Harman Kardon AVR 235 (serv.man2) EMC - CB Certificate ▷ View online
DIGITAL EMC CO., LTD.
Page 9 of 19
Test Report
No.:
DR50120306G
5.2.3
ESD TEST POINT AND RESULT
1) Test Data:
June 05, 2003
Temperature: 25 ℃
Temperature: 25 ℃
Humidity: 56 %
Barometric: 988 mbar
Barometric: 988 mbar
2) Uncertainty (95%,Confidence) : ± 5%
3) Point and Result
No. Position
Kind of Discharge Result Remarks
①
Enclosure(front)
Air
PASS
No disturbance of function
②
Cable
Air
PASS
No disturbance of function
③
LED Air PASS
During the test,
I heard something noise.
I heard something noise.
After testing, It works well.
④
Enclosure
(left,right,top,rear)
(left,right,top,rear)
Contact
PASS
No disturbance of function
⑤
Port
Contact
PASS
No disturbance of function
⑥
Screw
Contact
PASS
No disturbance of function
⑦
HCP / VCP
Contact
PASS
No disturbance of function
Table 1 : ESD, Positive / Negative Polarity
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 10 of 19
Test Report
No.:
DR50120306G
5.3 Radiated radio-frequency electromagnetic field
RESULT : Pass
5.3.1 Measurement Procedure
The immunity against radio-frequency electromagnetic fields was tested in accordance to
EN55020:1994+A11:1996+A12,A13,A14:1999. The test set-up was make according to
EN61000-4-3: 1996+A1: 1998+A2:2001 in semi-anechoic chamber. The EUT has bees
placed in center of a wooden turntable. The height of this table was 0.8m. The field strength
was monitored by an isotropic sensor during the complete test.
The isotropic sensor was located beside the equipment. The antenna has been orientated for
both horizontal and vertical polarization. The distance between antenna the equipment under
testing was at least 3m. The tests have been performed with the antenna facing each of the
four side of the EUT.
EN55020:1994+A11:1996+A12,A13,A14:1999. The test set-up was make according to
EN61000-4-3: 1996+A1: 1998+A2:2001 in semi-anechoic chamber. The EUT has bees
placed in center of a wooden turntable. The height of this table was 0.8m. The field strength
was monitored by an isotropic sensor during the complete test.
The isotropic sensor was located beside the equipment. The antenna has been orientated for
both horizontal and vertical polarization. The distance between antenna the equipment under
testing was at least 3m. The tests have been performed with the antenna facing each of the
four side of the EUT.
Radio-frequency electromagnetic field. Keyed carrier.
Severity level
: 2
Field strength
: 3V/m
Frequency range
: 900㎒ ±5㎒
Duty cycle
: 50%
Rep. frequency
: 200 Hz
Performance criterion
: A
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 11 of 19
Test Report
No.:
DR50120306G
5.3.2 List of Test and Measurement Instruments
Radiated radio-frequency electromagnetic field
Name of
Instrument
Type Serial
No
Manufacturer
Next Cal.
Date
Control computer
Pentium 750MHz
N/A
SAMSUNG
-
Software TEMTO-RS Ver.4.3en
TSJ
-
Electric Field Sensor
(~5KHz,~800V/m)
HI-6005 107823
Holaday
2004.01
Signal
Generator(3.3GHz)
SML03
100647
Rohde &y Schwarz
2004.03
Power Meter
NRVD
100403
Rohde &y Schwarz
2004.03
RF Switch Matrix
(~12GHz,500W)
RFM-S3A2CIL 2075
TSJ
2004.05
Antenna(75M~1.5G
Hz,1kW)
VULP9118 754
Schwarzbeck 2004.01
Horn Antenna
(0.8G~5GHz)
(0.8G~5GHz)
BBHA9120A 322
Schwarzbeck 2004.03
RF Power Amplifier
(~1GHz,250W)
CMC250 FO44-0620
IFI
2004.04
RF Power Amplifier
(1-3GHz,25W)
5055R 1007
Ophir
RF 2004.04
5.3.3 TEST RESULT
1) Test Data:
June 09, 2003
Temperature: 28 ℃
Temperature: 28 ℃
Humidity: 59 %
Barometric: 990 mbar
Barometric: 990 mbar
2) Uncertainty (95%,Confidence level, k=2.28) : ±1.6dB
3) Result
Result
Position
Horizontal Vertical
Remark
Front Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Right Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Left Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Back Side
PASS
PASS
Equipment operated as intended.
No disturbance of function
No disturbance of function
Table 2 : Radiated radio-frequency electromagnetic field
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080
DIGITAL EMC CO., LTD.
Page 12 of 19
Test Report
No.:
DR50120306G
5.4 Electrical fast transient / burst
RESULT : Pass
5.4.1 Measurement Procedure
The immunity against fast transients was tested in accordance to EN55020:1994 +A11:1996
+ A12,A13,A14:1999. on all lines which length may exceed 3m according to the
manufacturers specification. Test set-up with capacitive clamp and fast transient noise
generator was according to EN61000-4-4: 1995+A1:2001.
The EUT has been placed on a wooden table 0.8m above the reference ground plane.
The reference ground plane exceeded the projected geometry of the EUT and the capacitive
clamp by more than 20cm. The clamp has placed directly on the reference ground plane.
The un-used signal connector of the clamp has been terminated with a 50Ω resistor.
The distance between the EUT and all other conductive structures. Except the ground plane
beneath the EUT was more than 0.5m. The distance between clamp and EUT was about 30cm.
beneath the EUT was more than 0.5m. The distance between clamp and EUT was about 30cm.
Severity level
: 2 (AC Power port)
Test voltage
: 0.5, 1 (kV)
Polarity :
Negative/
positive
Repetition frequency
: 5㎑
Performance criterion
: B
5.4.2 List of Test and Measurement Instruments
Electrical fast transient / burst
Name of
Instrument
Model No
Serial No
Manufacturer
Next Cal.
Date
BEST EMC
BEST EMCV2.7 200122-043SC
SCHAFFNER
2003.09
PERSONAL
COMPUTER
Emachines/AC
50035 045 00056
COMPUTOWN
N/A
EFT Clamp
CDN8014
17332
SCHAFFNER
N/A
#683-3,Yubang-Dong, Yongin-Si,Kyunggi-Do,Korea,449-080