Anam Electronics Co., Ltd. Page 37 of 57
AVR270/230
EMC Test Report
Reference No.: NK-12-E-569
12. Fast Transients/Burst
12.1 Test Procedure
The minimum area of the ground reference plane is 1 m x 1 m, and connected to earth via a low impedance
connection.
The EFT/Burst generator was located on the ground reference plane.
The EUT was located 0.1 m above the ground reference plane and the length of power line between the
EFT/Burst generator and the EUT is 0.5 m.
The cable length between the EUT and the coupling device was as short as possible in the range 0.5 m to 3.0 m.
The test voltage was applied simultaneously between each of the power supply conductors and the
protective earth at the power supply.
Instrumentation used during this session:
Instruments Manufacturer
Model Serial number
Due to Calibration
EFT/Burst Simulator
Noiseken
FNS-AXⅡB50
0199B01147 2012.10
Clamp Noiseken
FNS-AXⅡB50
N/A 2012.10
12.2 Test Parameters
Port:
a.c. mains, LAN Test
Engineer:
Wonho Son
Applied Standards:
EN 55024:1998+A1:2001+A2:2003,
EN 55020:2007+A11:2011
Basic Standard:
EN 61000-4-4:2004+A1:2010
Duration:
120 s
Test Data
Tr/Th 5/50 ns
Fburst 5 kHz
Trep 300 ms
Performance Criteria: B
Performance Results :
A
12.3 Test Log
① ITE mode (USB, Network Internet Radio mode)
Line Voltage
Coupling
Inject Time
(sec)
Result
(Pass/Fail)
L1
1 kV
Direct 120
Pass
L2
1 kV
Direct 120
Pass
L1-L2
1 kV
Direct 120
Pass
LAN port
0.5 kV
Clamp 120
Pass
② AV mode (DVD mode)
Line Voltage
Coupling
Inject Time
(sec)
Result
(Pass/Fail)
L1
1 kV
Direct 120
Pass
L2
1 kV
Direct 120
Pass
L1-L2
1 kV
Direct 120
Pass
Comment/Performance
No operation errors were detected after the test.
Result
Compliant
Anam Electronics Co., Ltd. Page 38 of 57
AVR270/230
EMC Test Report
Reference No.: NK-12-E-569
13. Surge Pulse
13.1 Test Procedure
The surge generator was connected to earth via a low impedance connection. No presences of an
earth/reference plane is necessary. The surge test was applied to a.c. mains.
The surges were applied between neutral and ground, between each phase and ground and between the
phases.
For each level/line the surges were applied at stepped phase angles with 90º steps.
The differential mode surges were applied at ± 0.5 kV, ±1 kV Line-Neutral and Neutral-Line for
power ports.
The surges were applied with 1min intervals.
Instrumentation used during this session:
Instruments Manufacturer
Model
Serial number
Due to Calibration
Surge Simulator
Noiseken
LSS-6030
9099E00349
2012.10
13.2 Test Parameters
Port:
a.c. mains Test
Engineer:
Wonho Son
Applied Standards:
EN 55024:1998+A1:2001+A2:2003
Basic Standard:
EN 61000-4-5:2006
Test Data
Line to Neutral,
Neutral to Line
Performance Criteria:
B
Performance Results : A
13.3 Test Log
▶ITE mode (USB, Network Internet Radio mode)
Line Voltage Coupling Phase
Inject
(count)
Result
(Pass/Fail)
N-L
0.5 kV, 1 kV
Direct
0 ~ 360º / 90º step
5
Pass
L-N
0.5 kV, 1 kV
Direct
0 ~ 360º / 90º step
5
Pass
Comment/Performance
No operation errors were detected after the surge.
Result
Compliant
Anam Electronics Co., Ltd. Page 39 of 57
AVR270/230
EMC Test Report
Reference No.: NK-12-E-569
14. Immunity to Conducted Disturbances
14.1 Test Procedure
The tests were performed on a 2 m x 2 m ground reference plane. The EUT was located on a 0.1 m
isolating support. The current was injected to each single port separately. For a.c. ports, d.c. ports,
coaxial lines and 2- or 4 –lines balanced communication lines a coupling/decoupling network was used
to inject. On other multiple signal cables a capacitive coupling clamp (EM Clamp) was used for
injection.
Each signal level of 3V (emf), 80 % AM modulated with a 1 kHz sine wave were applied in the
frequency range 150 kHz – 80 MHz.
Instrumentation used during this session:
Instruments Manufacturer
Model
Serial number
Due to Calibration
Continuous
Wave Simulator
emtest
CWS 500 C S1
V0706102236
2013.04
CDN FCC
NCDN-M3-16A
2020
2013.04
CDN FCC
NCDN-M3-16A
2021
2013.04
CDN FCC
NCDN-M2-16A
2012
2013.04
INJECTION
PROBE
FCC NEM-32 411 2013.04
14.2 Test Parameters
Port:
a.c. mains, LAN Test
Engineer:
Wonho Son
Applied Standards:
EN 55024:1998+A1:2001+A2:2003
Basic Standard:
EN 61000-4-6:2009
Frequency Step:
1 %
Frequency Range:
0.15-80 MHz
Dwell Time:
3 s
Test Level:
3 V (emf)
Modulation:
80 % AM (1 kHz)
Performance Criteria:
A
Performance Results : A
14.3 Test Log
▶ITE mode (USB, Network Internet Radio mode)
Frequency
(MHz)
Point
Coupling
Field Strength
V (emf)
Modulation
Result
(Pass/Fail)
0.15-80
a.c. main power
CDN (M2)
3
80 % AM (1 kHz)
Pass
0.15-80
LAN
Clamp
3
80 % AM (1 kHz)
Pass
Comment/Performance
No operation errors were detected during and after the injection.
Result
Compliant
Anam Electronics Co., Ltd. Page 40 of 57
AVR270/230
EMC Test Report
Reference No.: NK-12-E-569
15. Voltage Dips and Interruption
15.1 Test Procedure
The dips/interruption test is only applicable to a.c. mains. The dips/interruptions were applied at zero
crossing. The presence of a reference plane and the configuration of EUT are not critical for this test.
The dips were applied with 100 % dip and a 30 % dip. EUT was given a 10 s interval between each dip
to recover.
Three-phase dips were applied at each individual voltage with one at a time (phase to neutral and phase to
phase).
The interruptions are 100 % dip-type. EUT was given a 10 s interval between each interruption to
recover. Three-phase interruptions were applied at all the three phases simultaneously.
Instrumentation used during this session:
Instruments Manufacture
Model
Serial number
Due to Calibration
AC Power Source
SCHAFFNER
PROFLINE2115-400
35000361
2012.10
15.2 Test Parameters
Port:
a.c. mains Test
Engineer:
Wonho Son
Applied Standards:
EN 55024:1998+A1:2001+A2:2003
Basic Standard:
EN 61000-4-11:2004
Voltage
Reduction
Duration
Performance
Criteria
Test Level:
30 % (dropout)
25 period
C
100 % (dropout)
0.5 period
B
100 % (interruption)
250 period
C
Performance Results : A, A , C
15.3 Dips/Interruptions Test Log
▶ITE mode (USB, Network Internet Radio mode)
Voltage Dip/Int.
%U
T
Duration Period of
the rated frequency
Phase
(˚)
Count
Result
(Pass/Fail)
30 %
25 period
0
3 T
Pass
100 %
0.5 period
0
3 T
Pass
100 %
250 period
0
3 T
Pass
Comment/Performance
During the interruption, a power of EUT was turned off.
But after the interruption, the EUT was recovered by operator’s intervention.
Result
Compliant