DOWNLOAD Harman Kardon AVR 171 (serv.man5) Service Manual ↓ Size: 6.35 MB | Pages: 108 in PDF or view online for FREE

Model
AVR 171 (serv.man5)
Pages
108
Size
6.35 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-171-sm5.pdf
Date

Harman Kardon AVR 171 (serv.man5) EMC - CB Certificate ▷ View online

Page 21 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 
N/A 
14.5 Protective 
devices 
 
 
 
Protective devices used within their ratings  
Thermal cut-outs and fuse 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
Certified protective devices 
applied (thermal cut-outs and 
fuse) 
See appended table, list of  
critical components. 
14.5.1.1 
a) Thermal cut-outs separately approved  
TS92 thermal cut-out is 
approved component 
according to IEC 60730-1. 
See appended table, list of  
critical components. 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
No thermal links 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
No thermal device re-settable 
by soldering 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
Fuse is approved according 
to IEC 60127. 
See appended table, list of  
critical components. 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : 
Marked on PCB adjacent to 
fuse as; 
F901: T 6.3A H 250V 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : 
No possible to connect fuses  
in parallel. 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
No replacement of fuse 
possible by hand 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
PTC thermistor, F201 for USB 
port, comply with IEC 60730-1 
 
PTC devices (15 W) category V-1 or better  
< 15W 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
Only standard fuse and 
protector used. 
N/A 
14.6 
Switches  
No mains switch.  
N/A 
Page 22 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
 
N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 
N/A 
 
Switch controlling < 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
 
N/A 
 
Socket outlet current marking correct  
No mains socket-outlets 
N/A 
14.7 
Safety interlocks  
No safety interlocks 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
No voltage setting devices 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 
N/A 
14.9 
Motors 
No AC motors 
Brushless DC FAN motor only. 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
Only DC supplied. 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
The motor for fans are not 
adversely affected by oil or 
grease or other substances. 
Page 23 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
14.9.3 
Protection against moving parts  
The fans are placed inside the 
unit.  No access. 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 
N/A 
14.10 Batteries 
No 
batteries 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 Optocouplers 
 
Optocouplers are approved 
components. 
 
External creepage/clearance 
distances are min. 7.7 mm.  
Internal creepage/clearance 
distances are min. 6.0 mm, or 
thermal cycling test is covered 
by SEMKO 
DTI: Min. 0.4 mm.  
See appended table, list of  
critical components. 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
 
b) Comply with IEC 60747-5-5:2007 
 
N/A 
 
Alternative to a) and b) optocoupler comply with 13.8  
N/A 
14.12 
Surge suppression varistors  
 
 
Comply with IEC 61051-2  
Varistor, VT91 and VT92 
comply with IEC 61051-2. 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
A certified varistor used 
N/A 
 
Page 24 of 52 
Report No.: 232174 
 
IEC 60065 
Clause Requirement 
Test 
Result 
Verdict 
 
TRF No. IEC60065K 
 
15 Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Approved cord set and 
appliance inlet provided. 
See appended table, list of 
critical components, and 
summary of testing. 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
No mains socket outlets 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
No mains socket outlets 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
See below. 
 
No risk of insertion in mains socket-outlets  
Only RCA, Antenna, Optical, 
Network, HDMI and mini jacks 
terminals used. 
Banana plug type speaker 
terminal also used, but they 
are accepted due to below 
note. 
 
Note)  
Banana plug type speaker 
terminals are blocked in their 
axial holes to prevent use of 
plugs that can make 
permanent contact with a 
mains socket outlet 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
No sockets indicated with 
the symbol 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
Not adaptors used 
N/A 
15.2 
Provision for protective earthing 
 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II equipment. 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 
 at 25 A  ................... :   
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
Appliance inlet applied 
N/A 
Page of 108
Display