Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-171-sm5.pdf
Date

Harman Kardon AVR 171 (serv.man5) EMC - CB Certificate ▷ View online

Page 29 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
20.2 Fire 
enclosure 
 
 
N/A 
20.2.1 Potential 
ignition 
sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
No voltage > 4kV (peak) 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled  
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
Page 30 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 Marking 
and 
instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
Not intended for outdoor use 
N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION 
NETWORKS 
 
 
Complies with IEC 62151 clause 1  
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
Page 31 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used  
No electronic flash apparatus 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used  
 
N/A 
L. 7 
Heating under normal operating conditions 
 
N/A 
L7.1.5 & 
L11.2.7 
Lithium batteries meet permissible temp rise in 
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC 
60086-4  
No lithium batteries 
N/A 
L. 9 
Electric shock hazard under normal operating 
conditions 
Not flash synchroniser 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE  
 
N/A 
L.10 Insulation 
requirements 
 
N/A 
L. 10.3.2 
High frequency puls ignition  
 
N/A 
L. 12 
Mechanical strength 
 
N/A 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test  
 
N/A 
L. 14 
Components 
 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions  
 
N/A 
L. 20 
Resistance to fire 
 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE  
 
N/A 
 
 
 
 
Page 32 of 52 
Report No.: 232174
 
TRF No. IEC60065K 
 
7.1 
TABLE: temperature rise measurements:  
 
Power consumption in the OFF/Stand-by mode of 
the functional switch (W)  ........................................ : 
Less than 0.48 W 
— 
Operating Condition / Status 
Standby mode;  
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) 
Pout (W) 
1 220  50  0.05 
0.40 
— 
— 
2 240  50  0.04 
0.45 
— 
— 
3 220  60  0.05 
0.44 
— 
— 
4 240  60  0.05 
0.48 
— 
— 
 
 
 
 
 
 
 
1 kHz input signal with maximum non-clipped output mode with loaded 5V/2.1 A through USB terminal 
(Measured at “HIGH mode” of the transformer output, TF93 - see summary of testing for details); 
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) 
Pout (W) 
5 264  50  2.41 
378.5 
F) 12.48 x 2 ch 
SB) 12.32 x 2 ch 
S) 12.64 x 2 ch  
C) 12.55 x 1 ch 
F) 25.96 x 2 ch 
SB) 25.30 x 2 ch  
S) 26.63 x 2 ch 
C) 26.25 x 1 ch 
6 264  60  2.35 
377.5 
 
 
 
 
 
 
 
1 kHz input signal with 1/8 of maximum non-clipped output mode with loaded 5V/2.1 A through USB terminal 
(Measured at “HIGH mode” of the transformer output, TF93 - see summary of testing for details);  
Cond. 
Un (V) 
Hz 
In (A) 
Pn (W) 
Uout (V) 
Pout (W) 
7 198  50  2.60 
301.7 
F) 4.42 x 2 ch 
SB) 4.35 x 2 ch 
S) 4.47 x 2 ch 
C) 4.44 x 1 ch 
F) 3.25 x 2 ch 
SB) 3.16 x 2 ch 
S) 3.33 x 2 ch 
C) 3.28 x 1 ch 
8 220  50  2.38 
298.4 
9 240  50  2.15 
298.0 
10 264  50  1.91 
295.2 
11 198  60  2.55 
301.0 
12 220  60  2.30 
297.8 
13 240  60  2.10 
295.3 
14 264  60  1.86 
292.1 
 
 
 
 
 
 
 