Anam Electronics Co., Ltd.                                    Page 37 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
12. Fast Transients/Burst 
 
12.1 Test Procedure 
 
The minimum area of the ground reference plane is 1 m x 1 m, and connected to earth via a low impedance   
connection.  
The EFT/Burst generator was located on the ground reference plane. 
The EUT was located 0.1 m above the ground reference plane and the length of power line between the   
EFT/Burst generator and the EUT is 0.5 m. 
        The cable length between the EUT and the coupling device was as short as possible in the range 0.5 m to 3.0 m. 
The test voltage was applied simultaneously between each of the power supply conductors and the   
protective earth at the power supply. 
Instrumentation used during this session: 
Instruments Manufacturer 
Model  Serial number
Due to Calibration
EFT/Burst Simulator
Noiseken 
FNS-AXⅡB50
0199B01147 2012.10
 
Clamp Noiseken 
FNS-AXⅡB50
N/A 2012.10
 
 
12.2 Test Parameters 
 
Port: 
a.c. mains, LAN Test 
Engineer: 
Wonho Son 
Applied Standards: 
EN 55024:1998+A1:2001+A2:2003, 
 
 
EN 55020:2007+A11:2011 
 
Basic Standard: 
EN 61000-4-4:2004+A1:2010 
Duration: 
120 s 
 
 
Test Data 
Tr/Th    5/50 ns 
Fburst  5 kHz 
Trep  300 ms 
Performance Criteria:  
Performance Results :
 
12.3 Test Log 
 
  ITE mode (USB, Network Internet Radio mode) 
Line Voltage 
Coupling 
Inject Time 
(sec) 
Result  
(Pass/Fail) 
L1 
 1 kV 
Direct 120 
Pass 
L2 
 1 kV 
Direct 120 
Pass 
L1-L2 
 1 kV 
Direct 120 
Pass 
LAN port 
 0.5 kV 
Clamp 120 
Pass 
 
  AV mode (DVD mode) 
Line Voltage 
Coupling 
Inject Time 
(sec) 
Result  
(Pass/Fail) 
L1 
 1 kV 
Direct 120 
Pass 
L2 
 1 kV 
Direct 120 
Pass 
L1-L2 
 1 kV 
Direct 120 
Pass 
   
 
 
        Comment/Performance 
No operation errors were detected after the test. 
        Result 
    Compliant
 
Anam Electronics Co., Ltd.                                    Page 38 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
13. Surge Pulse 
 
13.1 Test Procedure 
       
 
The surge generator was connected to earth via a low impedance connection. No presences of an   
          earth/reference plane is necessary. The surge test was applied to a.c. mains. 
The surges were applied between neutral and ground, between each phase and ground and between the   
phases. 
          For each level/line the surges were applied at stepped phase angles with 90º steps. 
The differential mode surges were applied at  ± 0.5 kV, ±1 kV Line-Neutral and Neutral-Line for   
power ports. 
The surges were applied with 1min intervals. 
     Instrumentation used during this session:  
Instruments Manufacturer 
Model 
Serial number 
Due to Calibration 
Surge Simulator 
Noiseken 
LSS-6030 
9099E00349 
2012.10 
 
13.2 Test Parameters 
 
Port: 
a.c. mains   Test 
Engineer: 
Wonho Son 
Applied Standards: 
EN 55024:1998+A1:2001+A2:2003 
 
Basic Standard: 
EN 61000-4-5:2006 
 
Test Data 
Line to Neutral, 
Neutral to Line 
 
Performance Criteria: 
Performance Results :  
 
13.3 Test Log 
 
ITE mode (USB, Network Internet Radio mode) 
Line Voltage Coupling Phase 
Inject  
(count) 
Result 
(Pass/Fail)
N-L 
 0.5 kV,  1 kV 
Direct 
0 ~ 360º / 90º step 
Pass 
L-N 
 0.5 kV,  1 kV 
Direct 
0 ~ 360º / 90º step 
Pass 
 
Comment/Performance 
No operation errors were detected after the surge. 
            Result 
      Compliant 
 
Anam Electronics Co., Ltd.                                    Page 39 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
14. Immunity to Conducted Disturbances 
 
