Page 37 of 52 
Report No.: 232174
 
TRF No. IEC60065K 
 
No. 
Component 
Fault 
Duration 
of the test
Other results 
(include description) 
dT (K) / Component 
dT (K) 
Permitted
dT(K) ***)
10.  
*), #) 
Q914 
(D to S) 
SC 
10 min 
Normal operated. 
The operating mode changed to 
LOW mode after 3 min 30 s. 
FI stabilised at 1.05 A. 
NCD.  No hazard.  
N/A N/A 
11.  
*), #) 
IC99 
(pin 3 to 1) 
SC 
10 min 
Normal operated. 
The operating mode changed to 
LOW mode after 3 min 10 s. 
FI stabilised at 1.05 A. 
NCD.  No hazard.  
N/A N/A 
12 
*), #) 
D921 
(A to C) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
13 
*), #) 
C944 
SC 
30 min 
Unit shut down immediately. 
FI changed between 0.05 A and  
0.07 A periodically. 
NCD.  No hazard. 
N/A N/A 
14 
*), #) 
C984 
SC 
30 min 
Unit shut down immediately. 
FI changed between 0.05 A and  
0.07 A periodically. 
NCD.  No hazard. 
N/A N/A 
15 
*), #) 
D942 
(A to C) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
16 
**), #) 
D942 
(A to C) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
17 
*), #) 
C928 
SC 
2 hr 
All speakers output off immediately. 
FI changed between 0.27 A and 
2.15 A periodically. 
Measured highest temperature; 
1) TF93 coil 
2) TF93 core and stabilised. 
Dielectric strength test. 
No hazard.  
 
 
 
 
78.9 
73.6 
 
 
 
 
 
 
140 ****) 
150 
 
 
*) Tested voltage 264V 
**) Tested voltage 198V 
Apparatus mode:  
#) HIGH mode 
##) LOW mode 
***) Temperature rise limits for tropical climate is 10 K less.
 
****) Minus (-) 10K applied for thermo-couple method for windings
 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 
Page 38 of 52 
Report No.: 232174
 
TRF No. IEC60065K 
 
No. 
Component 
Fault 
Duration 
of the test
Other results 
(include description) 
dT (K) / Component 
dT (K) 
Permitted
dT(K) ***)
18 
*), #) 
C937 SC 1 
hr 
20 min 
All speakers output off immediately. 
FI changed between 0.27 A and 
2.11 A periodically. 
Measured highest temperature; 
1) TF93 coil 
2) TF93 core and stabilised. 
Dielectric strength test. 
No hazard.  
 
 
 
 
77.2 
73.6 
 
 
 
 
140 ****) 
150 
19 
*), #) 
D950 
(A to C) 
SC 
10 min 
Normal operated. 
The operating mode changed to 
LOW mode after 3 min 30 s. 
FI stabilised at 1.05 A. 
NCD.  No hazard.  
N/A N/A 
20 
*), #) 
PC93 
(pin 3 to 4) 
SC 
10 min 
All speakers output off immediately. 
FI stabilised at 0.27 A. 
NCD.  No hazard. 
N/A N/A 
21 
*), #) 
PC93 
(pin 1 to 2) 
SC 
10 min 
All speakers output off immediately. 
FI stabilised at 0.27 A. 
NCD.  No hazard. 
N/A N/A 
22 
*), #) 
PC96 
(pin 3 to 4) 
SC 
10 min 
Normal operated. 
The operating mode changed to 
LOW mode after 3 min 30 s. 
FI stabilised at 1.05 A. 
NCD.  No hazard.  
N/A N/A 
23 
*), #) 
PC96 
(pin 1 to 2) 
SC 
10 min 
All speakers output off immediately. 
FI stabilised at 0.27 A. 
NCD.  No hazard. 
N/A N/A 
24 
*), #) 
PC92 
(pin 3 to 4) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
25 
*), #) 
PC92 
(pin 1 to 2) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
IC91, R923, R922, R990 and D921 
damaged.  No hazard. 
N/A N/A 
26 
*), #) 
PC95 
(pin 1 to 2) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
*) Tested voltage 264V 
**) Tested voltage 198V 
Apparatus mode:  
#) HIGH mode 
##) LOW mode 
***) Temperature rise limits for tropical climate is 10 K less.
 
