Test Report
No.:
DR50120306G
5.4.3 TEST RESULT
1) Test Data:
June 05, 2003
Temperature: 25 ℃
Temperature: 25 ℃
Humidity: 56 %
Barometric: 988 mbar
Barometric: 988 mbar
2) Uncertainty (95%,Confidence) : ±10%
3) Result (AC Power Port)
Line Result
Remarks
L1
500V PASS
1KV PASS
1KV PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
L2
500V PASS
1KV PASS
1KV PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
L1-L2
500V PASS
1KV PASS
1KV PASS
During the test, I heard something noise.
After testing, It works well.
After testing, It works well.
Table 3 : AC Power lines, Positive/Negative Polarity
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 14 of 19
Test Report
No.:
DR50120306G
APPENDIX 1 --- TEST SETUP PHOTOGRAPH ---
1. Electrostatic discharge
2. Radiated radio-frequency electromagnetic field
3. Electrical fast transient / burst
4. EUT
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 15 of 19
Test Report
No.:
DR50120306G
Set up for Electrostatic discharge
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 16 of 19
Test Report
No.:
DR50120306G
Set up for Radiated radio-frequency electromagnetic field
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080