serial number
Due to Calibration 
POWER METER 
Rohde & Schwarz 
NRP 
102491 
2013.04 
SIGNAL 
GENERATOR 
Rohde & Schwarz 
SMB 100A 
103440 
2013.04 
Power Amplifier 
BONN Elektronik 
BLWA 0810- 
160/50D 
107808B 2013.04 
Power Amplifier 
BONN Elektronik 
BLWA 0810- 
160/100D 
107808A 2013.04 
TRIPOD MOBILE 
Rohde & Schwarz 
HL046Z1 
100112 
EMS- ANTENNA 
Rohde & Schwarz 
HL046 
100054 
AUTO 
POLARISATION 
SWITCH 
Rohde & Schwarz 
N/A 
 
11.2 Test Parameters 
 
Port: 
Enclosure 
Test Engineer: 
Wonho Son 
Applied Standard: 
EN 55020:2007+A11:2011 
Basic Standard: 
EN 61000-4-3:2006+A1:2008+A2:2010 
Performance Criteria: 
Performance Results :
Test Level: 
3 Vrms 
Dwell Time: 
3 s 
Frequency Step: 
1 % 
Modulation: 
Duty Cycle 1/8 PM@217Hz
Frequency Range: 
900 MHz   
 
 
 
11.3 Test Log 
 
AV mode (DVD mode)
 
Frequency  
Range (MHz) 
Position 
(Angle) 
Polarity
(H/V) 
Field Strength 
(V / m) 
Modulation 
Result 
(Pass/Fail)
900 Front 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
900 Rear 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
900 Right 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
900 
Left H 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
900 
Front V 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
900 
Rear V 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
900 
Right V 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
900 
Left V 
Duty Cycle 1 / 8 PM@217 Hz 
Pass 
 
Comment/Performance 
No operation errors were detected during and after the exposures. 
Result 
          Compliant
Page of 57
Display