14.1 Test Procedure 
       
 
The tests were performed on a 2 m x 2 m ground reference plane. The EUT was located on a 0.1 m   
          isolating support. The current was injected to each single port separately. For a.c. ports, d.c. ports,   
  coaxial lines and 2- or 4 –lines balanced communication lines a coupling/decoupling network was used   
          to inject. On other multiple signal cables a capacitive coupling clamp (EM Clamp) was used for   
     injection. 
Each signal level of 3V (emf), 80 % AM modulated with a 1 kHz sine wave were applied in the   
     frequency range 150 kHz – 80 MHz. 
     Instrumentation used during this session: 
Instruments Manufacturer 
Model 
Serial number
Due to Calibration 
Continuous  
Wave Simulator 
emtest 
CWS 500 C S1 
V0706102236 
2013.04 
CDN FCC 
NCDN-M3-16A 
2020 
2013.04 
CDN FCC 
NCDN-M3-16A 
2021 
2013.04 
CDN FCC 
NCDN-M2-16A 
2012 
2013.04 
INJECTION 
PROBE 
FCC NEM-32 411  2013.04 
 
 14.2 Test Parameters 
 
Port: 
a.c. mains, LAN Test 
Engineer: 
Wonho Son 
Applied Standards: 
EN 55024:1998+A1:2001+A2:2003 
 
Basic Standard: 
EN 61000-4-6:2009 
 
Frequency Step: 
1 % 
 
 
Frequency Range: 
0.15-80 MHz 
Dwell Time: 
3 s 
Test Level: 
3 V (emf) 
Modulation: 
80 % AM (1 kHz) 
Performance Criteria: 
Performance Results :  
 
14.3 Test Log 
 
ITE mode (USB, Network Internet Radio mode) 
Frequency 
(MHz) 
Point 
Coupling 
Field Strength 
V (emf) 
Modulation 
Result 
(Pass/Fail)
0.15-80 
a.c. main power 
CDN (M2)
80 % AM (1 kHz) 
Pass 
0.15-80 
LAN 
Clamp 
80 % AM (1 kHz) 
Pass 
 
          Comment/Performance 
No operation errors were detected during and after the injection. 
          Result 
          Compliant 
 
Anam Electronics Co., Ltd.                                    Page 40 of 57 
AVR270/230
 
EMC Test Report 
Reference No.: NK-12-E-569 
 
15. Voltage Dips and Interruption 
 
15.1 Test Procedure 
 
The dips/interruption test is only applicable to a.c. mains. The dips/interruptions were applied at zero 
        crossing. The presence of a reference plane and the configuration of EUT are not critical for this test. 
The dips were applied with 100 % dip and a 30 % dip. EUT was given a 10 s interval between each dip   
to recover. 
Three-phase dips were applied at each individual voltage with one at a time (phase to neutral and phase to   
phase). 
        The interruptions are 100 % dip-type. EUT was given a 10 s interval between each interruption to   
recover. Three-phase interruptions were applied at all the three phases simultaneously. 
Instrumentation used during this session: 
Instruments Manufacture 
Model 
Serial number 
Due to Calibration 
AC Power Source 
SCHAFFNER 
PROFLINE2115-400
35000361 
2012.10
 
 
15.2 Test Parameters 
 
Port: 
a.c. mains Test 
Engineer: 
Wonho Son 
Applied Standards: 
EN 55024:1998+A1:2001+A2:2003 
 
Basic Standard: 
EN 61000-4-11:2004 
 
 Voltage 
Reduction 
Duration 
Performance 
Criteria 
Test Level: 
30 % (dropout) 
25 period 
 
100 % (dropout) 
0.5 period 
 
100 % (interruption) 
250 period 
Performance Results :  A, A , C 
 
 
 
15.3 Dips/Interruptions Test Log 
 
ITE mode (USB, Network Internet Radio mode)
 
Voltage Dip/Int. 
%U
T
 
Duration Period of   
the rated frequency 
Phase 
(˚
Count 
Result 
(Pass/Fail) 
30 % 
25 period 
3 T 
Pass 
100 % 
0.5 period 
3 T 
Pass 
100 % 
250 period 
3 T 
Pass 
 
Comment/Performance 
During the interruption, a power of EUT was turned off. 
But after the interruption, the EUT was recovered by operator’s intervention. 
Result 
          Compliant 
 
 
 
Page of 57