****) Minus (-) 10K applied for thermo-couple method for windings
 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 
Page 39 of 52 
Report No.: 232174
 
TRF No. IEC60065K 
 
No. 
Component 
Fault 
Duration 
of the test
Other results 
(include description) 
dT (K) / Component 
dT (K) 
Permitted
dT(K) 
27 
*), #) 
PC95 
(pin 3 to 4) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
28 
*), #) 
PC94 
(pin 3 to 4) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
29 
*), #) 
PC94 
(pin 1 to 2) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
30 
*), #) 
PC91 
(pin 3 to 4) 
SC 
10 min 
Normal operated. 
The operating mode changed to 
LOW mode after 3 min 20 s. 
FI stabilised at 1.05 A. 
NCD.  No hazard.  
N/A N/A 
31 
*), #) 
PC91 
(pin 1 to 2) 
SC 
10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
32 
*), #) 
C401 SC 10 min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
33 
*), #) 
C152 SC 10 min 
Unit shut down immediately. 
FI changed between 0.05 A and 
0.07 A periodically. 
NCD.  No hazard.  
N/A N/A 
34 
*), #) 
C452 SC 10 min 
All speakers output and FL display 
off immediately. 
FI stabilised at 0.49 A. 
NCD.  No hazard.  
N/A N/A 
35 
*), ##) 
Q804 
(C to E) 
SC 10 
min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
36 
*), ##) 
Q804 
(C to B) 
SC 10 
min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
37 
*), ##) 
C808 SC 10 
min 
Normal operated. 
FI stabilised at 1.05 A. 
NCD.  No hazard.  
N/A N/A 
*) Tested voltage 264V 
**) Tested voltage 198V 
Apparatus mode:  
#) HIGH mode 
##) LOW mode 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 
Page 40 of 52 
Report No.: 232174
 
TRF No. IEC60065K 
 
No. 
Component 
Fault 
Duration 
of the test
Other results 
(include description) 
dT (K) / Component 
dT (K) 
Permitted
dT(K) 
38 
*), #) 
Q803 
(C to E) 
SC 10 
min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
Q804 damaged.  No hazard. 
N/A N/A 
39 
*), #) 
Q803 
(C to B) 
SC 10 
min 
Unit shut down immediately. 
FI stabilised at 0.06 A. 
NCD.  No hazard. 
N/A N/A 
40 
*), #) 
C807 SC 10 
min 
Normal operated. 
The operating mode changed to 
LOW mode after 3 min 30 s. 
FI stabilised at 1.05 A. 
NCD.  No hazard.  
N/A N/A 
41 
*), #) 
DB91 
(AC to “+”) 
SC 1 
s  F901 fuse opened immediately. 
No hazard.  
N/A N/A 
42 
**), #) 
DB91 
(AC to “+”) 
SC 1 
s  F901 fuse opened immediately. 
No hazard.  
N/A N/A 
43 
*), #) 
DB91 
(AC to “-”) 
SC 1 
s  F901 fuse opened immediately. 
No hazard.  
N/A N/A 
44 
*), #) 
C901 SC 1 
s  F901 fuse opened immediately. 
No hazard.  
N/A N/A 
45 
**), #) 
C901 SC 1 
s  F901 fuse opened immediately. 
No hazard.  
N/A N/A 
46 
*), #) 
D944 
(A to C) 
SC 10 
min 
Normal operated. 
The operating mode changed to 
LOW mode after 3 min 30 s. 
FI stabilised at 1.06 A. 
NCD.  No hazard.  
N/A N/A 
47 
*), #) 
Q901 
(pin 2 to 1) 
SC 1 
s  F901 fuse opened immediately. 
Q901 and IC93 damaged. 
No hazard.  
N/A N/A 
48 
*), #) 
Q901 
(pin 2 to 3) 
SC 1 
s  F901 fuse opened immediately. 
No hazard.  
N/A N/A 
49 
*), #) 
D901 
(A to C) 
SC 
1 s 
F901 fuse opened immediately. 
D902 damaged.  No hazard.  
N/A N/A 
50 
*), #) 
C902 
SC 
1 s 
F901 fuse opened immediately. 
D902 damaged.  No hazard.  
N/A N/A 
*) Tested voltage 264V 
**) Tested voltage 198V 
Apparatus mode:  
#) HIGH mode 
##) LOW mode 
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current 
 
Page of 108